Feasibility of differential geometry-based features in detection of anatomical feature points on patient surfaces in range image-guided radiation therapy

PurposeTo investigate the feasibility of differential geometry features in the detection of anatomical feature points on a patient surface in infrared-ray-based range images in image-guided radiation therapy.MethodsThe key technology was to reconstruct the patient surface in the range image, i.e., point distribution with three-dimensional coordinates, and characterize the geometrical shape at every point based on curvature features. The region of interest on the range image was extracted by using a template matching technique, and the range image was processed for reducing temporal and spatial noise. Next, a mathematical smooth surface of the patient was reconstructed from the range image by using a non-uniform rational B-splines model. The feature points were detected based on curvature features computed on the reconstructed surface. The framework was tested on range images acquired by a time-of-flight (TOF) camera and a Kinect sensor for two surface (texture) types of head phantoms A and B that had different anatomical geometries. The detection accuracy was evaluated by measuring the residual error, i.e., the mean of minimum Euclidean distances (MMED) between reference (ground truth) and detected feature points on convex and concave regions.ResultsThe MMEDs obtained using convex feature points for range images of the translated and rotated phantom A were $$1.79 \pm 0.53$$1.79±0.53 and $$1.97\pm 0.21\,\hbox {mm}$$1.97±0.21mm, respectively, using the TOF camera. For the phantom B, the MMEDs of the convex and concave feature points were $$0.26\pm 0.09$$0.26±0.09 and $$0.52\pm 0.12$$0.52±0.12 mm, respectively, using the Kinect sensor. There was a statistically significant difference in the decreased MMED for convex feature points compared with concave feature points $$(P<0.001)$$(P<0.001).ConclusionsThe proposed framework has demonstrated the feasibility of differential geometry features for the detection of anatomical feature points on a patient surface in range image-guided radiation therapy.

[1]  Frédo Durand,et al.  A Fast Approximation of the Bilateral Filter Using a Signal Processing Approach , 2006, ECCV.

[2]  Shinichi Shimizu,et al.  Real-time tumour-tracking radiotherapy , 1999, The Lancet.

[3]  Maurício Pamplona Segundo,et al.  Automatic Face Segmentation and Facial Landmark Detection in Range Images , 2010, IEEE Transactions on Systems, Man, and Cybernetics, Part B (Cybernetics).

[4]  Pietro Cerveri,et al.  Local Shape Similarity and Mean-Shift Curvature for Deformable Surface Mapping of Anatomical Structures , 2014, IEEE Transactions on Biomedical Engineering.

[5]  A. Brahme,et al.  4D laser camera for accurate patient positioning, collision avoidance, image fusion and adaptive approaches during diagnostic and therapeutic procedures. , 2008, Medical physics.

[6]  Gady Agam,et al.  A sampling framework for accurate curvature estimation in discrete surfaces , 2005, IEEE Transactions on Visualization and Computer Graphics.

[7]  Hui-Yun Chen,et al.  Shape and curvedness analysis of brain morphology using human fetal magnetic resonance images in utero , 2013, Brain Structure and Function.

[8]  Hiroshi Honda,et al.  Breath-hold monitoring and visual feedback for radiotherapy using a charge-coupled device camera and a head-mounted display: system development and feasibility , 2008, Radiation Medicine.

[9]  Andrea J. van Doorn,et al.  Surface shape and curvature scales , 1992, Image Vis. Comput..

[10]  John M Buatti,et al.  Optically guided patient positioning techniques. , 2005, Seminars in radiation oncology.

[11]  David Sarrut,et al.  Multi-dimensional respiratory motion tracking from markerless optical surface imaging based on deformable mesh registration , 2012, Physics in medicine and biology.

[12]  Elli Angelopoulou,et al.  Fast time-of-flight camera based surface registration for radiotherapy patient positioning. , 2011, Medical physics.

[13]  Stacey M Benson,et al.  Facial anthropometric differences among gender, ethnicity, and age groups. , 2010, The Annals of occupational hygiene.

[14]  Timothy D. Solberg,et al.  Infrared patient positioning for stereotactic radiosurgery of extracranial tumors , 1999, Comput. Biol. Medicine.

[15]  Les A. Piegl,et al.  The NURBS book (2nd ed.) , 1997 .

[16]  Les A. Piegl,et al.  The NURBS Book , 1995, Monographs in Visual Communication.

[17]  Paul F. Whelan,et al.  3D Facial Landmark Localization Using Combinatorial Search and Shape Regression , 2012, ECCV Workshops.

[18]  Roberto Manduchi,et al.  Bilateral filtering for gray and color images , 1998, Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271).

[19]  Stephan Hussmann,et al.  Real-Time Motion Artifact Suppression in TOF Camera Systems , 2011, IEEE Transactions on Instrumentation and Measurement.

[20]  H. J. Kang,et al.  Development of an automated region of interest selection method for 3D surface monitoring of head motion. , 2012, Medical physics.

[21]  Lawrence H. Staib,et al.  Shape-based 3D surface correspondence using geodesics and local geometry , 2000, Proceedings IEEE Conference on Computer Vision and Pattern Recognition. CVPR 2000 (Cat. No.PR00662).

[22]  R. E. Kalman,et al.  A New Approach to Linear Filtering and Prediction Problems , 2002 .

[23]  Jean L. Peng,et al.  Dosimetric consequences of rotational setup errors with direct simulation in a treatment planning system for fractionated stereotactic radiotherapy , 2011, Journal of applied clinical medical physics.

[24]  Patrick A Kupelian,et al.  Optical tracking technology in stereotactic radiation therapy. , 2007, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[25]  J. Mechalakos,et al.  Motion monitoring for cranial frameless stereotactic radiosurgery using video-based three-dimensional optical surface imaging. , 2011, Medical physics.

[26]  Tejinder Kataria,et al.  Image Guidance in Radiation Therapy: Techniques and Applications , 2014, Radiology research and practice.

[27]  Lena Maier-Hein,et al.  Pose-independent surface matching for intra-operative soft-tissue marker-less registration , 2014, Medical Image Anal..

[28]  A. Pressley Elementary Differential Geometry , 2000 .

[29]  H Alasti,et al.  Portal imaging for evaluation of daily on-line setup errors and off-line organ motion during conformal irradiation of carcinoma of the prostate. , 2001, International journal of radiation oncology, biology, physics.

[30]  Jatinder R Palta,et al.  Evaluation of intrafraction patient movement for CNS and head & neck IMRT. , 2004, Medical physics.

[31]  Ioannis A. Kakadiaris,et al.  Using Facial Symmetry to Handle Pose Variations in Real-World 3D Face Recognition , 2011, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[32]  Guang Li,et al.  Clinical experience with two frameless stereotactic radiosurgery (fSRS) systems using optical surface imaging for motion monitoring , 2015, Journal of applied clinical medical physics.

[33]  Shinichi Shimizu,et al.  Real-time tumor-tracking radiotherapy for adrenal tumors. , 2008, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.