A Track-Repeating Algorithm for Fast Monte Carlo Dose Calculations of Proton Radiotherapy

Abstract Monte Carlo codes are utilized for accurate dose calculations in proton radiation therapy research. While they are superior in accuracy to commonly used analytical dose calculations, they require significantly longer computation times. The aim of this work is to characterize a Monte Carlo track-repeating algorithm to increase computation speed without compromising dosimetric accuracy. The track-repeating approach reduced the CPU time required for a complete dose calculation in voxelized patient anatomy by more than two orders of magnitude, while on average reproducing the results from the traditional Monte Carlo approach within 4% dose difference and within 1-mm distance to agreement.

[1]  A. Brandl,et al.  Shielding variation effects for 250 MeV protons on tissue targets. , 2005, Radiation protection dosimetry.

[2]  M. Fippel,et al.  A Monte Carlo dose calculation algorithm for proton therapy. , 2004, Medical physics.

[3]  H Paganetti,et al.  Nuclear interactions in proton therapy: dose and relative biological effect distributions originating from primary and secondary particles. , 2002, Physics in medicine and biology.

[4]  A. Ferrari,et al.  FLUKA: A Multi-Particle Transport Code , 2005 .

[5]  Radhe Mohan,et al.  Can megavoltage computed tomography reduce proton range uncertainties in treatment plans for patients with large metal implants? , 2008, Physics in medicine and biology.

[6]  C. Ma,et al.  A particle track-repeating algorithm for proton beam dose calculation , 2005, Physics in medicine and biology.

[7]  A. Trofimov,et al.  4D Monte Carlo simulation of proton beam scanning: modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry , 2005, Physics in medicine and biology.

[8]  E. Hall The Impact of Protons on the Incidence of Second Malignancies in Radiotherapy , 2007, Technology in cancer research & treatment.

[9]  D. Low,et al.  A technique for the quantitative evaluation of dose distributions. , 1998, Medical physics.

[10]  R. Mohan,et al.  Monte Carlo simulations of the dosimetric impact of radiopaque fiducial markers for proton radiotherapy of the prostate , 2007, Physics in medicine and biology.

[11]  Radhe Mohan,et al.  Monte Carlo simulations for configuring and testing an analytical proton dose-calculation algorithm , 2007, Physics in medicine and biology.

[12]  E Pedroni,et al.  Monte Carlo dose calculations for spot scanned proton therapy , 2005, Physics in medicine and biology.

[13]  W. Newhauser,et al.  Virtual commissioning of a treatment planning system for proton therapy of ocular cancers. , 2005, Radiation protection dosimetry.