Contextually-aware Fetal Sensing in Transabdominal Fetal Pulse Oximetry

Transabdominal fetal pulse oximetry (TFO) is a noninvasive technique that can provide physicians with a convenient measure of fetal oxygen saturation. This is accomplished by sending a known light intensity signal towards the mother’s abdomen, where it is modified by the maternal and fetal tissues, and observed some distance away. The measured signal, captured by a photodetector, contains a mixture of both maternal and fetal information, where the fetal portion must be extracted to calculate the fetal oxygen saturation. However, the ability to decouple the maternal and fetal components is highly dependent on the physiological and structural parameters of the physical system, making it difficult to robustly extract the fetal signal across patients over a long-period of time. In this work, we propose a contextually-aware sensing approach that utilizes additional information about the physical system (physiological, spatial, and temporal) to extract the fetal signal. It does this by using easily-measurable parameters of the mother’s physiology to reduce the maternal impact, incorporating data fusion techniques to combine spatial information from multiple detectors, and utilizing historical data points to improve and validate the fetal signal estimates. The efficacy of the proposed approach is supported by experimental evaluation using in vivo measurements captured on pregnant sheep.

[1]  A. Loundou,et al.  Intra- and interobserver agreement among obstetric experts in court regarding the review of abnormal fetal heart rate tracings and obstetrical management. , 2015, American journal of obstetrics and gynecology.

[2]  Ben Moore,et al.  APPROPRIATE TECHNOLOGY FOR BIRTH , 1985, The Lancet.

[3]  Sebastian Ley,et al.  Phantom materials mimicking the optical properties in the near infrared range for non-invasive fetal pulse oximetry , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  J M Rubin,et al.  Fetal depth and ultrasound path lengths through overlying tissues. , 1989, Ultrasound in medicine & biology.

[5]  S. Arridge,et al.  Estimation of optical pathlength through tissue from direct time of flight measurement , 1988 .

[6]  Z. Alfirevic,et al.  Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour. , 2006, The Cochrane database of systematic reviews.

[7]  Takashi Kusaka,et al.  Developmental Changes of Optical Properties in Neonates Determined by Near-Infrared Time-Resolved Spectroscopy , 2005, Pediatric Research.

[8]  J M Dambrosia,et al.  Uncertain value of electronic fetal monitoring in predicting cerebral palsy. , 1996, The New England journal of medicine.

[9]  Soheil Ghiasi,et al.  Optode Design Space Exploration for Clinically-robust Non-invasive Fetal Oximetry , 2019, ACM Trans. Embed. Comput. Syst..

[10]  A. Boulesteix,et al.  What is the “normal” fetal heart rate? , 2013, PeerJ.

[11]  Walter Karlen,et al.  Multiparameter Respiratory Rate Estimation From the Photoplethysmogram , 2013, IEEE Transactions on Biomedical Engineering.

[12]  Peter Husar,et al.  Simulation of Photon Propagation in Multi-layered Tissue for Non-invasive Fetal Pulse Oximetry , 2014 .

[13]  M. Kohl,et al.  Near-infrared optical properties of ex vivo human skin and subcutaneous tissues measured using the Monte Carlo inversion technique. , 1998, Physics in medicine and biology.

[14]  Gan Kok Beng,et al.  Applicability of adaptive noise cancellation to fetal heart rate detection using photoplethysmography , 2008, Comput. Biol. Medicine.

[15]  Peter Husar,et al.  Signal Separation for Transabdominal Non-invasive Fetal Pulse Oximetry using Comb Filters , 2018, 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[16]  N Ramanujam,et al.  Photon migration through fetal head in utero using continuous wave, near-infrared spectroscopy: development and evaluation of experimental and numerical models. , 2000, Journal of biomedical optics.

[17]  W. Zijlstra,et al.  Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin. , 1991, Clinical chemistry.

[18]  K. Hökegård,et al.  Cesarean section and intraoperative surgical complications. , 1984, Acta obstetricia et gynecologica Scandinavica.

[19]  Stuart R Lipsitz,et al.  Relationship Between Cesarean Delivery Rate and Maternal and Neonatal Mortality. , 2015, JAMA.

[20]  David A Boas,et al.  Monte Carlo simulation of photon migration in 3D turbid media accelerated by graphics processing units. , 2009, Optics express.

[21]  Appropriate technology for birth , 1985, The Lancet.

[22]  N. Uldbjerg,et al.  Risk of respiratory morbidity in term infants delivered by elective caesarean section: cohort study , 2007, BMJ : British Medical Journal.

[23]  Suzanne Wendelken,et al.  Noninvasive Detection of the Hemodynamic Stress of Exercise Using the Photoplethysmogram , 2008, Journal of Clinical Monitoring and Computing.

[24]  M. Goldacre,et al.  Caesarean section is associated with an increased risk of childhood-onset type 1 diabetes mellitus: a meta-analysis of observational studies , 2008, Diabetologia.

[25]  Peter Husar,et al.  Extraction of the Fetal Pulse Curve for Transabdominal Pulse Oximetry using Adaptive and Comb Filters* , 2019, 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[26]  E. Chan,et al.  Pulse oximetry: understanding its basic principles facilitates appreciation of its limitations. , 2013, Respiratory medicine.

[27]  D. Boas,et al.  Trans-abdominal monitoring of fetal arterial blood oxygenation using pulse oximetry. , 2000, Journal of biomedical optics.

[28]  S. Fieni,et al.  Amniotic fluid dynamics. , 2004, Acta bio-medica : Atenei Parmensis.

[29]  Soheil Ghiasi,et al.  Recovering the fetal signal in transabdominal fetal pulse oximetry , 2018, Smart Health.

[30]  P. King,et al.  Design Of Pulse Oximeters , 1998, IEEE Engineering in Medicine and Biology Magazine.

[31]  J. Martin,et al.  Births: Final Data for 2017. , 2018, National vital statistics reports : from the Centers for Disease Control and Prevention, National Center for Health Statistics, National Vital Statistics System.

[32]  Beer Bestimmung der Absorption des rothen Lichts in farbigen Flüssigkeiten , 1852 .

[33]  L. Nilsson,et al.  Macrocirculation is not the sole determinant of respiratory induced variations in the reflection mode photoplethysmographic signal. , 2003, Physiological measurement.

[34]  D B Swedlow,et al.  A multicenter controlled trial of fetal pulse oximetry in the intrapartum management of nonreassuring fetal heart rate patterns. , 2000, American journal of obstetrics and gynecology.

[35]  K. Belanger,et al.  Indications Contributing to the Increasing Cesarean Delivery Rate , 2011, Obstetrics and gynecology.

[36]  H. Aiello,et al.  Fetal Doppler mechanical PR interval: correlation with fetal heart rate, gestational age and fetal sex , 2009, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[37]  Soheil Ghiasi,et al.  Transabdominal fetal pulse oximetry: The case of fetal signal optimization , 2017, 2017 IEEE 19th International Conference on e-Health Networking, Applications and Services (Healthcom).

[38]  A D Gordon,et al.  Near-infrared optical properties of ex vivo human uterus determined by the Monte Carlo inversion technique. , 1999, Physics in medicine and biology.