Near-unity nuclear polarization with an open-source 129Xe hyperpolarizer for NMR and MRI

Significance Lung diseases comprise the third leading cause of death in the United States and could benefit from new imaging modalities. “Hyperpolarized” xenon-129 can overcome the ordinarily weak MRI signals from low-density species in lung space or dissolved in tissue; however, clinical progress has been slowed by the difficulty in preparing large amounts of hyperpolarized xenon with high magnetization, as well as the cost and limited availability of xenon hyperpolarization devices. We describe a unique low-cost “open-source” xenon “hyperpolarizer,” characterize its ability to produce xenon-129 with high magnetization, and demonstrate its utility for human lung imaging. The exquisite NMR spectral sensitivity and negligible reactivity of hyperpolarized xenon-129 (HP129Xe) make it attractive for a number of magnetic resonance applications; moreover, HP129Xe embodies an alternative to rare and nonrenewable 3He. However, the ability to reliably and inexpensively produce large quantities of HP129Xe with sufficiently high 129Xe nuclear spin polarization (PXe) remains a significant challenge—particularly at high Xe densities. We present results from our “open-source” large-scale (∼1 L/h) 129Xe polarizer for clinical, preclinical, and materials NMR and MRI research. Automated and composed mostly of off-the-shelf components, this “hyperpolarizer” is designed to be readily implementable in other laboratories. The device runs with high resonant photon flux (up to 200 W at the Rb D1 line) in the xenon-rich regime (up to 1,800 torr Xe in 500 cc) in either single-batch or stopped-flow mode, negating in part the usual requirement of Xe cryocollection. Excellent agreement is observed among four independent methods used to measure spin polarization. In-cell PXe values of ∼90%, ∼57%, ∼50%, and ∼30% have been measured for Xe loadings of ∼300, ∼500, ∼760, and ∼1,570 torr, respectively. PXe values of ∼41% and ∼28% (with ∼760 and ∼1,545 torr Xe loadings) have been measured after transfer to Tedlar bags and transport to a clinical 3 T scanner for MR imaging, including demonstration of lung MRI with a healthy human subject. Long “in-bag” 129Xe polarization decay times have been measured (T1 ∼38 min and ∼5.9 h at ∼1.5 mT and 3 T, respectively)—more than sufficient for a variety of applications.

[1]  A. Jameson,et al.  Nuclear spin relaxation by intermolecular magnetic dipole coupling in the gas phase. 129Xe in oxygen , 1988 .

[2]  J. Brossel,et al.  Evidence for Rb‐Rare‐Gas Molecules from the Relaxation of Polarized Rb Atoms in a Rare Gas. Experimental Results , 1972 .

[3]  Gas-phase spin relaxation of 129 Xe , 2008 .

[4]  D. Yablonskiy,et al.  Hyperpolarized 3 He gas production and MR imaging of the lung , 2001 .

[5]  I. Ruset,et al.  Optical pumping system design for large production of hyperpolarized. , 2006, Physical review letters.

[6]  M. Mortuza,et al.  Spin-exchange optical pumping of high-density xenon-129 , 2003 .

[7]  A. Pines,et al.  Evidence of nonspecific surface interactions between laser-polarized xenon and myoglobin in solution. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[8]  B. M. Goodson,et al.  Nuclear magnetic resonance of laser-polarized noble gases in molecules, materials, and organisms. , 2002, Journal of magnetic resonance.

[9]  E. Chekmenev,et al.  A large volume double channel 1H-X RF probe for hyperpolarized magnetic resonance at 0.0475 T. , 2012, Journal of magnetic resonance.

[10]  M. Barlow,et al.  {sup 129}Xe-Cs (D{sub 1},D{sub 2}) versus {sup 129}Xe-Rb (D{sub 1}) spin-exchange optical pumping at high xenon densities using high-power laser diode arrays , 2011 .

[11]  H. Jänsch,et al.  129Xe on Ir(111): NMR study of xenon on a metal single crystal surface. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[12]  Chupp,et al.  Laser optical pumping of high-density Rb in polarized 3He targets. , 1994, Physical review. A, Atomic, molecular, and optical physics.

[13]  W. Happer,et al.  Efficiency of Spin Exchange between Rubidium Spins and Xe 129 Nuclei in a Gas , 1982 .

[14]  B. Saam,et al.  Collisional 3He and 129Xe frequency shifts in Rb-noble-gas mixtures. , 2011, Physical review letters.

[15]  Christian Hilty,et al.  Molecular Imaging Using a Targeted Magnetic Resonance Hyperpolarized Biosensor , 2006, Science.

[16]  S Chien,et al.  Tissue-blood partition coefficient for xenon: temperature and hematocrit dependence. , 1980, Journal of applied physiology: respiratory, environmental and exercise physiology.

[17]  K. Stupic,et al.  Exploring hyperpolarized 83Kr by remotely detected NMR relaxometry. , 2006, The Journal of chemical physics.

[18]  M. Solum,et al.  Gas-phase spin relaxation of Xe129 , 2008 .

[19]  M. Barlow,et al.  Interdependence of in-cell xenon density and temperature during Rb/129Xe spin-exchange optical pumping using VHG-narrowed laser diode arrays. , 2011, Journal of magnetic resonance.

[20]  T. Budinger,et al.  NMR of laser-polarized xenon in human blood. , 1996, Proceedings of the National Academy of Sciences of the United States of America.

[21]  E. Miron,et al.  Pressure broadening of Rb D 1 and D 2 lines by 3 He, 4 He, N 2 , and Xe: Line cores and near wings , 1997 .

[22]  Thomas G. Walker,et al.  129Xe-Xe molecular spin relaxation. , 2002, Physical review letters.

[23]  T. Walker,et al.  Spin-exchange optical pumping of noble-gas nuclei , 1997 .

[24]  M. Barlow,et al.  Generation of laser-polarized xenon using fiber-coupled laser-diode arrays narrowed with integrated volume holographic gratings. , 2009, Journal of magnetic resonance.

[25]  E E de Lange,et al.  MR imaging and spectroscopy using hyperpolarized 129Xe gas: Preliminary human results , 1997, Magnetic resonance in medicine.

[26]  W. Happer,et al.  Fast nuclear spin relaxation in hyperpolarized solid 129Xe. , 2002, Physical review letters.

[27]  B. Saam,et al.  Characterization of a low-pressure high-capacity X 129 e flow-through polarizer , 2009 .

[28]  Cates,et al.  Surface relaxation mechanisms of laser-polarized 129Xe. , 1995, Physical review letters.

[29]  Barton,et al.  Rb-129Xe spin-exchange rates due to binary and three-body collisions at high Xe pressures. , 1992, Physical review. A, Atomic, molecular, and optical physics.

[30]  Bastiaan Driehuys,et al.  High‐volume production of laser‐polarized 129Xe , 1996 .

[31]  U. Ruth,et al.  Production of nitrogen-free, hyperpolarized 129Xe gas , 1999 .

[32]  M. Barlow,et al.  Using frequency-narrowed, tunable laser diode arrays with integrated volume holographic gratings for spin-exchange optical pumping at high resonant fluxes and xenon densities , 2012 .

[33]  Eduard E de Lange,et al.  MRI of the lungs using hyperpolarized noble gases , 2002, Magnetic resonance in medicine.

[34]  K. Stupic,et al.  Hyperpolarized 131Xe NMR spectroscopy , 2011, Journal of magnetic resonance.

[35]  Bhavin B. Adhyaru,et al.  High capacity production of >65% spin polarized xenon-129 for NMR spectroscopy and imaging. , 2002, Journal of magnetic resonance.

[36]  K. Stupic,et al.  Exploring hyperpolarized Kr83 by remotely detected NMR relaxometry , 2006 .

[37]  H. Spiess,et al.  Mixture and dissolution of laser polarized noble gases: spectroscopic and imaging applications. , 2012, Progress in nuclear magnetic resonance spectroscopy.

[38]  Scott D. Swanson,et al.  Distribution and dynamics of laser‐polarized 129Xe magnetization in vivo , 1999 .

[39]  K. Knagge,et al.  A continuously recirculating optical pumping apparatus for high xenon polarization and surface NMR studies , 2004 .

[40]  Daniel Morgan,et al.  The Helium-3 Shortage: Supply, Demand, and Options for Congress , 2010 .

[41]  R. Welsh,et al.  Polarized 129Xe optical pumping/spin exchange and delivery system for magnetic resonance spectroscopy and imaging studies , 1999 .

[42]  M. Barlow,et al.  Comparative study of in situ N2 rotational Raman spectroscopy methods for probing energy thermalisation processes during spin-exchange optical pumping , 2014 .

[43]  Hiroto Hatabu,et al.  Hyperpolarized (129)Xe MRI: a viable functional lung imaging modality? , 2007, European journal of radiology.