Comparison of low-dose and standard-dose helical CT in the evaluation of pulmonary nodules

Abstract. The purpose of this study was to investigate the diagnostic accuracy of low-dose helical computed tomography by comparing the number of nodules detected at low- and standard-dose CT. The prospective study included 25 patients who were referred to CT scan for the assessment of pulmonary metastases. All patients underwent CT examinations at both standard- (200 mA, 120 kV, collimation 5 mm, table feed 10 mm per rotation) and low-dose (50 mA, 120 kV, collimation 5 mm, table feed 10 mm per rotation). The number of nodules detected at each protocol was recorded. The size of the nodules was measured electronically and categorized as <3, 3–4.9, 5–6.9, 7–9.9, and ≥10 mm. Finally, the nodules detected at only standard- or low-dose CT were assessed for the underlying causes of discrepancy. In 25 patients, 533 nodules were detected at standard-dose, whereas 518 nodules were observed at low-dose CT. There were no statistically significant differences in the number of nodules detected at standard- or low-dose CT (p>0.05). Four hundred ninety-one (87.7%) nodules were detected at both standard- or low-dose CT, 42 (7.5%) nodules were observed only at standard-dose CT, and 27 (4.8%) nodules were seen only at low-dose CT. The sensitivity of low-dose CT was 92.5% for all nodules, 88.1% for nodules <5 mm, and 97.4% for nodules ≥5 mm. No significant image artifact interfering with nodule detection was observed at low-dose CT. The low-dose CT protocol used in this study provided images of adequate quality; thus, it can be used reliably in the detection or exclusion of pulmonary nodules.

[1]  B. Archer,et al.  The AAPM/RSNA physics tutorial for residents. Typical patient radiation doses in diagnostic radiology. , 1999, Radiographics : a review publication of the Radiological Society of North America, Inc.

[2]  K S Lee,et al.  CT of the chest: minimal tube current required for good image quality with the least radiation dose. , 1995, AJR. American journal of roentgenology.

[3]  H Rusinek,et al.  Pulmonary nodule detection: low-dose versus conventional CT. , 1998, Radiology.

[4]  J E Aldrich,et al.  Chronic infiltrative lung disease: comparison of diagnostic accuracies of radiography and low- and conventional-dose thin-section CT. , 1994, Radiology.

[5]  D. McCauley,et al.  Low-dose CT of the lungs: preliminary observations. , 1990, Radiology.

[6]  A. Dwyer,et al.  Matchmaking and McNemar in the comparison of diagnostic modalities. , 1991, Radiology.

[7]  J Zoetelief,et al.  Survey of CT techniques and absorbed dose in various Dutch hospitals. , 1997, The British journal of radiology.

[8]  J. Cooke,et al.  A comparison of radiation doses to the breast in computed tomographic chest examinations for two scanning protocols. , 1989, Clinical radiology.

[9]  H. Ohmatsu,et al.  Peripheral lung cancer: screening and detection with low-dose spiral CT versus radiography. , 1996, Radiology.

[10]  A. Leung,et al.  Simulated dose reduction in conventional chest CT: validation study. , 1997, Radiology.

[11]  T. Vogl,et al.  Radiation exposure in spiral computed tomography. Dose distribution and dose reduction. , 1999, Investigative radiology.

[12]  B. Wall,et al.  Revised radiation doses for typical X-ray examinations. Report on a recent review of doses to patients from medical X-ray examinations in the UK by NRPB. National Radiological Protection Board. , 1997, The British journal of radiology.

[13]  D. Nosske,et al.  Effective doses to members of the public from the diagnostic application of ionizing radiation in Germany , 1997, European Radiology.

[14]  K S Lee,et al.  Low-Dose, Volumetric Helical CT: Image Quality, Radiation Dose, and Usefulness for Evaluation of Bronchiectasis , 2000, Investigative radiology.

[15]  N. Müller,et al.  Low-dose high-resolution CT of lung parenchyma. , 1991, Radiology.

[16]  T M Yelbuz,et al.  Pulmonary nodules: experimental and clinical studies at low-dose CT. , 1999, Radiology.

[17]  T. Westermeier,et al.  Pulmonary nodules: detection with low-dose vs conventional-dose spiral CT , 1998, European Radiology.

[18]  Bernd Hamm,et al.  Low-dose spiral CT: applicability to paediatric chest imaging , 1999, Pediatric Radiology.

[19]  W. Kalender,et al.  Evaluation of section sensitivity profiles and image noise in spiral CT. , 1992, Radiology.