Intra-rater and inter-rater reliability of gait measurements with CODA mpx30 motion analysis system.

Variations between measurements of clinical outcomes sometimes result from observer errors and are not due to the therapeutic intervention. For the correct interpretation of clinical data it is, therefore, important to ascertain the reliability of the measurement methods used. In the present study we evaluated the test-retest and between observer reliability of gait measurements with the Cartesian Optoelectronic Dynamic Anthropometer (CODA mpx30) motion analysis system. Our findings suggest a better intra-rater and inter-rater reliability of kinetic than kinematic data. Disagreements between the investigators were most marked for the kinematic data, especially the hip angle, and disagreements were least for the spatio-temporal gait parameters. The poor reproducibility of kinematic variables may be due to problems with the accurate placement of markers on the surface anatomical landmarks.

[1]  M P Kadaba,et al.  Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[2]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[3]  D. Winter,et al.  Overall principle of lower limb support during stance phase of gait. , 1980, Journal of biomechanics.

[4]  J. Fleiss The design and analysis of clinical experiments , 1987 .

[5]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[6]  J. Fleiss,et al.  Intraclass correlations: uses in assessing rater reliability. , 1979, Psychological bulletin.

[7]  H. K. Ramakrishnan,et al.  Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait , 1989, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[8]  D. Wade,et al.  Measurement in neurological rehabilitation. , 1992, Current opinion in neurology and neurosurgery.

[9]  E. Zwick,et al.  Intrasubject repeatability of gait analysis data in normal and spastic children. , 2000, Clinical biomechanics.

[10]  David A. Winter,et al.  Biomechanics and Motor Control of Human Movement , 1990 .

[11]  D. Winter Kinematic and kinetic patterns in human gait: Variability and compensating effects , 1984 .

[12]  M. Stokes,et al.  Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses , 1998, Clinical rehabilitation.

[13]  M. Eliasziw,et al.  Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example. , 1994, Physical therapy.

[14]  C. Diss The reliability of kinetic and kinematic variables used to analyse normal running gait. , 2001, Gait & posture.