Assessment of power quality for line frequency coreless induction furnaces

This paper presents a study about power quality problems generated by line frequency coreless induction furnaces. We analyzed a furnace with 12.5 t capacity of cast-iron. The measurements have been made in the primary of the furnace transformer, on the MV line, using the CA8334 three-phase power quality analyser. Experimental results emphasized the presence of harmonics and interharmonics in the phase voltages and harmonics in the currents absorbed from the MV network. Further to harmonic analysis of the measured signals, we have been proposed some optimization methods for operation of analyzed furnace, in such way to comply with the European norms of Electromagnetic Compatibility (EMC).

[1]  Geraldo F. Burani,et al.  Application of modelling and computer simulation for the development of a test setup for calibration of power quality measurement transducers for high voltage networks , 2008 .

[2]  Mehdi Monadi,et al.  Harmonic Estimation in Power Systems Using Adaptive Perceptrons Based on a Genetic Algorithm , 2007 .

[3]  Ching-Tzong Su,et al.  Optimal Size and Location of Capacitors Placed on a Distribution System , 2008 .

[4]  Francesco Muzi Real-time voltage control to improve automation and quality in power distribution , 2008 .

[5]  Caius Panoiu,et al.  Simulation results on the currents harmonics mitigation on the railway station line feed , 2007 .

[6]  Francesco Muzi,et al.  Improvements in power quality and efficiency with a new AC/DC high current converter , 2008 .

[7]  T.B. Sekara,et al.  Optimal Reactive Compensators in Power Systems Under Asymmetrical and Nonsinusoidal Conditions , 2008, IEEE Transactions on Power Delivery.

[8]  Reza Kianinezhad,et al.  Fuzzy Logic Controlled Adaptive Active Power Filter for Harmonics Minimization and Reactive Power Compensation under Fast Load Variation , 2008 .

[9]  Valery Rudnev,et al.  Handbook of Induction Heating , 2002 .

[10]  Mihaela Osaci,et al.  Simulation result about harmonics filtering using measurement of some electrical items in electrical installation on UHP EAF , 2008 .

[11]  W HOSNY,et al.  HARMONIC DISTORTION AND REACTIVE POWER COMPENSATION IN SINGLE PHASE POWER SYSTEMS USING ORTHOGONAL TRANSFORMATION STRATEGY , 2008 .

[12]  Chen Chen,et al.  Harmonic Mitigation of Residential Distribution System using a Novel Hybrid Active Power Filter , 2007 .

[13]  V. Agarwal,et al.  Optimum Control of Selective and Total Harmonic Distortion in Current and Voltage Under Nonsinusoidal Conditions , 2008, IEEE Transactions on Power Delivery.

[14]  Francisco C. De La Rosa Harmonics and Power Systems , 2006 .

[15]  Alexandru Bitoleanu,et al.  Harmonic current reduction in railway systems , 2008 .

[16]  K. Sandhu,et al.  Role of Reactive Power Source on Power Quality of Three-Phase Self-Excited Induction Generator , 2008 .

[17]  B. Dobrucky,et al.  Harmonic distortion and reactive power compensation in single phase power systems using orthogonal transformation technique , 2007, 2007 42nd International Universities Power Engineering Conference.

[18]  Henri Foch,et al.  Radiated and conducted interferences in induction heating equipment: characteristics and remedies , 2002 .

[19]  Neville R. Watson,et al.  Power System Quality Assessment , 2000 .