Fundamentals of magnet-actuated droplet manipulation on an open hydrophobic surface.

We systematically investigate droplet movement, coalescence, and splitting on an open hydrophobic surface. These processes are actuated by magnetic beads internalized in an oil-coated aqueous droplet using an external magnet. Results are organized into an 'operating diagram' that describes regions of droplet stable motion, breakage, and release from the magnet. The results are explained theoretically with a simple model that balances magnetic, friction, and capillary-induced drag forces and includes the effects of particle type, droplet size, surrounding oil layer, surface tension, and viscosity. Finally, we discuss the implications of the results for the design of magnet-actuated droplet systems for applications such as nucleic acid purification, immunoassay and drug delivery.

[1]  Nicole Pamme,et al.  Magnetism and microfluidics. , 2006, Lab on a chip.

[2]  A. Manz,et al.  Micro total analysis systems. Recent developments. , 2004, Analytical chemistry.

[3]  Darwin R. Reyes,et al.  Micro total analysis systems. 1. Introduction, theory, and technology. , 2002, Analytical chemistry.

[4]  P. Domínguez-García,et al.  Motion of viscous drops on superhydrophobic surfaces due to magnetic gradients , 2008 .

[5]  M. Gijs,et al.  Droplet-based DNA purification in a magnetic lab-on-a-chip. , 2006, Angewandte Chemie.

[6]  R. Larson,et al.  Adsorption and elution characteristics of nucleic acids on silica surfaces and their use in designing a miniaturized purification unit. , 2008, Analytical biochemistry.

[7]  Yi Zhang,et al.  Catching bird flu in a droplet , 2007, Nature Medicine.

[8]  Ho-Young Kim,et al.  Sliding of liquid drops down an inclined solid surface. , 2002, Journal of colloid and interface science.

[9]  Nam-Trung Nguyen,et al.  High-throughput polymerase chain reaction in parallel circular loops using magnetic actuation. , 2008, Analytical chemistry.

[10]  Mitsuhiro Shikida,et al.  Using wettability and interfacial tension to handle droplets of magnetic beads in a micro-chemical-analysis system , 2006 .

[11]  Mitsuhiro Shikida,et al.  A palmtop-sized rotary-drive-type biochemical analysis system by magnetic bead handling , 2008 .

[12]  P. Gascoyne,et al.  Droplet-based chemistry on a programmable micro-chip. , 2004, Lab on a chip.

[13]  Nam-Trung Nguyen,et al.  Kinematics and deformation of ferrofluid droplets under magnetic actuation , 2007 .

[14]  R. Mukhopadhyay Diving into droplets. , 2006, Analytical chemistry.

[15]  Andreas Manz,et al.  Micro total analysis systems: latest achievements. , 2008, Analytical chemistry.

[16]  S. T. Picraux,et al.  Magnetic movement of biological fluid droplets , 2007 .

[17]  Mitsuhiro Shikida,et al.  On-chip polymerase chain reaction microdevice employing a magnetic droplet-manipulation system , 2008 .

[18]  Hiroshi Ito,et al.  Development of an enzymatic reaction device using magnetic bead-cluster handling , 2006 .

[19]  G. Whitesides The origins and the future of microfluidics , 2006, Nature.

[20]  J. M. Rallison,et al.  Sliding, slipping and rolling: the sedimentation of a viscous drop down a gently inclined plane , 2004, Journal of Fluid Mechanics.

[21]  R. Fair,et al.  An integrated digital microfluidic lab-on-a-chip for clinical diagnostics on human physiological fluids. , 2004, Lab on a chip.

[22]  U. Lehmann,et al.  Two dimensional magnetic manipulation of microdroplets on a chip , 2005, The 13th International Conference on Solid-State Sensors, Actuators and Microsystems, 2005. Digest of Technical Papers. TRANSDUCERS '05..

[23]  Nam-Trung Nguyen,et al.  Manipulation of ferrofluid droplets using planar coils , 2006 .

[24]  Darwin R. Reyes,et al.  Micro total analysis systems. 2. Analytical standard operations and applications. , 2002, Analytical chemistry.

[25]  Richard B. Fair,et al.  Digital microfluidics: is a true lab-on-a-chip possible? , 2007 .

[26]  Martin A. M. Gijs,et al.  On-chip antibody handling and colorimetric detection in a magnetic droplet manipulation system , 2007 .

[27]  Yi Zhang,et al.  Clockwork PCR including sample preparation. , 2008, Angewandte Chemie.

[28]  N. Nguyen,et al.  A circular ferrofluid driven microchip for rapid polymerase chain reaction. , 2007, Lab on a chip.

[29]  Tetsuo Ohashi,et al.  A simple device using magnetic transportation for droplet-based PCR , 2007, Biomedical microdevices.