Optimization of MR Fingerprinting for Free-Breathing Quantitative Abdominal Imaging

In this work, we propose a free-breathing magnetic resonance fingerprinting method that can be used to obtain $B_1^+$-robust quantitative maps of the abdomen in a clinically acceptable time. A three-dimensional MR fingerprinting sequence with a radial stack-of-stars trajectory was implemented for quantitative abdominal imaging. The k-space acquisition ordering was adjusted to improve motion-robustness. The flip angle pattern was optimized using the Cramer-Rao Lower Bound, and the encoding efficiency of sequences with 300, 600, 900, and 1800 flip angles was evaluated. To validate the sequence, a movable multicompartment phantom was developed. Reference multiparametric maps were acquired under stationary conditions using a previously validated MRF method. Periodic motion of the phantom was used to investigate the motion-robustness of the proposed sequence. The best performing sequence length (600 flip angles) was used to image the abdomen during a free-breathing volunteer scan. When using a series of 600 or more flip angles, the estimated $T_1$ values in the stationary phantom showed good agreement with the reference scan. Phantom experiments revealed that motion-related artefacts can appear in the quantitative maps, and confirmed that a motion-robust k-space ordering is essential in preventing these artefacts. The in vivo scan demonstrated that the proposed sequence can produce clean parameter maps while the subject breathes freely. Using this sequence, it is possible to generate $B_1^+$-robust quantitative maps of proton density, $T_1$, and $B_1^+$ under free-breathing conditions at a clinically usable resolution within 5 minutes.

[1]  Sean C L Deoni,et al.  Quantitative Relaxometry of the Brain , 2010, Topics in magnetic resonance imaging : TMRI.

[2]  G. Gerig,et al.  Rapid Radial T1 and T2 Mapping of the Hip Articular Cartilage With Magnetic Resonance Fingerprinting , 2019, Journal of magnetic resonance imaging : JMRI.

[3]  Moritz Diehl,et al.  CasADi: a software framework for nonlinear optimization and optimal control , 2018, Mathematical Programming Computation.

[4]  Wilson Fong Handbook of MRI Pulse Sequences , 2005 .

[5]  René M. Botnar,et al.  Rigid motion‐corrected magnetic resonance fingerprinting , 2018, Magnetic resonance in medicine.

[6]  D. Sodickson,et al.  Optimized quantification of spin relaxation times in the hybrid state , 2017, Magnetic resonance in medicine.

[7]  Dan Ma,et al.  Image reconstruction algorithm for motion insensitive MR Fingerprinting (MRF): MORF , 2018, Magnetic resonance in medicine.

[8]  J. Duerk,et al.  Magnetic Resonance Fingerprinting , 2013, Nature.

[9]  D. Look,et al.  Time Saving in Measurement of NMR and EPR Relaxation Times , 1970 .

[10]  M. Beach,et al.  Changing the paradigm for diagnostic MRI in pediatrics: Don't hold your breath , 2017, Paediatric anaesthesia.

[11]  W. W. Hansen,et al.  Nuclear Induction , 2011 .

[12]  Wilburta Q. Lindh Delmar's Comprehensive Medical Assisting: Administrative and Clinical Competencies , 1997 .

[13]  P. Roemer,et al.  The NMR phased array , 1990, Magnetic resonance in medicine.

[14]  Christopher G. Roth,et al.  Optimizing abdominal MR imaging: approaches to common problems. , 2010, Radiographics : a review publication of the Radiological Society of North America, Inc.

[15]  Daniel K. Sodickson,et al.  Towards Routine Clinical Use of Radial Stack-of-Stars 3D Gradient-Echo Sequences for Reducing Motion Sensitivity , 2014 .

[16]  Paul Strauss,et al.  Magnetic Resonance Imaging Physical Principles And Sequence Design , 2016 .

[17]  B. Rutt,et al.  Rapid combined T1 and T2 mapping using gradient recalled acquisition in the steady state , 2003, Magnetic resonance in medicine.

[18]  F. Knoll,et al.  Multiparametric imaging with heterogeneous radiofrequency fields , 2016, Nature Communications.

[19]  Jeffrey A. Fessler,et al.  Nonuniform fast Fourier transforms using min-max interpolation , 2003, IEEE Trans. Signal Process..

[20]  R. Turner,et al.  Optimization of 3-D MP-RAGE Sequences for Structural Brain Imaging , 2000, NeuroImage.

[21]  Barak A. Pearlmutter,et al.  Automatic differentiation in machine learning: a survey , 2015, J. Mach. Learn. Res..

[22]  Rachel W Chan,et al.  The influence of radial undersampling schemes on compressed sensing reconstruction in breast MRI , 2012, Magnetic resonance in medicine.

[23]  Shaihan J Malik,et al.  Joint system relaxometry (JSR) and Crámer‐Rao lower bound optimization of sequence parameters: A framework for enhanced precision of DESPOT T1 and T2 estimation , 2018, Magnetic resonance in medicine.

[24]  Yun Jiang,et al.  SVD Compression for Magnetic Resonance Fingerprinting in the Time Domain , 2014, IEEE Transactions on Medical Imaging.

[25]  Yong Chen,et al.  MR Fingerprinting for Rapid Quantitative Abdominal Imaging. , 2016, Radiology.

[26]  Daniel K Sodickson,et al.  Exploring the sensitivity of magnetic resonance fingerprinting to motion. , 2018, Magnetic resonance imaging.

[27]  Qianjin Feng,et al.  Rigid motion correction for magnetic resonance fingerprinting with sliding-window reconstruction and image registration. , 2019, Magnetic resonance imaging.

[28]  Michael B. Smith,et al.  Central brightening due to constructive interference with, without, and despite dielectric resonance , 2005, Journal of magnetic resonance imaging : JMRI.

[29]  M. Griswold,et al.  MR fingerprinting using fast imaging with steady state precession (FISP) with spiral readout , 2015, Magnetic resonance in medicine.

[30]  F. Knoll,et al.  Low rank alternating direction method of multipliers reconstruction for MR fingerprinting , 2016, Magnetic resonance in medicine.

[31]  Michela Tosetti,et al.  Spiral MR fingerprinting at 7T with simultaneous B1 estimation. , 2017, Magnetic resonance imaging.

[32]  R. Ordidge,et al.  Frequency offset corrected inversion (FOCI) pulses for use in localized spectroscopy , 1996, Magnetic resonance in medicine.

[33]  S. Kay Fundamentals of statistical signal processing: estimation theory , 1993 .

[34]  Justin P. Haldar,et al.  Optimal Experiment Design for Magnetic Resonance Fingerprinting: Cramér-Rao Bound Meets Spin Dynamics , 2017, IEEE Transactions on Medical Imaging.

[35]  Lawrence L. Wald,et al.  3D MR fingerprinting with accelerated stack-of-spirals and hybrid sliding-window and GRAPPA reconstruction , 2017, NeuroImage.

[36]  Nikola Stikov,et al.  Practical medical applications of quantitative MR relaxometry , 2012, Journal of magnetic resonance imaging : JMRI.

[37]  Brian M Dale,et al.  Abdominal MRI at 3.0 T: the basics revisited. , 2006, AJR. American journal of roentgenology.

[38]  J Hennig,et al.  Reduced circular field‐of‐view imaging , 1998, Magnetic resonance in medicine.

[39]  Brian A Hargreaves,et al.  Flexible and efficient optimization of quantitative sequences using automatic differentiation of Bloch simulations , 2019, Magnetic resonance in medicine.

[40]  A. Huber,et al.  Liver MR relaxometry at 3T – segmental normal T1 and T2* values in patients without focal or diffuse liver disease and in patients with increased liver fat and elevated liver stiffness , 2019, Scientific Reports.

[41]  Olaf Dössel,et al.  An Optimal Radial Profile Order Based on the Golden Ratio for Time-Resolved MRI , 2007, IEEE Transactions on Medical Imaging.