Closed ampoule isothermal microcalorimetry for continuous real-time detection and evaluation of cultured mammalian cell activity and responses.

Closed ampoule isothermal microcalorimetry (IMC) is a simple, powerful, nondestructive, and convenient technique that allows continuous, real-time detection and evaluation of cultured cell activity and responses. At a selected set temperature, IMC measures the heat flow between a sample and a heat sink and compares it to the heat-flow between a thermally inactive reference and the heat sink. Since heat flow rates are proportional to the rates of chemical reactions and changes of state, IMC provides a means for dynamically following these processes in any type of specimen - including ones containing cultured cells. The ability of IMC instruments to provide measurements in the microwatt (μJ/s) range allows one to detect and follow the activity (including replication) of low numbers of cells in culture (ca. 10(3)-10(5), depending on cell type). Closed ampoule IMC is increasingly being used in medical and environmental sciences. While a closed ampoule imposes limitations, it conversely provides simplicity and excellent control. Also, it is still usually possible with closed ampoules to follow mammalian cell activity and replication for several days. This chapter provides an overview of IMC measurement principles and provides examples of the use of IMC for evaluating cultured human and other mammalian cell activity and responses.

[1]  H. Olsson,et al.  Heat production rate in blood lymphocytes as a prognostic factor in non‐Hodgkin's lymphoma , 1990, European journal of haematology.

[2]  I. Wadsö Characterization of microbial activity in soil by use of isothermal microcalorimetry , 2009 .

[3]  R. Ringert,et al.  Microcalorimetric measurements carried out on isolated tumorous and nontumorous tissue samples from organs in the urogenital tract in comparison to histological and impulse-cytophotometric investigations , 2004, Urological Research.

[4]  James S. Chickos,et al.  Reference Materials for Calorimetry and Differential Thermal Analysis , 1999 .

[5]  A. W. van Herwaarden,et al.  Overview of calorimeter chips for various applications , 2005 .

[6]  A. U. Daniels,et al.  A Comparison Between (3H)-thymidine Incorporation and Isothermal Microcalorimetry for the Assessment of Antigen-induced Lymphocyte Proliferation , 2009, Immunological investigations.

[7]  I. Wadsö,et al.  Microcalorimetric measurements of heat production in human erythrocytes. IV. Comparison between different calorimetric techniques, suspension media, and preparation methods. , 1976, Scandinavian journal of clinical and laboratory investigation.

[8]  D. Wirz,et al.  Isothermal micro calorimetry – a new method for MIC determinations: results for 12 antibiotics and reference strains of E. coli and S. aureus , 2009, BMC Microbiology.

[9]  A. U. Daniels,et al.  Use of isothermal heat-conduction microcalorimetry (IHCMC) for the evaluation of synthetic biomaterials. , 2003, Journal of biomedical materials research. Part B, Applied biomaterials.

[10]  L. Sun,et al.  Microcalorimetric studies on the antimicrobial actions of different cephalosporins , 2008 .

[11]  K. Levin Heat production by leucocytes and thrombocytes measured with a flow microcalorimeter in normal man and during thyroid dysfunction. , 1971, Clinica chimica acta; international journal of clinical chemistry.

[12]  P. Fürst,et al.  Thermogenesis of white adipocytes: a novel method allowing long-term microcalorimetric investigations. , 1991, Journal of biochemical and biophysical methods.

[13]  L. Wadsö Isothermal Microcalorimetry. Current problems and prospects , 2001 .

[14]  I. Lamprecht Calorimetry and thermodynamics of living systems , 2003 .

[15]  P. Nilsson-ehle,et al.  Heat production by adipocytes from obese subjects before and after weight reduction. , 1982, Metabolism: clinical and experimental.

[16]  P. Bataillard,et al.  Calorimetric sensing in bioanalytical chemistry : principles, applications and trends , 1993 .

[17]  I. Wadsö Isothermal microcalorimetry in applied biology , 2002 .

[18]  P. Fürst,et al.  Thermogenesis and metabolism of human white adipocytes in gel culture. , 1992, Clinical nutrition.

[19]  W. Cun-xin,et al.  Microcalorimetric study of virus infection; The effects of hyperthermia and 1b recombinant homo interferon on the infection process of BHK-21 cells by foot and mouth disease virus , 2005 .

[20]  G. Svehla,et al.  Biochemical and clinical applications of thermometric and thermal analysis , 1982 .

[21]  Peter Kuhn,et al.  Enthalpy array analysis of enzymatic and binding reactions. , 2008, Analytical biochemistry.

[22]  A. Tan,et al.  Microcalorimetric study of antiviral effect of drug. , 1999, Journal of biochemical and biophysical methods.

[23]  W. Sand,et al.  Evaluation of biocide efficacy by microcalorimetric determination of microbial activity in biofilms. , 1998 .

[24]  A. G. Bell,et al.  Enthalpy arrays. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[25]  M. Monti Chapter 6 – In Vitro Thermal Studies of Blood Cells , 1987 .

[26]  James H Brown,et al.  Allometric scaling of metabolic rate from molecules and mitochondria to cells and mammals , 2002, Proceedings of the National Academy of Sciences of the United States of America.

[27]  Y. Guan,et al.  Heat flux and the calorimetric-respirometric ratio as measures of catabolic flux in mammalian cells , 1997 .

[28]  L. Yi,et al.  Microcalorimetric study of Staphylococcus aureus growth affected by selenium compounds , 2002 .

[29]  Olivier Braissant,et al.  Use of isothermal microcalorimetry to monitor microbial activities. , 2010, FEMS microbiology letters.

[30]  Q. Songsheng,et al.  Microcalorimetric study of mitochondria isolated from fish liver tissue , 1996 .