SSO of DFIG‐based wind farm integrated by a hybrid series compensator

Doubly-fed induction generator (DFIG)-based wind farms integrated by series compensated transmission lines are confronting with the problem of subsynchronous oscillation (SSO). In this study, the configuration and control stratagem of hybrid series compensator composed of a static synchronous series compensator (SSSC) and a fixed capacitor are proposed, and the SSO of DFIG-based wind farm integrated by a hybrid series compensator are studied. The results reveal that the SSO risk of the system is lower by using the hybrid series compensator, and the SSO damping is larger with a higher proportion of SSSC in the hybrid series compensator, as well as with a larger compensation impedance or voltage of SSSC. The research is supposed to be helpful for the planning and operating of the power system with large-scale wind farms integrated.

[1]  Shijie Cheng,et al.  Improved Complex Torque Coefficient Method Using CPCM for Multi-Machine System SSR Analysis , 2014, IEEE Transactions on Power Systems.

[2]  J. Svensson,et al.  On Control of Static Synchronous Series Compensator for SSR Mitigation , 2007, IEEE Transactions on Power Electronics.

[3]  Liang Wang,et al.  Investigation of SSR in Practical DFIG-Based Wind Farms Connected to a Series-Compensated Power System , 2015, IEEE Transactions on Power Systems.

[4]  A. Joshi,et al.  Torsional Interaction Studies on a Power System Compensated by SSSC and Fixed Capacitor , 2002, IEEE Power Engineering Review.

[5]  Jin Yu Wen,et al.  Subsynchronous Interaction and its Mitigation in DFIG-Based Wind Farm and Turbine-Generator Bundled Systems , 2013 .

[6]  Boon-Teck Ooi,et al.  Series compensation of radial power system by a combination of SSSC and dielectric capacitors , 2005, IEEE Transactions on Power Delivery.

[7]  Jinyu Wen,et al.  A practical method to construct network state equations in multi-machine system SSR study , 2014 .

[8]  Jorge A. Solsona,et al.  Sub-Synchronous Interaction Damping Control for DFIG Wind Turbines , 2015, IEEE Transactions on Power Systems.

[9]  Arindam Ghosh,et al.  Torsional oscillation studies in an SSSC compensated power system , 2000 .

[10]  Hui Liu,et al.  Quantitative SSR Analysis of Series-Compensated DFIG-Based Wind Farms Using Aggregated RLC Circuit Model , 2017, IEEE Transactions on Power Systems.

[11]  Laszlo Gyugyi,et al.  Static Synchronous Series Compensator: A Solid-State Approach to the Series Compensation of Transmission Lines , 1997 .

[12]  R. Pillay Carpanen,et al.  An improved SSSC-based power flow controller design method and its impact on torsional interaction , 2012 .

[13]  Yunjian Xu,et al.  Kalman Filter Based Detection and Mitigation of Subsynchronous Resonance with SSSC , 2017, IEEE Transactions on Power Systems.