Iterative regularization in intensity-modulated radiation therapy optimization.

A common way to solve intensity-modulated radiation therapy (IMRT) optimization problems is to use a beamlet-based approach. The approach is usually employed in a three-step manner: first a beamlet-weight optimization problem is solved, then the fluence profiles are converted into step-and-shoot segments, and finally postoptimization of the segment weights is performed. A drawback of beamlet-based approaches is that beamlet-weight optimization problems are ill-conditioned and have to be regularized in order to produce smooth fluence profiles that are suitable for conversion. The purpose of this paper is twofold: first, to explain the suitability of solving beamlet-based IMRT problems by a BFGS quasi-Newton sequential quadratic programming method with diagonal initial Hessian estimate, and second, to empirically show that beamlet-weight optimization problems should be solved in relatively few iterations when using this optimization method. The explanation of the suitability is based on viewing the optimization method as an iterative regularization method. In iterative regularization, the optimization problem is solved approximately by iterating long enough to obtain a solution close to the optimal one, but terminating before too much noise occurs. Iterative regularization requires an optimization method that initially proceeds in smooth directions and makes rapid initial progress. Solving ten beamlet-based IMRT problems with dose-volume objectives and bounds on the beamlet-weights, we find that the considered optimization method fulfills the requirements for performing iterative regularization. After segment-weight optimization, the treatments obtained using 35 beamlet-weight iterations outperform the treatments obtained using 100 beamlet-weight iterations, both in terms of objective value and of target uniformity. We conclude that iterating too long may in fact deteriorate the quality of the deliverable plan.

[1]  D K Smith,et al.  Numerical Optimization , 2001, J. Oper. Res. Soc..

[2]  A. Brahme,et al.  Optimization of stationary and moving beam radiation therapy techniques. , 1988, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[3]  T. Bortfeld,et al.  Methods of image reconstruction from projections applied to conformation radiotherapy. , 1990, Physics in medicine and biology.

[4]  B. Lind Properties of an algorithm for solving the inverse problem in radiation therapy , 1990 .

[5]  Barbara Kaltenbacher,et al.  On Broyden's method for the regularization of nonlinear ill-posed problems , 1998 .

[6]  Fernando Alonso,et al.  Intensity-modulated radiotherapy – a large scale multi-criteria programming problem , 2003, OR Spectr..

[7]  Ping Xia,et al.  A new smoothing procedure to reduce delivery segments for static MLC-based IMRT planning. , 2004, Medical physics.

[8]  R Mohan,et al.  The impact of fluctuations in intensity patterns on the number of monitor units and the quality and accuracy of intensity modulated radiotherapy. , 2000, Medical physics.

[9]  F Nüsslin,et al.  Intensity modulated photon beams subject to a minimal surface smoothing constraint. , 2000, Physics in medicine and biology.

[10]  S. Webb,et al.  Inverse planning with constraints to generate smoothed intensity-modulated beams. , 1998, Physics in medicine and biology.

[11]  Radhe Mohan,et al.  Incorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization. , 2002, Medical physics.

[12]  A. Ahnesjö,et al.  Dose calculations for external photon beams in radiotherapy. , 1999, Physics in medicine and biology.

[13]  J. Löf,et al.  Development of a general framework for optimization of radiation therapy , 2000 .

[14]  Daniela Calvetti,et al.  Regularization of inverse planning for intensity-modulated radiotherapy. , 2005, Medical physics.

[15]  J Yang,et al.  Smoothing intensity-modulated beam profiles to improve the efficiency of delivery. , 2001, Medical physics.

[16]  Benedick A Fraass,et al.  Improving IMRT delivery efficiency using intensity limits during inverse planning. , 2005, Medical physics.

[17]  William Rundell,et al.  Surveys on solution methods for inverse problems , 2000 .

[18]  S. Webb Optimizing the planning of intensity-modulated radiotherapy. , 1994, Physics in medicine and biology.

[19]  Lars Eldén,et al.  Partial least-squares vs. Lanczos bidiagonalization - I: analysis of a projection method for multiple regression , 2004, Comput. Stat. Data Anal..

[20]  S Webb,et al.  An optimization algorithm that incorporates IMRT delivery constraints. , 2002, Physics in medicine and biology.

[21]  P. Hansen Numerical tools for analysis and solution of Fredholm integral equations of the first kind , 1992 .

[22]  Johnathan M. Bardsley,et al.  A Nonnegatively Constrained Convex Programming Method for Image Reconstruction , 2003, SIAM J. Sci. Comput..

[23]  L. Nazareth A Relationship between the BFGS and Conjugate Gradient Algorithms and Its Implications for New Algorithms , 1979 .

[24]  Johnathan M Bardsley A limited-memory, quasi-Newton preconditioner for nonnegatively constrained image reconstruction. , 2004, Journal of the Optical Society of America. A, Optics, image science, and vision.

[25]  James G. Nagy,et al.  Preconditioned iterative regularization for Ill-posed problems , 1992 .

[26]  Anders Forsgren,et al.  Using eigenstructure of the Hessian to reduce the dimension of the intensity modulated radiation therapy optimization problem , 2006, Ann. Oper. Res..

[27]  Yair Censor,et al.  Inherent smoothness of intensity patterns for intensity modulated radiation therapy generated by simultaneous projection algorithms. , 2004, Physics in medicine and biology.

[28]  Alexei V Chvetsov L-curve analysis of radiotherapy optimization problems. , 2005, Medical physics.

[29]  Michael A. Saunders,et al.  User''s guide for NPSOL (Ver-sion 4.0): A FORTRAN package for nonlinear programming , 1984 .

[30]  M. Alber,et al.  Optimization of intensity modulated radiotherapy under constraints for static and dynamic MLC delivery. , 2001, Physics in medicine and biology.

[31]  M. Alber,et al.  On the degeneracy of the IMRT optimization problem. , 2002, Medical physics.

[32]  A. N. Tikhonov,et al.  REGULARIZATION OF INCORRECTLY POSED PROBLEMS , 1963 .

[33]  L. Xing,et al.  Iterative methods for inverse treatment planning. , 1996, Physics in medicine and biology.

[34]  Nzhde Agazaryan,et al.  Degeneracy, frequency response and filtering in IMRT optimization. , 2004, Physics in medicine and biology.