A benchmark study with sealchip planar patch-clamp technology.

Although conventional patch-clamp methods provide high information content, they are labor-intensive and suffer from low throughput and high overall cost. Several approaches for achieving high throughput electrophysiology are under development, among which microchip-based patch-clamp systems uniquely achieve a higher degree of miniaturization, faster perfusion and mixing, and lower reagent cost without losing information content. The goal of this study was to establish a benchmark for our biochip technology with 52 chips tested sequentially. We demonstrate that our microfabrication and processing technology is sufficiently mature to produce a consistent hole size. We further demonstrate high-quality planar whole-cell patch clamping with >75% overall success rate at achieving gigaohm seals, followed by stable whole-cell access lasting at least 15 min with access resistance (Ra) below 15 MOmega and membrane resistance (Rm) above 200 MOmega. These biochips are ideally suited for high throughput compound screening for ion channel targets.

[1]  Paul B Bennett,et al.  High throughput ion-channel pharmacology: planar-array-based voltage clamp. , 2003, Assay and drug development technologies.

[2]  M. Reed,et al.  Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells. , 2002, Biosensors & bioelectronics.

[3]  Horst Vogel,et al.  Chip based biosensor for functional analysis of single ion channels , 2000 .

[4]  Derek J Trezise,et al.  IonWorks™ HT: A New High-Throughput Electrophysiology Measurement Platform , 2003, Journal of biomolecular screening.

[5]  Y. Huang,et al.  Electrode design for negative dielectrophoresis , 1991 .

[6]  L. Mattheakis,et al.  Assay technologies for screening ion channel targets. , 2001, Current opinion in drug discovery & development.

[7]  D. O. Rudin,et al.  Reconstitution of Cell Membrane Structure in vitro and its Transformation into an Excitable System , 1962, Nature.

[8]  H. Ussing,et al.  Active transport of sodium as the source of electric current in the short-circuited isolated frog skin. Reprinted from Acta. Physiol. Scand. 23: 110-127, 1951. , 1999, Journal of the American Society of Nephrology : JASN.

[9]  B. Sakmann,et al.  Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches , 1981, Pflügers Archiv.

[10]  Lei Wu,et al.  Ion-channel assay technologies: quo vadis? , 2001, Drug discovery today.

[11]  H H USSING,et al.  Active transport of sodium as the source of electric current in the short-circuited isolated frog skin. , 1951, Acta physiologica Scandinavica.

[12]  Robert H Blick,et al.  Whole cell patch clamp recording performed on a planar glass chip. , 2002, Biophysical journal.

[13]  Alfred Stett,et al.  CYTOCENTERING: a novel technique enabling automated cell-by-cell patch clamping with the CYTOPATCH chip. , 2003, Receptors & channels.

[14]  D. Noble,et al.  Reconstruction of the repolarization process in cardiac Purkinje fibres based on voltage clamp measurements of membrane current , 1969, The Journal of physiology.

[15]  F Bezanilla,et al.  Bilayer reconstitution of voltage-dependent ion channels using a microfabricated silicon chip. , 2001, Biophysical journal.

[16]  C. Trautmann,et al.  Microstructured glass chip for ion-channel electrophysiology. , 2001, Physical review. E, Statistical, nonlinear, and soft matter physics.