Optimization and performance evaluation of a conical mirror based fluorescence molecular tomography imaging system

We performed numerical simulations and phantom experiments with a conical mirror based fluorescence molecular tomography (FMT) imaging system to optimize its performance. With phantom experiments, we have compared three measurement modes in FMT: the whole surface measurement mode, the transmission mode, and the reflection mode. Our results indicated that the whole surface measurement mode performed the best. Then, we applied two different neutral density (ND) filters to improve the measurement's dynamic range. The benefits from ND filters are not as much as predicted. Finally, with numerical simulations, we have compared two laser excitation patterns: line and point. With the same excitation position number, we found that the line laser excitation had slightly better FMT reconstruction results than the point laser excitation. In the future, we will implement Monte Carlo ray tracing simulations to calculate multiple reflection photons, and create a look-up table accordingly for calibration.

[1]  Yue Zhao,et al.  Comparison of Regularization Methods in Fluorescence Molecular Tomography , 2014 .

[2]  Changqing Li,et al.  Nonconvex regularizations in fluorescence molecular tomography for sparsity enhancement , 2014, Physics in medicine and biology.

[3]  Jin He,et al.  Noncontact full-angle fluorescence molecular tomography system based on rotary mirrors. , 2015, Applied optics.

[4]  H Jiang,et al.  Quantitative optical image reconstruction of turbid media by use of direct-current measurements. , 2000, Applied optics.

[5]  Reheman Baikejiang,et al.  3D mouse shape reconstruction based on phase-shifting algorithm for fluorescence molecular tomography imaging system. , 2015, Applied optics.

[6]  Joyita Dutta,et al.  Illumination pattern optimization for fluorescence tomography: theory and simulation studies , 2010, Physics in medicine and biology.

[7]  Jie Tian,et al.  A fast reconstruction algorithm for fluorescence molecular tomography with sparsity regularization. , 2010, Optics express.

[8]  R. Leahy,et al.  A three-dimensional multispectral fluorescence optical tomography imaging system for small animals based on a conical mirror design. , 2009, Optics express.

[9]  Dianwen Zhu,et al.  Accelerated image reconstruction in fluorescence molecular tomography using a nonuniform updating scheme with momentum and ordered subsets methods , 2016, Journal of biomedical optics.

[10]  Andreas H. Hielscher,et al.  Non-contact small animal fluorescence imaging system for simultaneous multi-directional angular-dependent data acquisition. , 2014, Biomedical optics express.

[11]  Vasilis Ntziachristos,et al.  Experimental fluorescence tomography of tissues with noncontact measurements , 2004, IEEE Transactions on Medical Imaging.

[12]  Jianwen Luo,et al.  Fluorescence molecular tomography reconstruction via discrete cosine transform-based regularization , 2015, Journal of biomedical optics.

[13]  V. Ntziachristos Fluorescence molecular imaging. , 2006, Annual review of biomedical engineering.

[14]  Changqing Li,et al.  Nonuniform update for sparse target recovery in fluorescence molecular tomography accelerated by ordered subsets. , 2014, Biomedical optics express.

[15]  Wolfgang Bangerth,et al.  Non-contact fluorescence optical tomography with scanning patterned illumination. , 2006, Optics express.