High-Resolution Imaging of Kidney Vascular Corrosion Casts with Nano-CT

Abstract A vascular corrosion cast of an entire mouse kidney was scanned with a modular multiresolution X-ray nanotomography system. Using an isotropic voxel pitch of 0.5 μm, capillary systems such as the vasa recta, peritubular capillaries and glomeruli were clearly resolved. This represents a considerable improvement over corrosion casts scanned with microcomputed tomography systems. The resolving power of this system was clearly demonstrated by the unique observation of a dense, subcapsular mat of capillaries enveloping the entire outer surface of the cortical region. Resolution of glomerular capillaries was comparable to similar models derived from laser scanning confocal microscopy. The high-resolution, large field of view and the three-dimensional nature of the resulting data opens new possibilities for the use of corrosion casting in research.

[1]  John G. Sled,et al.  Analysis of microvasculature in whole kidney specimens using micro-CT , 2004, SPIE Optics + Photonics.

[2]  Kirk Czymmek,et al.  Confocal Microscopy, Computer Modeling, and Quantification of Glomerular Vascular Corrosion Casts , 2006, Microscopy and Microanalysis.

[3]  Alexander Sasov,et al.  Micro-CT of corrosion casts for use in the computer-aided design of microvasculature. , 2009, Tissue engineering. Part C, Methods.

[4]  Erik L Ritman,et al.  The use of microcomputed tomography to study microvasculature in small rodents. , 2002, American journal of physiology. Regulatory, integrative and comparative physiology.

[5]  R Mark Henkelman,et al.  MicroCT scanner performance and considerations for vascular specimen imaging. , 2004, Medical physics.

[6]  M A Konerding,et al.  Three-dimensional analysis of tumour vascular corrosion casts using stereoimaging and micro-computed tomography. , 2010, Microvascular research.

[7]  P. Burri,et al.  Corrosion Cast Analysis of Blood Vessels , 2004 .

[8]  A. Rodríguez-Baeza,et al.  Perivascular structures in corrosion casts of the human central nervous system: A confocal laser and scanning electron microscope study , 1998, The Anatomical record.

[9]  Ectopic transplantation of tissues under the kidney capsule. , 2007, Methods in molecular biology.

[10]  J. Sled,et al.  3D visualisation and quantification by microcomputed tomography of late gestational changes in the arterial and venous feto-placental vasculature of the mouse. , 2007, Placenta.

[11]  V. Cnudde,et al.  Software tools for quantification of X-ray microtomography at the UGCT , 2007 .

[12]  A. Lametschwandtner,et al.  Scanning electron microscopy of vascular corrosion casts--technique and applications: updated review. , 1990, Scanning microscopy.

[13]  Franz Pfeiffer,et al.  High-resolution tomographic imaging of microvessels , 2008, Optical Engineering + Applications.

[14]  R L Becker,et al.  Three-dimensional modeling of renal glomerular capillary networks. , 1997, Analytical and quantitative cytology and histology.

[15]  H. Augustin Methods in Endothelial Cell Biology , 2004, Springer Lab Manuals.