Chitosan-SiO2-multiwall carbon nanotubes nanocomposite: a novel matrix for the immobilization of creatine amidinohydrolase.

A matrix made up of chitosan-SiO(2)-multiwall carbon nanotubes (CHIT-SiO(2)-MWCNTs) nanocomposite was fabricated to investigate the immobilization of creatine amidinohydrolase (CAH). CAH enzyme was covalently immobilized with the CHIT-SiO(2)-MWCNTs matrix using glutaraldehyde as a linker. The resulting CAH/CHIT-SiO(2)-MWCNTs biomatrix was characterized with Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and cyclic voltammetry (CV) taking CHIT-SiO(2)-MWNTs as a reference. The influence of various parameters on CAH enzyme activity within the matrix was investigated including pH, temperature, and time. The Michaelis-Menten constant and apparent activities for the CAH enzyme were calculated to be 0.58 mM and 83.16 mg/cm(2), respectively; indicating CHIT-SiO(2)-MWCNTs nanocomposite matrix has a high affinity to immobilize CAH enzyme.

[1]  J. Mano,et al.  Chitosan derivatives bearing cyclodextrin cavitiesas novel adsorbent matrices , 2006 .

[2]  N. Tietz,et al.  Textbook of clinical chemistry , 1986 .

[3]  B. Danielsson,et al.  Determination of creatinine by an ammonia-sensitive semiconductor structure and immobilized enzymes. , 1986, Analytical chemistry.

[4]  João F Mano,et al.  Hydroxypropyl chitosan bearing beta-cyclodextrin cavities: synthesis and slow release of its inclusion complex with a model hydrophobic drug. , 2005, Macromolecular bioscience.

[5]  Zhong Lin Wang,et al.  Multiwall carbon nanotubes made of monochirality graphite shells. , 2006, Journal of the American Chemical Society.

[6]  A. Tiwari,et al.  Electrochemical detection of a breast cancer susceptible gene using cDNA immobilized chitosan-co-polyaniline electrode. , 2009, Talanta.

[7]  Keiichi Kaneto,et al.  An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film. , 2005, Biomaterials.

[8]  K. Yoda,et al.  Multi-enzyme membrane electrodes for determination of creatinine and creatine in serum. , 1983, Clinical chemistry.

[9]  G. Böhm,et al.  Stabilization of creatinase from Pseudomonas putida by random mutagenesis , 1993, Protein science : a publication of the Protein Society.

[10]  W. Wernet,et al.  A polypyrrole/three-enzyme electrode for creatinine detection , 1995 .

[11]  Rui L. Reis,et al.  Carboxymethyl chitosan-graft-phosphatidylethanolamine: Amphiphilic matrices for controlled drug delivery , 2007 .

[12]  S. Dhakate,et al.  Synthesis of electrically active biopolymer–SiO2 nanocomposite aerogel , 2007 .

[13]  M. Prabaharan Review Paper: Chitosan Derivatives as Promising Materials for Controlled Drug Delivery , 2008, Journal of biomaterials applications.

[14]  R. Mccomb,et al.  Effect of high creatine content on the Kodak single-slide method for creatinine. , 1988, Clinical chemistry.

[15]  I. Bahar,et al.  A stable three enzyme creatinine biosensor. 2. Analysis of the impact of silver ions on creatine amidinohydrolase. , 2005, Acta biomaterialia.

[16]  I. Karube,et al.  Amperometric determination of creatinine with a biosensor based on immobilized creatininase and nitrifying bacteria , 1983 .

[17]  Robert Koncki,et al.  Bienzymatic potentiometric electrodes for creatine and l-arginine determination , 1996 .

[18]  A. Tiwari,et al.  Electrochemical Synthesis of Chitosan-co-polyaniline/WO3⋅nH2O Composite Electrode for Amperometric Detection of NO2 Gas , 2008 .

[19]  N. Mohammadi,et al.  The contact angle of thin-uncured epoxy films: thickness effect , 2004 .

[20]  A. Tiwari,et al.  Electrochemical Study of Chitosan‐SiO2‐MWNT Composite Electrodes for the Fabrication of Cholesterol Biosensors , 2008 .

[21]  Xiaoyong Zou,et al.  A novel glucose biosensor based on immobilization of glucose oxidase in chitosan on a glassy carbon electrode modified with gold-platinum alloy nanoparticles/multiwall carbon nanotubes. , 2007, Analytical biochemistry.

[22]  J. Irudayaraj,et al.  Examination of Cholesterol oxidase attachment to magnetic nanoparticles , 2005, Journal of nanobiotechnology.

[23]  Robert Koncki,et al.  Recent developments in potentiometric biosensors for biomedical analysis. , 2007, Analytica chimica acta.