Inverted Pedicled Internal Limiting Membrane Flap Attached to an Optic Disc with Autologous Blood Clot for Large Macular Holes

Purpose An inverted ILM flap might be accidentally separated from the retina or sucked away during surgery for large macular holes (MHs). This article is to determine the efficacy of a new inverted pedicled internal limiting membrane (ILM) flap attached to an optic disc with an autologous blood clot (ABC) technique for the treatment of large MHs. Methods An inverted pedicled ILM flap connected to the optic disc with ABC was used to treat 12 consecutive patients with significant macular holes (>600 m). The ILM was first peeled off around MH as a semidiameter of about 1.5 diameters of the optic disc. The superior residual ILM was used to produce a pedicled ILM flap that was connected to the optic disc and was later inverted to cover the MH. The macular hole was covered with a repositioned flap larger than 2 MH diameters in an inverted way. ABC was used to fasten the flap, followed by fluid-air exchange with air or C3F8 as tamponade. Spectral domain-optical coherence tomography (SD-OCT) and best-corrected visual acuity (BCVA) were performed at each postoperative follow-up. Results The mean aperture and base macular hole diameters were 737.9 ± 109.6 µm (range, 607–982 µm) and 1244.3 ± 227.4 µm (range, 975–1658 µm). All macular holes (100%) were closed after a single surgery without intraoperative or postoperative complications related to the ILM transposition technique. At the last postoperative visit, we found one eye with a U-shaped closure, three eyes with W-shaped closures, and eight eyes with V-shaped closures. No postoperative flap closures were noted in all cases. The preoperative mean BCVA was 1.5 ± 0.3 (range, 1.1–2.0). After a mean follow-up of 5.3 ± 4.8 (range, 3–16) months, the postoperative mean BCVA was 0.8 ± 0.2 (range, 0.6–1.1), and the difference was statistically significant (p < 0.05). Conclusion This novel technique is safe and suitable for large MHs and can be an alternative option for accidental ILM flap loss during other inverted ILM flap operations.

[1]  Wei-Chi Wu,et al.  Single-layer Inverted Internal Limiting Membrane Flap Versus Conventional Peel for Small- or Medium-sized Full-thickness Macular Holes. , 2021, American journal of ophthalmology.

[2]  P. Xie,et al.  Minimal internal limiting membrane peeling with ILM flap technique for idiopathic macular holes: a preliminary study , 2020, BMC Ophthalmology.

[3]  Chung-May Yang,et al.  EARLY AND LATE MACULAR CHANGES AFTER THE INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE FOR A FULL-THICKNESS MACULAR HOLE. , 2020, Retina.

[4]  I. Wong,et al.  Treatment of large, chronic and persistent macular hole with internal limiting membrane transposition and tuck technique , 2020, International Journal of Retina and Vitreous.

[5]  Wei-Chi Wu,et al.  Refractory macular hole repaired by autologous retinal graft and blood clot , 2018, BMC Ophthalmology.

[6]  P. Xie,et al.  Non-inverted pedicle internal limiting membrane transposition for large macular holes , 2018, Eye.

[7]  Z. Michalewska,et al.  MECHANISM OF “FLAP CLOSURE” AFTER THE INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE , 2017, Retina.

[8]  Y. Morizane,et al.  The Role of Inverted Internal Limiting Membrane Flap in Macular Hole Closure. , 2017, Investigative ophthalmology & visual science.

[9]  Peiquan Zhao,et al.  Novel Surgical Technique of Peeled Internal Limiting Membrane Reposition for Idiopathic Macular Holes , 2017, Retina.

[10]  A. Ebneter,et al.  Modification of the Inverted Internal Limiting Membrane Flap Technique for the Treatment of Chronic and Large Macular Holes. , 2016, Retina.

[11]  Sung Who Park,et al.  Perfluoro-n-octane Assisted Free Internal Limiting Membrane Flap Technique for Recurrent Macular Hole , 2015, Retina.

[12]  R. Adelman,et al.  TEMPORAL INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE VERSUS CLASSIC INVERTED INTERNAL LIMITING MEMBRANE FLAP TECHNIQUE: A Comparative Study , 2015, Retina.

[13]  Sung Who Park,et al.  Perfluoro-n-Octane–Assisted Single-Layered Inverted Internal Limiting Membrane Flap Technique for Macular Hole Surgery , 2014, Retina.

[14]  R. Adelman,et al.  Inverted internal limiting membrane flap technique for large macular holes. , 2010, Ophthalmology.

[15]  P. Jen,et al.  Echo duration selectivity of the bat varies with pulse–echo amplitude difference , 2008, Neuroreport.

[16]  S. Kang,et al.  Types of macular hole closure and their clinical implications , 2003, The British journal of ophthalmology.

[17]  J. Sipperley,et al.  Macular hole surgery with internal-limiting membrane peeling and intravitreous air. , 1999, Ophthalmology.

[18]  C. Eckardt,et al.  [Removal of the internal limiting membrane in macular holes. Clinical and morphological findings]. , 1997, Der Ophthalmologe : Zeitschrift der Deutschen Ophthalmologischen Gesellschaft.

[19]  J D Gass,et al.  Reappraisal of biomicroscopic classification of stages of development of a macular hole. , 1995, American journal of ophthalmology.

[20]  R. Wendel,et al.  Vitreous surgery for idiopathic macular holes. Results of a pilot study. , 1991, Archives of ophthalmology.