Impact of Wind and Solar on the Value of Energy Storage

This analysis evaluates how the value of energy storage changes when adding variable generation (VG) renewable energy resources to the grid. A series of VG energy penetration scenarios from 16% to 55% were generated for a utility system in the western United States. This operational value of storage (measured by its ability to reduce system production costs) was estimated in each VG scenario, considering provision of different services and with several sensitivities to fuel price and generation mix. Overall, the results found that the presence of VG increases the value of energy storage by lowering off-peak energy prices more than on-peak prices, leading to a greater opportunity to arbitrage this price difference. However, significant charging from renewables, and consequently a net reduction in carbon emissions, did not occur until VG penetration was in the range of 40%-50%. Increased penetration of VG also increases the potential value of storage when providing reserves, mainly by increasing the amount of reserves required by the system. Despite this increase in value, storage may face challenges in capturing the full benefits it provides. Due to suppression of on-/off-peak price differentials, reserve prices, and incomplete capture of certain system benefits (such as the cost of power plant starts), the revenue obtained by storage in a market setting appears to be substantially less than the net benefit (reduction in production costs) provided to the system. Furthermore, it is unclear how storage will actually incentivize large-scale deployment of renewables needed to substantially increase VG penetration. This demonstrates some of the additional challenges for storage deployed in restructured energy markets.

[1]  Aidan Tuohy,et al.  Pumped storage in systems with very high wind penetration , 2011 .

[2]  P. Denholm,et al.  Value of Energy Storage for Grid Applications , 2013 .

[3]  Pooya Soltantabar Annual Energy Outlook , 2015 .

[4]  Aron Dobos,et al.  System Advisor Model, SAM 2011.12.2: General Description , 2012 .

[5]  Sandia Report,et al.  Maui energy storage study. , 2012 .

[6]  Paul Denholm,et al.  Grid flexibility and storage required to achieve very high penetration of variable renewable electricity , 2011 .

[7]  Assessing Storage Value in Electricity Markets , 2013 .

[8]  P. Denholm,et al.  Market and Policy Barriers to Deployment of Energy Storage , 2012 .

[9]  Willett Kempton,et al.  Vehicle-to-grid power fundamentals: Calculating capacity and net revenue , 2005 .

[10]  D. Lew,et al.  The Western Wind and Solar Integration Study Phase 2 , 2013 .

[11]  Jerry W. Ginn,et al.  Final report on testing of ACONF technology for the US Coast Guard National Distress Systems : a study for the DOE Energy Storage Systems Program. , 2005 .

[12]  R. Sioshansi Increasing the Value of Wind with Energy Storage , 2011 .

[13]  Michael Milligan,et al.  Operating Reserves and Variable Generation , 2011 .

[14]  Sandia Report,et al.  Installation of the First Distributed Energy Storage System (DESS) at American Electric Power (AEP) A Study for the DOE Energy Storage Systems Program , 2007 .

[15]  Paul Denholm,et al.  The value of compressed air energy storage with wind in transmission-constrained electric power systems , 2009 .

[16]  Paul Denholm,et al.  A Dynamic Programming Approach to Estimate the Capacity Value of Energy Storage , 2014, IEEE Transactions on Power Systems.

[17]  Kara Clark,et al.  Western Wind and Solar Integration Study , 2011 .