Understanding power transformer frequency response analysis signatures

This paper presents a comprehensive analysis of the effects of various faults on the FRA signatures of a transformer simulated by a high-frequency model. The faults were simulated through changes in the values of some of the electrical components in the model. It was found that radial displacement of a winding alters the FRA signature over the entire frequency range (10 Hz-1 MHz), whereas changes due to axial displacement occur only at frequencies above 200 kHz. A Table listing various transformer faults and the associated changes in the FRA signature was compiled and could be used in the formulation of standard codes for power transformer FRA signature interpretation.

[1]  Ankur Teredesai,et al.  A pervasive Dietary Data Recording System , 2011, 2011 IEEE International Conference on Pervasive Computing and Communications Workshops (PERCOM Workshops).

[2]  W H Tang,et al.  Detection of minor winding deformation fault in high frequency range for power transformer , 2010, IEEE PES General Meeting.

[3]  L. Satish,et al.  An effort to understand what factors affect the transfer function of a two-winding transformer , 2005, IEEE Transactions on Power Delivery.

[4]  S. Friel,et al.  The Health Equity Dimensions of Urban Food Systems , 2007, Journal of Urban Health.

[5]  Marc Levoy,et al.  QSplat: a multiresolution point rendering system for large meshes , 2000, SIGGRAPH.

[6]  Stefan Tenbohlen,et al.  Experimental and theoretical investigation of disc space variation in real high-voltage windings using transfer function method , 2010 .

[7]  Birgitte Bak-Jensen,et al.  Detection of faults and ageing phenomena in transformers by transfer functions , 1995 .

[8]  S.M. Gubanski,et al.  Exploring possibilities for characterization of power transformer insulation by frequency response analysis (FRA) , 2006, IEEE Transactions on Power Delivery.

[9]  W.H. Tang,et al.  Transformer Core Parameter Identification Using Frequency Response Analysis , 2010, IEEE Transactions on Magnetics.

[10]  Ajay Divakaran,et al.  Automatic food documentation and volume computation using digital imaging and electronic transmission. , 2010, Journal of the American Dietetic Association.

[11]  Niloy J. Mitra,et al.  Symmetry in 3D Geometry: Extraction and Applications , 2013, Comput. Graph. Forum.

[12]  Bryant T Karras,et al.  Mobile eHealth Interventions for Obesity: A Timely Opportunity to Leverage Convergence Trends , 2005, Journal of medical Internet research.

[13]  E J Delp,et al.  Use of technology in children’s dietary assessment , 2009, European Journal of Clinical Nutrition.

[14]  K. Feser,et al.  Transfer Function Method to Diagnose Axial Displacement and Radial Deformation of Transformer Winding , 2002, IEEE Power Engineering Review.

[15]  Gerard Ledwich,et al.  Identification of high frequency transformer equivalent circuit using Matlab from frequency domain data , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[16]  W. J. McNutt,et al.  Power Transformen Short-Circuit Strength - Requirements, Design, and Demonstration , 1970 .

[17]  D.M. Sofian,et al.  Interpretation of Transformer FRA Responses— Part I: Influence of Winding Structure , 2009, IEEE Transactions on Power Delivery.

[18]  A. Abu-Siada,et al.  A new method for analysing transformer condition using frequency response analysis , 2011, 2011 IEEE Power and Energy Society General Meeting.

[19]  E.P. Dick,et al.  Transformer Diagnostic Testing by Frequuency Response Analysis , 1978, IEEE Transactions on Power Apparatus and Systems.

[20]  A. Abu-Siada,et al.  A Novel Online Technique to Detect Power Transformer Winding Faults , 2012, IEEE Transactions on Power Delivery.

[21]  C A Platero,et al.  Influence of Rotor Position in FRA Response for Detection of Insulation Failures in Salient-Pole Synchronous Machines , 2011, IEEE Transactions on Energy Conversion.

[22]  David S. Ebert,et al.  Volume estimation using food specific shape templates in mobile image-based dietary assessment , 2011, Electronic Imaging.

[23]  S. D. Mitchell,et al.  Modeling Power Transformers to Support the Interpretation of Frequency-Response Analysis , 2011, IEEE Transactions on Power Delivery.

[24]  S. Burak Gokturk,et al.  A Time-Of-Flight Depth Sensor - System Description, Issues and Solutions , 2004, 2004 Conference on Computer Vision and Pattern Recognition Workshop.

[25]  E. J. Figueroa MANAGING AN AGING FLEET OF TRANSFORMERS , 2009 .

[26]  N. Abeywickrama,et al.  High-Frequency Modeling of Power Transformers for Use in Frequency Response Analysis (FRA) , 2008, IEEE Transactions on Power Delivery.

[27]  David S. Ebert,et al.  Automatic portion estimation and visual refinement in mobile dietary assessment , 2010, Electronic Imaging.

[28]  Ankur Teredesai,et al.  Dietary intake assessment using integrated sensors and software , 2012, Electronic Imaging.

[29]  L. M. Geldenhuis Power transformer life management , 2005 .

[30]  Carl Gibbons,et al.  Foods prepared outside the home: association with selected nutrients and body mass index in adult Australians , 2002, Public Health Nutrition.

[31]  A. Abu-Siada,et al.  A novel algorithm to detect internal transformer faults , 2011, 2011 IEEE Power and Energy Society General Meeting.

[32]  Wensheng Gao,et al.  Deformation analysis of transformer winding by structure parameter , 2003, Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (Cat. No.03CH37417).

[33]  N. Abeywickrama,et al.  Effect of Core Magnetization on Frequency Response Analysis (FRA) of Power Transformers , 2008, IEEE Transactions on Power Delivery.

[34]  M. S. Naderi,et al.  FRA vs. short circuit impedance measurement in detection of mechanical defects within large power transformer , 2012, 2012 IEEE International Symposium on Electrical Insulation.

[35]  Q. H. Wu,et al.  Transformer winding condition assessment using frequency response analysis and evidential reasoning , 2010 .

[36]  David G. Lowe,et al.  Distinctive Image Features from Scale-Invariant Keypoints , 2004, International Journal of Computer Vision.

[37]  K. Ragavan,et al.  Localization of Changes in a Model Winding Based on Terminal Measurements: Experimental Study , 2007, IEEE Transactions on Power Delivery.

[38]  A A Reykherdt,et al.  Case studies of factors influencing frequency response analysis measurements and power transformer diagnostics , 2011, IEEE Electrical Insulation Magazine.

[39]  Corby K. Martin,et al.  Quantification of food intake using food image analysis , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[40]  G. B. Gharehpetian,et al.  Buckling severity diagnosis in power transformer windings using Euclidean Distance classifier , 2011, 2011 19th Iranian Conference on Electrical Engineering.

[41]  Gerard Ledwich,et al.  Locating transformer faults through sensitivity analysis of high frequency modeling using transfer function approach , 1996, Conference Record of the 1996 IEEE International Symposium on Electrical Insulation.

[42]  Stefan Tenbohlen,et al.  Mathematical Comparison Methods to Assess Transfer Functions of Transformers to Detect Different Types of Mechanical Faults , 2010, IEEE Transactions on Power Delivery.

[43]  Mingui Sun,et al.  3D/2D model-to-image registration for quantitative dietary assessment , 2012, 2012 38th Annual Northeast Bioengineering Conference (NEBEC).

[44]  A.J. Vandermaar,et al.  Improved detection of power transformer winding movement by extending the FRA high frequency range , 2005, IEEE Transactions on Power Delivery.

[45]  Zhongdong Wang,et al.  Interpretation of Transformer FRA Responses— Part II: Influence of Transformer Structure , 2010, IEEE Transactions on Power Delivery.

[46]  Zhengyou Zhang,et al.  A Flexible New Technique for Camera Calibration , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[47]  Mohammadreza Barzegaran,et al.  Detecting the Position of Winding Short Circuit Faults in Transformer Using High Frequency Analysis , 2008 .