Superiority of Ambulatory Over Clinic Blood Pressure Measurement in Predicting Mortality: The Dublin Outcome Study

The purpose of this study was to determine if ambulatory blood pressure measurement predicted total and cardiovascular mortality over and beyond clinic blood pressure measurement and other cardiovascular risk factors; 5292 untreated hypertensive patients referred to a single blood pressure clinic who had clinic and ambulatory blood pressure measurement at baseline were followed up in a prospective study of mortality outcome. Multiple Cox regression was used to model time to total and cause-specific mortality for ambulatory blood pressure measurement while adjusting for clinic blood pressure measurement and other risk factors at baseline. There were 646 deaths (of which 389 were cardiovascular) during a median follow-up period of 8.4 years. With adjustment for gender, age, risk indices, and clinic blood pressure, higher mean values of ambulatory blood pressure were independent predictors for cardiovascular mortality. The relative hazard ratio for each 10-mm Hg increase in systolic blood pressure was 1.12 (1.06 to 1.18; P<0.001) for daytime and 1.21 (1.15 to 1.27; P<0.001) for nighttime systolic blood pressure. The hazard ratios for each 5-mm Hg increase in diastolic blood pressure were 1.02 (0.99 to 1.07; P=NS) for daytime and 1.09 (1.04 to 1.13; P<0.01) for nighttime diastolic pressures. The hazard ratios for nighttime ambulatory blood pressure remained significant after adjustment for daytime ambulatory blood pressure. These results have 2 important clinical messages: ambulatory measurement of blood pressure is superior to clinic measurement in predicting cardiovascular mortality, and nighttime blood pressure is the most potent predictor of outcome.

[1]  T. Ohkubo,et al.  Prediction of mortality by ambulatory blood pressure monitoring versus screening blood pressure measurements: a pilot study in Ohasama , 1997, Journal of hypertension.

[2]  A. Stanton,et al.  Ambulatory blood pressure measurement as a predictor of outcome in an Irish population: methodology for ascertaining mortality outcome , 2003, Blood pressure monitoring.

[3]  R. Collins,et al.  Blood pressure, stroke, and coronary heart disease Part 1, prolonged differences in blood pressure: prospective observational studies corrected for the regression dilution bias , 1990, The Lancet.

[4]  M. Sokolow,et al.  The prognostic value of ambulatory blood pressures. , 1983, JAMA.

[5]  Eoin O'Brien,et al.  ABC of Hypertension , 1981 .

[6]  Yutaka Imai,et al.  European Society of Hypertension recommendations for conventional, ambulatory and home blood pressure measurement , 2003, Journal of hypertension.

[7]  F. Mee,et al.  Accuracy of the SpaceLabs 90207 determined by the British Hypertension Society protocol. , 1991, Journal of hypertension.

[8]  YasumasaYamamoto,et al.  Adverse Effect of Nighttime Blood Pressure on the Outcome of Lacunar Infarct Patients , 1998 .

[9]  G. Schillaci,et al.  Blunted nocturnal fall in blood pressure in hypertensive women with future cardiovascular morbid events. , 1993, Circulation.

[10]  E. O’Brien,et al.  Can improved software facilitate the wider use of ambulatory blood pressure measurement in clinical practice? , 2004, Blood pressure monitoring.

[11]  S. Pede,et al.  Ambulatory pulse pressure: a potent predictor of total cardiovascular risk in hypertension. , 1998, Hypertension.

[12]  E. O’Brien,et al.  Night-time blood pressure: dipping into the future? , 2002, Journal of hypertension.

[13]  J. Laragh,et al.  How common is white coat hypertension? , 1988, JAMA.

[14]  R. Senior,et al.  Cardiovascular outcome in white-coat versus sustained mild hypertension: a 10-year follow-up study. , 1998, Circulation.

[15]  G. Reboldi,et al.  Ambulatory blood pressure. An independent predictor of prognosis in essential hypertension. , 1994, Hypertension.

[16]  J E Schwartz,et al.  Stroke Prognosis and Abnormal Nocturnal Blood Pressure Falls in Older Hypertensives , 2001, Hypertension.

[17]  L. Ruilope,et al.  Prognostic value of ambulatory blood pressure monitoring in refractory hypertension: a prospective study. , 1998, Hypertension.

[18]  Gianfranco Parati,et al.  Predicting cardiovascular risk using conventional vs ambulatory blood pressure in older patients with systolic hypertension. , 1999 .

[19]  J. Kimura,et al.  Adverse effect of nighttime blood pressure on the outcome of lacunar infarct patients. , 1998, Stroke.

[20]  M. Kikuya,et al.  Prediction of stroke by ambulatory blood pressure monitoring versus screening blood pressure measurements in a general population: the Ohasama study , 2000, Journal of hypertension.

[21]  F. Magrini,et al.  Cardiovascular target organ damage in essential hypertensives with or without reproducible nocturnal fall in blood pressure , 2004, Journal of hypertension.

[22]  F. Mee,et al.  Evaluation of three devices for self-measurement of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332, and Nissei DS-175. , 1996, Blood pressure monitoring.

[23]  N. Atkins,et al.  Diagnosis of white coat hypertension by ambulatory blood pressure monitoring. , 1999, Hypertension.

[24]  Peter W de Leeuw,et al.  Prognostic value of ambulatory blood-pressure recordings in patients with treated hypertension. , 2003, The New England journal of medicine.

[25]  R. Collins,et al.  Age-specific relevance of usual blood pressure to vascular mortality: a meta-analysis of individual data for one million adults in 61 prospective studies , 2002, The Lancet.

[26]  M. Kikuya,et al.  Prognostic significance of the nocturnal decline in blood pressure in individuals with and without high 24-h blood pressure: the Ohasama study , 2002, Journal of hypertension.

[27]  E. O’Brien,et al.  DIPPERS AND NON-DIPPERS , 1988, The Lancet.