Cardiac and respiratory double self‐gated cine MRI in the mouse at 7 T

ECG‐gated cardiac MRI in the mouse is hindered by many technical difficulties in ECG signal recording inside static and variable high magnetic scanner fields. The present study proposes an alternative robust method of acquiring auto‐gated cardiac and respiratory cine images in mouse heart. In our approach, a motion synchronization signal is extracted from the echo peak MR signal of a non‐triggered radial acquisition. This signal is then used for both cardiac and respiratory retrospective gating before cine image reconstruction. Highly asymmetric echoes were acquired to achieve the radial k‐space sampling in order to avoid radial acquisition related artifacts and to increase auto‐gating robustness. In vivo experiments demonstrated the feasibility and robustness of self‐gated cine‐MRI in the mouse heart at 7T. The signal‐to‐noise and contrast‐to‐noise ratios of the self‐gated and ECG‐gated images were comparable, all parameters being equal. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.

[1]  A Haase,et al.  Developmental changes of cardiac function and mass assessed with MRI in neonatal, juvenile, and adult mice. , 2000, American journal of physiology. Heart and circulatory physiology.

[2]  J. Felblinger,et al.  Suppression of MR gradient artefacts on electrophysiological signals based on an adaptive real-time filter with LMS coefficient updates , 2004, Magnetic Resonance Materials in Physics, Biology and Medicine.

[3]  W. Härdle Applied Nonparametric Regression , 1992 .

[4]  D. Peters,et al.  Undersampled projection reconstruction applied to MR angiography , 2000, Magnetic resonance in medicine.

[5]  G W Lenz,et al.  Electrocardiograph‐independent, “wireless” cardiovascular cine MR imaging , 1991, Journal of magnetic resonance imaging : JMRI.

[6]  Andrew C Larson,et al.  Self‐gated cardiac cine MRI , 2004, Magnetic resonance in medicine.

[7]  T A Spraggins,et al.  Wireless retrospective gating: application to cine cardiac imaging. , 1990, Magnetic resonance imaging.

[8]  B K Rutt,et al.  Effects of polar sampling in k‐space , 1996, Magnetic resonance in medicine.

[9]  Y. Geoffrion,et al.  A simple fiber optic monitor of cardiac and respiratory activity for biomedical magnetic resonance applications , 1986, Magnetic resonance in medicine.

[10]  Kieran Clarke,et al.  Fast, high‐resolution in vivo cine magnetic resonance imaging in normal and failing mouse hearts on a vertical 11.7 T system , 2003, Journal of magnetic resonance imaging : JMRI.

[11]  R. Mark Henkelman,et al.  In vivo multiple‐mouse MRI at 7 Tesla , 2005, Magnetic resonance in medicine.

[12]  Anja C S Brau,et al.  Cine magnetic resonance microscopy of the rat heart using cardiorespiratory‐synchronous projection reconstruction , 2004, Journal of magnetic resonance imaging : JMRI.

[13]  Stefan Neubauer,et al.  Magnetic resonance microimaging for noninvasive quantification of myocardial function and mass in the mouse , 1998, Magnetic resonance in medicine.

[14]  R. Frayne,et al.  Minimizing interference from magnetic resonance imagers during electrocardiography , 1998, IEEE Transactions on Biomedical Engineering.

[15]  Stefan Neubauer,et al.  High‐resolution MRI with cardiac and respiratory gating allows for accurate in vivo atherosclerotic plaque visualization in the murine aortic arch , 2003, Magnetic resonance in medicine.

[16]  Jan Timmer,et al.  The gridding method for image reconstruction by Fourier transformation , 1995, IEEE Trans. Medical Imaging.

[17]  A T Barker,et al.  The effect of rapid rise-time magnetic fields on the ECG of the rat. , 1982, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[18]  Kai Hu,et al.  Cardiac magnetic resonance imaging in small animal models of human heart failure , 2003, Medical Image Anal..

[19]  A Haase,et al.  Magnetic resonance imaging of coronary arteries and heart valves in a living mouse: techniques and preliminary results. , 2000, Journal of magnetic resonance.

[20]  R A Wind,et al.  A compact respiratory‐triggering device for routine microimaging of laboratory mice , 1998, Journal of magnetic resonance imaging : JMRI.

[21]  Volker Rasche,et al.  Resampling of data between arbitrary grids using convolution interpolation , 1999, IEEE Transactions on Medical Imaging.

[22]  J P Ridgway,et al.  A system for cardiac and respiratory gating of a magnetic resonance imager. , 1989, Clinical physics and physiological measurement : an official journal of the Hospital Physicists' Association, Deutsche Gesellschaft fur Medizinische Physik and the European Federation of Organisations for Medical Physics.

[23]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[24]  Dana C Peters,et al.  Centering the projection reconstruction trajectory: Reducing gradient delay errors , 2003, Magnetic resonance in medicine.