Angiographic analysis of blood flow modification in cerebral aneurysm models with a new asymmetric stent
暂无分享,去创建一个
Daniel R. Bednarek | Stephen Rudin | Kenneth R. Hoffmann | Ciprian N. Ionita | Zhou Wang | Adam B. Paxton | K. Hoffmann | S. Rudin | D. Bednarek | Zhou Wang | C. Ionita | A. Paxton
[1] L. Guterman,et al. Combined use of stents and coils to treat experimental wide-necked carotid aneurysms: preliminary results. , 1994, AJNR. American journal of neuroradiology.
[2] F Asakura,et al. Evaluation of intraaneurysmal blood velocity by time-density curve analysis and digital subtraction angiography. , 1998, AJNR. American journal of neuroradiology.
[3] K R Hoffmann,et al. Determination of instantaneous and average blood flow rates from digital angiograms of vessel phantoms using distance-density curves. , 1991, Investigative radiology.
[4] Daniel R. Bednarek,et al. Measurement of flow modification in phantom aneurysm model: comparison of coils and a longitudinally and axially asymmetric stent--initial findings. , 2004, Radiology.
[5] F Viñuela,et al. Natural history of the neck remnant of a cerebral aneurysm treated with the Guglielmi detachable coil system. , 2000, Journal of neurosurgery.
[6] Baruch B. Lieber,et al. Particle Image Velocimetry Assessment of Stent Design Influence on Intra-Aneurysmal Flow , 2002, Annals of Biomedical Engineering.
[7] Yuichi Murayama,et al. Guglielmi detachable coil embolization of cerebral aneurysms: 11 years' experience. , 2003, Journal of neurosurgery.
[8] Ciprian N Ionita,et al. Particle image velocimetry (PIV) evaluation of flow modification in aneurysm phantoms using asymmetric stents , 2004, SPIE Medical Imaging.
[9] G. Geremia,et al. Embolization of experimentally created aneurysms with intravascular stent devices. , 1992, AJNR. American journal of neuroradiology.
[10] R. Close,et al. X-ray videodensitometric methods for blood flow and velocity measurement: a critical review of literature. , 2000, Medical physics.
[11] Eric A Hoffman,et al. Influence of gravity on radiographic contrast material-based measurements of regional blood flow distribution. , 2003, Academic radiology.
[12] K. Nozaki,et al. Prevention of rat cerebral aneurysm formation by inhibition of nitric oxide synthase. , 2000, Circulation.
[13] A. Rhoton,et al. Microsurgical anatomy of the anterior perforating arteries. , 1984, Journal of neurosurgery.
[14] Stephen Rudin,et al. Micro-angiographic detector with fluoroscopic capability , 2002, SPIE Medical Imaging.
[15] A L Rhoton,et al. Microsurgical anatomy of the upper basilar artery and the posterior circle of Willis. , 1977, Journal of neurosurgery.
[16] R. Sayers,et al. Endovascular repair of abdominal aortic aneurysms , 1994, The Lancet.
[17] Chander Sadasivan,et al. Angiographic quantification of contrast medium washout from cerebral aneurysms after stent placement. , 2002, AJNR. American journal of neuroradiology.
[18] C M Strother,et al. Computer modeling of intracranial saccular and lateral aneurysms for the study of their hemodynamics. , 1995, Neurosurgery.