The application accuracy of the NeuroMate robot--A quantitative comparison with frameless and frame-based surgical localization systems.

The NeuroMatetrade mark robot system (Integrated Surgical Systems, Davis, CA) is a commercially available, image-guided, robotic-assisted system used for stereotactic procedures in neurosurgery. In this article, we present a quantitative comparison of the application accuracy of the NeuroMate with that of standard frame-based and frameless stereotactic techniques. The article discusses a five-way application accuracy comparison study. The variables of our comparison and their mean errors are as follows: (1) with the robot in a frame-based configuration, the RMS was 0.86 +/- 0.32 mm; (2) with the robot in the frameless configuration, the RMS was 1.95 +/- 0.44 mm; (3) in a standard stereotactic (ZD) frame-based approach, the RMS was 1.17 +/- 0.25 mm; (4) with an infrared tracking system using the frame for fiducial registration, the RMS was 1.47 +/- 0.45 mm; (5) with an infrared tracking system using screw markers for registration, the RMS was 0.68 +/- 0.26 mm. The study was performed with 2-mm sections of CT scans. These results show that the application accuracy of the frame-based NeuroMate robot is comparable to that of standard localizing systems, whether they are frame-based or infrared tracked.

[1]  P. Grunert,et al.  Accuracy of stereotactic coordinate transformation using a localisation frame and computed tomographic imaging , 1999, Neurosurgical Review.

[2]  E. Stephenson,et al.  Initial United States clinical trial of robotically assisted endoscopic coronary artery bypass grafting. , 2000, The Journal of thoracic and cardiovascular surgery.

[3]  R Perez,et al.  Effect of optical digitizer selection on the application accuracy of a surgical localization system-a quantitative comparison between the OPTOTRAK and flashpoint tracking systems. , 1999, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[4]  Lucia Zamorano,et al.  The Application Accuracy of the NeuroMate Robot—A Quantitative Comparison with Frameless and Frame-Based Surgical Localization Systems , 2002 .

[5]  A M Kadi,et al.  Interactive intraoperative localization using an infrared-based system. , 1994, Stereotactic and functional neurosurgery.

[6]  Jean-Claude Latombe,et al.  Image-Guided Robotic Radiosurgery , 1994, Modelling and Planning for Sensor Based Intelligent Robot Systems.

[7]  P. Grunert,et al.  Accuracy of stereotactic coordinate transformation using a localisation frame and computed tomographic imaging , 1999, Neurosurgical Review.

[8]  James H. Anderson,et al.  A robotic system for percutaneous renal access. , 1997, The Journal of urology.

[9]  R. Maciunas,et al.  The application accuracy of stereotactic frames. , 1994, Neurosurgery.

[10]  Heinrich Niemann,et al.  Three-dimensional computer vision for tooth restoration , 1999, Medical Image Anal..

[11]  G. Buess,et al.  Robotics and systems technology for advanced endoscopic procedures: experiences in general surgery. , 1999, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[12]  R A Buckingham,et al.  Robots in operating theatres , 1995, BMJ.

[13]  J. Anon,et al.  Computer‐aided endoscopic sinus surgery , 1998, The Laryngoscope.

[14]  B. Jaramaz,et al.  Computer Assisted Orthopaedic Surgery: Image Guided and Robotic Assistive Technologies , 1998, Clinical orthopaedics and related research.

[15]  Peter Kazanzides,et al.  Computer-integrated revision total hip replacement surgery: concept and preliminary results , 1999, Medical Image Anal..

[16]  Klaus Radermacher,et al.  CRIGOS: a compact robot for image-guided orthopedic surgery , 1999, IEEE Transactions on Information Technology in Biomedicine.

[17]  P. A. C. Varley Techniques for development of safety-related software for surgical robots , 1999, IEEE Transactions on Information Technology in Biomedicine.

[18]  C Giorgi,et al.  Robot-assisted microscope for neurosurgery. , 1995, Journal of image guided surgery.

[19]  K D Dunlap,et al.  Is the robotic arm a cost-effective surgical tool? , 1998, AORN journal.

[20]  Patrick Pittet,et al.  The Clinical use and Accuracy of the NeuroMate Robot for Open Neurosurgery , 2000 .

[21]  N Hayashi,et al.  Neuronavigation Using an Articulated Arm with a Bayonet Probe on a Computer Graphic Composite of Magnetic Resonance and Computerized Tomography Images , 1998, Minimally invasive neurosurgery : MIN.

[22]  Fernando Diaz,et al.  The Application Accuracy of the Frameless Implantable Marker System and Analysis of Related Affecting Factors , 1998, MICCAI.