Calibration of the scales of areal surface topography-measuring instruments: part 1. Measurement noise and residual flatness

In this paper, we present methods for determining the measurement noise and residual flatness of areal surface topography-measuring instruments. The methods are compliant with draft international specification standards on areal surface texture. We first introduce the international standards framework and then present current methods based on averaging and subtraction to isolate the measurement noise and residual flatness from the sample surface topography. These methods are relatively difficult to apply and time consuming in practice. An alternative method is presented based on thresholding and filtering techniques. This method is simple to apply in practice. Traceability and measurement uncertainty are discussed.

[1]  Claudiu L Giusca,et al.  Calibration of the scales of areal surface topography measuring instruments: part 3. Resolution , 2013 .

[2]  Richard K. Leach,et al.  TOPICAL REVIEW: Bandwidth characteristics and comparisons of surface texture measuring instruments , 2010 .

[3]  K. J. Stout,et al.  Three-Dimensional Surface Topography , 2000 .

[4]  R. Steiner History and progress on accurate measurements of the Planck constant , 2013, Reports on progress in physics. Physical Society.

[5]  H Han Haitjema,et al.  Noise bias removal in profile measurements , 2005 .

[6]  J C Wyant,et al.  Absolute measurement of surface roughness. , 1990, Applied optics.

[7]  Claudiu L Giusca,et al.  A virtual machine-based uncertainty evaluation for a traceable areal surface texture measuring instrument , 2011 .

[8]  R. K. Leach,et al.  Determination of the point spread function of a coherence scanning interferometer. , 2011 .

[9]  Claudiu L Giusca,et al.  Development and characterization of a new instrument for the traceable measurement of areal surface texture , 2009 .

[10]  David J. Whitehouse,et al.  Some theoretical aspects of error separation techniques in surface metrology , 1976 .

[11]  Paul J. Scott,et al.  Fast algorithm of the Robust Gaussian Regression Filter for Areal Surface Analysis , 2010 .

[12]  K. J. Stout,et al.  Calibration of translational tables for use in three-dimensional surface topography measurement systems , 1994 .

[13]  Kazuhisa Yanagi,et al.  An outlier correction procedure and its application to areal surface data measured by optical instruments , 2010 .

[14]  R. Leach Optical measurement of surface topography , 2011 .