Exposure to MRI-related magnetic fields and vertigo in MRI workers

Objectives Vertigo has been reported by people working around magnetic resonance imaging (MRI) scanners and was found to increase with increasing strength of scanner magnets. This suggests an association with exposure to static magnetic fields (SMF) and/or motion-induced time-varying magnetic fields (TVMF). This study assessed the association between various metrics of shift-long exposure to SMF and TVMF and self-reported vertigo among MRI workers. Methods We analysed 358 shifts from 234 employees at 14 MRI facilities in the Netherlands. Participants used logbooks to report vertigo experienced during the work day at the MRI facility. In addition, personal exposure to SMF and TVMF was measured during the same shifts, using portable magnetic field dosimeters. Results Vertigo was reported during 22 shifts by 20 participants and was significantly associated with peak and time-weighted average (TWA) metrics of SMF as well as TVMF exposure. Associations were most evident with full-shift TWA TVMF exposure. The probability of vertigo occurrence during a work shift exceeded 5% at peak exposure levels of 409 mT and 477 mT/s and at full-shift TWA levels of 3 mT and 0.6 mT/s. Conclusions These results confirm the hypothesis that vertigo is associated with exposure to MRI-related SMF and TVMF. Strong correlations between various metrics of shift-long exposure make it difficult to disentangle the effects of SMF and TVMF exposure, or identify the most relevant exposure metric. On the other hand, this also implies that several metrics of shift-long exposure to SMF and TVMF should perform similarly in epidemiological studies on MRI-related vertigo.

[1]  Hans Kromhout,et al.  Exposure, health complaints and cognitive performance among employees of an MRI scanners manufacturing department , 2006, Journal of magnetic resonance imaging : JMRI.

[2]  Oliver Kraff,et al.  A large‐scale study on subjective perception of discomfort during 7 and 1.5 T MRI examinations , 2011, Bioelectromagnetics.

[3]  Frank de Vocht,et al.  Health complaints among nurses working near MRI scanners--a descriptive pilot study. , 2011, European journal of radiology.

[4]  Dale C. Roberts,et al.  MRI Magnetic Field Stimulates Rotational Sensors of the Brain , 2011, Current Biology.

[5]  Stuart Crozier,et al.  Analysis and Measurements of Magnetic Field Exposures for Healthcare Workers in SelectedMR Environments , 2008, IEEE Transactions on Biomedical Engineering.

[6]  F. Leisch,et al.  FlexMix Version 2: Finite Mixtures with Concomitant Variables and Varying and Constant Parameters , 2008 .

[7]  W. Teeuwisse,et al.  Subject tolerance of 7 T MRI examinations , 2013, Journal of magnetic resonance imaging : JMRI.

[8]  A. Raftery Bayesian Model Selection in Social Research , 1995 .

[9]  Brian L. Day,et al.  On the Vertigo Due to Static Magnetic Fields , 2013, PloS one.

[10]  H. Akaike A new look at the statistical model identification , 1974 .

[11]  Thomas A. Houpt,et al.  Behavioral effects on rats of motion within a high static magnetic field , 2011, Physiology & Behavior.

[12]  David Kriebel,et al.  Exposure and dose modelling in occupational epidemiology , 2007, Occupational and Environmental Medicine.

[13]  Friedrich Leisch,et al.  Fitting finite mixtures of generalized linear regressions in R , 2007, Comput. Stat. Data Anal..

[14]  W. Soichi,et al.  Guidelines for limiting exposure to electric fields induced by movement of the human body in a static magnetic field and by time-varying magnetic fields below 1 Hz. , 2014, Health physics.

[15]  Klaus Scheffler,et al.  Multicenter Study of Subjective Acceptance During Magnetic Resonance Imaging at 7 and 9.4 T , 2014, Investigative radiology.

[16]  Keith R Thulborn,et al.  Vital signs and cognitive function are not affected by 23‐sodium and 17‐oxygen magnetic resonance imaging of the human brain at 9.4 T , 2010, Journal of magnetic resonance imaging : JMRI.

[17]  Penny Gowland,et al.  Comment on ICNIRP guidelines for limiting exposure to electric fields induced by movement of the human body in a static magnetic field and by time-varying magnetic fields below 1 Hz. , 2014, Health physics.

[18]  James C. Smith,et al.  Behavioral Effects of High-Strength Static Magnetic Fields on Rats , 2003, The Journal of Neuroscience.

[19]  F. Leisch FlexMix: A general framework for finite mixture models and latent class regression in R , 2004 .

[20]  Stuart Crozier,et al.  Exposure to static and time-varying magnetic fields from working in the static magnetic stray fields of MRI scanners: a comprehensive survey in the Netherlands. , 2014, The Annals of occupational hygiene.

[21]  R. Bowtell,et al.  Magnetic‐field‐induced vertigo: A theoretical and experimental investigation , 2007, Bioelectromagnetics.

[22]  Oliver Kraff,et al.  Subjective acceptance of 7 Tesla MRI for human imaging , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[23]  Hans Kromhout,et al.  Occupational exposure of healthcare and research staff to static magnetic stray fields from 1.5–7 Tesla MRI scanners is associated with reporting of transient symptoms , 2014, Occupational and Environmental Medicine.