Suppression of parallel resonance and mitigation of harmonic distortion through shunt active power compensation

Abstract In this contribution a solution to the parallel resonance problem that can be present in practical applications of shunt Active Power Filter (APF) compensation is proposed. The proposed solution involves turning the shunt APF scheme of compensation into a Shunt Hybrid Filter (SHF) configuration. A Linear Quadratic Regulator (LQR)-based switching controller was specifically designed for this hybrid scheme of compensation, maintaining stringent performance requirements on the tracking of filtering currents and the draining of the harmonic ripple currents. Results obtained with Matlab/Simulink® illustrate an effective and sound system of compensation which also reduces the necessary KVA rating of the APF.

[1]  A. Medina-Rios,et al.  An Active Power Filter in Phase Coordinates for Harmonic Mitigation , 2007, IEEE Transactions on Power Delivery.

[2]  Arindam Ghosh,et al.  Load compensating DSTATCOM in weak AC systems , 2003 .

[3]  W. M. Grady,et al.  Survey of active power line conditioning methodologies , 1990 .

[4]  Arindam Ghosh,et al.  Power Quality Enhancement Using Custom Power Devices , 2002 .

[5]  Bong-Hwan Kwon,et al.  Shunt active filter for reactive power compensation , 2001 .

[6]  Patricia Liliana Arnera,et al.  Hybrid Active Filter for Reactive and Harmonics Compensation in a Distribution Network , 2009, IEEE Transactions on Industrial Electronics.

[7]  Kamal Al-Haddad,et al.  A review of active filters for power quality improvement , 1999, IEEE Trans. Ind. Electron..

[8]  Mauricio Aredes,et al.  Three-phase four-wire shunt active filter control strategies , 1997 .

[9]  B. Anderson,et al.  Linear Optimal Control , 1971 .

[10]  Rogerio Azevedo Diniz,et al.  Distributed series/hybrid-shunt compensation for harmonic mitigation in commercial facilities , 2014, 2014 International Power Electronics Conference (IPEC-Hiroshima 2014 - ECCE ASIA).

[11]  Alvaro Luna,et al.  Grid harmonic detection and system resonances indentification in wave power plant applications , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[12]  Bhim Singh,et al.  Hybrid filters for power quality improvement , 2005 .

[13]  Paolo Mattavelli,et al.  Comparison of current control techniques for active filter applications , 1998, IEEE Trans. Ind. Electron..

[14]  Babak Badrzadeh,et al.  Practical Experiences and Mitigation Methods of Harmonics in Wind Power Plants , 2013, IEEE Transactions on Industry Applications.

[15]  G.W. Chang,et al.  A comparative study of active power filter reference compensation approaches , 2002, IEEE Power Engineering Society Summer Meeting,.

[16]  R. D. Patidar,et al.  Digital Signal Processor Based Shunt Active Filter Controller for Customer-generated Harmonics and Reactive Power Compensation , 2010 .

[17]  M. Sydulu,et al.  S-transform-based Hybrid Active Filter for Mitigation of Current Harmonics , 2009 .

[18]  José M.F. Ferreira,et al.  An Active Power Filter with Direct Current Control for Power Quality Conditioning , 2008 .

[19]  Hirofumi Akagi,et al.  Comparisons in circuit configuration and filtering performance between hybrid and pure shunt active filters , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..

[20]  Enrique Acha,et al.  Power Systems Harmonics , 2001 .

[21]  Bhim Singh,et al.  Computer-Aided Modeling and Simulation of Active Power Filters , 1999 .

[22]  Seppo J. Ovaska,et al.  Current reference generator for 50-Hz and 16.7-Hz shunt active power filters , 2010 .

[23]  J. Chicharo,et al.  A NOVEL EQUAL SAMPLING SWITCHING STRATEGY FOR ACTIVE POWER FILTERS , 1994 .

[24]  Sewan Choi,et al.  A reduced-rating hybrid filter to suppress neutral current harmonics in three-phase four-wire systems , 2004, IEEE Transactions on Industrial Electronics.

[25]  Ahmed F. Zobaa Letter to the Editor: Optimal Sizing of the Passive Filter's Elements in Hybrid Active Filters , 2007 .