Sentinel-3A/B SLSTR Pre-Launch Calibration of the Thermal InfraRed Channels

The first two models of the Sea and Land Surface Temperature Radiometers (SLSTR) for the European Copernicus Sentinel-3 missions were tested prior to launch at the Rutherford Appleton Laboratory space instrument calibration facility. The pre-launch tests provide an essential reference that ensures that the flight data of SLSTR are calibrated to the same standards needed for surface temperature measurements and to those used by shipborne radiometers for Fiducial Reference Measurement (FRM). The radiometric calibrations of the thermal infrared channels were validated against accurate and traceable reference BB sources under flight representative thermal vacuum environment. Measurements were performed in both earth views for source temperatures covering the main operating range, for different instrument configurations and for the full field-of-view of the instruments. The data were used to derive non-linearity curves to be used in the level-1 processing. All results showed that the measured brightness temperatures and radiometric noise agreed within the requirements for the mission. An inconsistency that particularly affected SLSTR-A was observed which has been attributed to an internal stray light error. A correction for the stray light has been proposed to reduce the error. The internal stray light error was reduced for SLSTR-B by replacing the coating on the main aperture stop. We present a description of the test methodology and the key results.

[1]  C. Donlon,et al.  The Global Monitoring for Environment and Security (GMES) Sentinel-3 mission , 2012 .

[2]  John J. Remedios,et al.  The Advanced Along Track Scanning Radiometer (AATSR) and its predecessors ATSR-1 and ATSR-2: An introduction to the special issue , 2012 .

[3]  Dave Smith,et al.  ATSR infrared radiometric calibration and in-orbit performance , 2012 .

[4]  Kevin Middleton,et al.  Calibration approach and plan for the sea and land surface temperature radiometer , 2014 .

[5]  I. Mason,et al.  Blackbody calibration sources of high accuracy for a spaceborne infrared instrument: the Along Track Scanning Radiometer. , 1996, Applied optics.

[6]  Karim Djotni,et al.  Cooled infrared filters and dichroics for the sea and land surface temperature radiometer. , 2013, Applied optics.

[7]  A. Prokhorov,et al.  Application of the three-component bidirectional reflectance distribution function model to Monte Carlo calculation of spectral effective emissivities of nonisothermal blackbody cavities. , 2012, Applied optics.

[8]  C. Vidal,et al.  Guide to the expression of uncertainty , 2019, Springer Reference Medizin.

[9]  C. Monte,et al.  High-Accuracy Emissivity Data on the Coatings Nextel 811-21, Herberts 1534, Aeroglaze Z306 and Acktar Fractal Black , 2017 .

[10]  E Theocharous,et al.  CEOS comparison of IR brightness temperature measurements in support of satellite validation. Part II: Laboratory comparison of the brightness temperature of blackbodies. , 2010 .

[11]  Bruce A. Wielicki,et al.  Satellite Instrument Calibration for Measuring Global Climate Change: Report of a Workshop , 2004 .

[12]  J. Frerick,et al.  SLSTR: a high accuracy dual scan temperature radiometer for sea and land surface monitoring from space , 2010 .

[13]  Jonathan P. D. Mittaz,et al.  Comparison of the Sentinel-3A and B SLSTR Tandem Phase Data Using Metrological Principles , 2020, Remote. Sens..

[14]  A. M. Zavody,et al.  A radiative transfer model for sea surface temperature retrieval for the along‐track scanning radiometer , 1995 .

[15]  N. Fox,et al.  Absolute linearity measurements on HgCdTe detectors in the infrared region. , 2004, Applied optics.

[16]  Jens Nieke,et al.  Sea and Land Surface Temperature Radiometer detection assembly design and performance , 2014 .

[17]  Xu Liu,et al.  Spectrally Dependent CLARREO Infrared Spectrometer Calibration Requirement for Climate Change Detection. , 2017, Journal of climate.