A robust three-phase active power-factor-correction and harmonic reduction scheme for high power

This paper proposes a robust three-phase active power-factor-correction (PFC) and harmonic reduction scheme suitable for higher power applications. The proposed system is a unique combination of a low-kilovoltampere 12-pulse rectifier system with a single-phase boost PFC scheme to shape the input current to near sinusoidal waveshape. The voltampere rating of the active PFC converter is 0.05 pu and is not exposed to line transients under varying load conditions. The proposed system is suitable for utility interface of higher power rectifiers employed in power supplies and adjustable-speed drive systems which demand clean input power characteristics in the range of 1-500 kW. The proposed system is rugged and, in the event the active control were to fail, the system reverts to 12-pulse operation with fifth and seventh harmonic cancellation. Analysis and design of the system is examined in detail, and simulation and experimental results on a 10 kVA prototype are shown.

[1]  B. R. Pelly,et al.  Thyristor Phase-Controlled Converters and Cycloconverters: Operation, Control, and Performance , 1971 .

[2]  Johannes Schaefer,et al.  Rectifier circuits : theory and design , 1965 .

[3]  A. von Jouanne,et al.  Polyphase transformer arrangements with reduced kVA capacities for harmonic current reduction in rectifier type utility interface , 1995 .

[4]  Robert L. Steigerwald,et al.  An AC-to-DC Converter with High Quality Input Waveforms , 1983, IEEE Transactions on Industry Applications.

[5]  Prasad Enjeti,et al.  New 24-pulse diode rectifier systems for utility interface of high-power AC motor drives , 1997 .

[6]  Dushan Boroyevich,et al.  Review of high-performance three-phase power-factor correction circuits , 1997, IEEE Trans. Ind. Electron..

[7]  Shigeo Masukawa,et al.  New Method for Reducing Harmonics Involved in Input and Output of Rectifier with Interphase Transformer , 1986, IEEE Transactions on Industry Applications.

[8]  Earl Rhyne,et al.  A Three-Phase Off-Line Switching Power Supply with Unity Power Factor and Low TIF , 1986, INTELEC '86 - International Telecommunications Energy Conference.

[9]  Sewan Choi,et al.  A new active interphase reactor for 12-pulse rectifiers provides clean power utility interface , 1995 .

[10]  Phoivos D. Ziogas,et al.  An active power factor correction technique for three-phase diode rectifiers , 1989 .

[11]  P. W. Hammond A new approach to enhance power quality for medium voltage drives , 1995, Industry Applications Society 42nd Annual Petroleum and Chemical Industry Conference.

[12]  Guy Olivier,et al.  Novel Transformer Connection to Improve Current Sharing in High-Current DC Rectifiers , 1995, IEEE Transactions on Industry Applications.

[13]  J. Kolar,et al.  Space vector-based analytical analysis of the input current distortion of a three-phase discontinuous-mode boost rectifier system , 1993 .