A parametric study of the energy performance of double-skin façades in climatic conditions of Crete, Greece

Double-skin facades (DSF) are considered an innovative energy efficient technique that gained an increasing interest worldwide. The aim of this article is to perform a parametric study for the DSFs’ configuration in hot climatic conditions. The parameters under investigation are the ventilation rate, the shading requirements and the cavity dimensions. A newly erected building with surface area of 18 500 m2 is considered as the basis for the parametric study. The building is monitored and simulated using Energy Plus. The parametric analysis showed that the ventilation rate in the DSFs’ configuration is of a major importance especially during the cooling season. The lack of adequate ventilation increases the cooling demands and deteriorates the DSF's effectiveness. Finally, the integration of shading in the overall construction, especially the external ones, results to 24% annual energy conservation.

[1]  André De Herde,et al.  Optimal operation of a south double-skin facade , 2004 .

[2]  Argiris Tzikopoulos,et al.  Modeling energy efficiency of bioclimatic buildings , 2005 .

[3]  A. Athienitis,et al.  The impact of shading design and control on building cooling and lighting demand , 2007 .

[4]  Herricos Stapountzis,et al.  Flow and heat transfer inside a PV/T collector for building application , 2012 .

[5]  C. Ghiaus,et al.  Potential for free-cooling by ventilation , 2006 .

[6]  André De Herde,et al.  Natural cooling strategies efficiency in an office building with a double-skin facade , 2004 .

[7]  K. F. Fong,et al.  Investigation on energy performance of double skin façade in Hong Kong , 2009 .

[8]  E. Gratia,et al.  Guidelines for improving natural daytime ventilation in an office building with a double-skin facade , 2007 .

[9]  Armando C. Oliveira,et al.  Effect of louver shading devices on building energy requirements , 2010 .

[10]  Marjan Sarshar,et al.  Thermal behaviour of a ventilated double skin façade in hot arid climate , 2010 .

[11]  Richard Heimrath,et al.  On the Typology, Costs, Energy Performance, Environmental Quality and Operational Characteristics of Double Skin Façades in European Buildings , 2007 .

[12]  W. Fisk,et al.  Summary of human responses to ventilation. , 2004, Indoor air.

[13]  André De Herde,et al.  The most efficient position of shading devices in a double-skin facade , 2007 .

[14]  Giorgio Baldinelli,et al.  Double skin facades for warm climate regions : Analysis of a solution with an integrated movable shading system , 2009 .

[15]  L. Cabeza,et al.  Green vertical systems for buildings as passive systems for energy savings , 2011 .

[16]  K. Pavlou,et al.  On the efficiency of night ventilation techniques applied to residential buildings , 2010 .

[17]  N. Hamza Double versus single skin facades in hot arid areas , 2008 .

[18]  Deuk-Woo Kim,et al.  Difficulties and limitations in performance simulation of a double skin faade with EnergyPlus , 2011 .

[19]  Richard Heimrath,et al.  State of the Art of Double Skin Facades in Europe, The results of WP1 of the BESTFAÇADE Project , 2006 .

[20]  Hussain H. Alzoubi,et al.  Assessment of building façade performance in terms of daylighting and the associated energy consumption in architectural spaces: Vertical and horizontal shading devices for southern exposure facades , 2010 .