Two-dimensional restoration of single photon emission computed tomography images using the Kalman filter

The discrete filtered backprojection (DFBP) algorithm used for the reconstruction of single photon emission computed tomography (SPECT) images affects image quality because of the operations of filtering and discretization. The discretization of the filtered backprojection process can cause the modulation transfer function (MTF) of the SPECT imaging system to be anisotropic and nonstationary, especially near the edges of the camera's field of view. The use of shift-invariant restoration techniques fails to restore large images because these techniques do not account for such variations in the MTF. This study presents the application of a two-dimensional (2D) shift-variant Kalman filter for post-reconstruction restoration of SPECT slices. This filter was applied to SPECT images of a hollow cylinder phantom; a resolution phantom; and a large, truncated cone phantom containing two types of cold spots, a sphere, and a triangular prism. The images were acquired on an ADAC GENESYS camera. A comparison was performed between results obtained by the Kalman filter and those obtained by shift-invariant filters. Quantitative analysis of the restored images performed through measurement of root mean squared errors shows a considerable reduction in error of Kalman-filtered images over images restored using shift-invariant methods.

[1]  Michael A. King,et al.  Investigation of the stationarity of the modulation transfer function and the scatter fraction in conjugate view SPECT restoration filtering , 1989 .

[2]  Rangaraj M. Rangayyan,et al.  Use of the geometric mean of opposing planar projections in pre-reconstruction restoration of SPECT images , 1992 .

[3]  P W Doherty,et al.  Digital restoration of indium-111 and iodine-123 SPECT images with optimized Metz filters. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  S. Larsson,et al.  Generalized scatter correction method in SPECT using point scatter distribution functions. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[5]  Masato Nakajima,et al.  Correction method for collimator effect of ECT , 1986, Systems and Computers in Japan.

[6]  J. Woods,et al.  Model-based segmentation and space-variant restoration of blurred images by decision-directed filtering , 1988 .

[7]  Thomas F. Budinger,et al.  The Use of Filtering Methods to Compensate for Constant Attenuation in Single-Photon Emission Computed Tomography , 1981 .

[8]  M. King,et al.  Deconvolution using orthogonal polynomials in nuclear medicine: a method for forming quantitative functional images from kinetic studies. , 1990, IEEE transactions on medical imaging.

[9]  Joseph W. Goodman,et al.  Fundamental Limitations In Linear Invariant Restoration Of Atmospherically Degraded Images , 1976, Other Conferences.

[10]  H. Murayama,et al.  Convolutional image reconstruction for quantitative single photon emission computed tomography , 1984 .

[11]  Kenneth M. Hanson,et al.  The Characteristics of Computed Tomographic Reconstruction Noise and Their Effect on Detectability , 1978 .

[12]  Ronald J. Jaszczak,et al.  Physical Factors Affecting Quantitative Measurements Using Camera-Based Single Photon Emission Computed Tomography (Spect) , 1981, IEEE Transactions on Nuclear Science.

[13]  Interactions of Collimation, Sampling and Filtering on Spect Spatial Resolution , 1984, IEEE Transactions on Nuclear Science.

[14]  M A King,et al.  Relative importance of the error sources in Wiener restoration of scintigrams. , 1990, IEEE Transactions on Medical Imaging.

[15]  J. Woods,et al.  Kalman filtering in two dimensions: Further results , 1981 .

[16]  B. C. Penney,et al.  Restoration of combined conjugate images in SPECT: comparison of a new Wiener filter and the image-dependent Metz filter , 1990 .

[17]  S Cordier,et al.  A study of the application of a deconvolution method to scintigraphy. , 1979, Physics in medicine and biology.

[18]  Kalman restoration of SPECT images , 1992, 1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[19]  Rangaraj M. Rangayyan,et al.  Preconstruction restoration of myocardial single photon emission computed tomography images , 1992, IEEE Trans. Medical Imaging.

[20]  R. Rangayyan,et al.  Three-dimensional restoration of single photon emission computed tomography images , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[21]  William R. Hendee,et al.  Improvement of Lesion Detection in Scintigraphic Images by SVD Techniques for Resolution Recovery , 1986, IEEE Transactions on Medical Imaging.

[22]  John W. Woods,et al.  Two-dimensional Kalman filtering , 1981 .

[23]  M. Morf,et al.  New results in 2-D systems theory, part II: 2-D state-space models—Realization and the notions of controllability, observability, and minimality , 1977, Proceedings of the IEEE.

[24]  Charles W. Therrien,et al.  A direct algorithm for computing 2-D AR power spectrum estimates , 1989, IEEE Trans. Acoust. Speech Signal Process..

[25]  M A King,et al.  Characterization of the modulation transfer function of discrete filtered backprojection. , 1989, IEEE transactions on medical imaging.

[26]  Mahmood R. Azimi-Sadjadi,et al.  Two-dimensional block Kalman filtering for image restoration , 1987, IEEE Trans. Acoust. Speech Signal Process..

[27]  A. Murat Tekalp,et al.  Edge-adaptive Kalman filtering for image restoration with ringing suppression , 1989, IEEE Trans. Acoust. Speech Signal Process..

[28]  P W Doherty,et al.  Interactive visual optimization of SPECT prereconstruction filtering. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[29]  H. Akaike A new look at the statistical model identification , 1974 .

[30]  JOHN w. WOODS,et al.  Kalman filtering in two dimensions , 1977, IEEE Trans. Inf. Theory.

[31]  B. C. Penney,et al.  Two-dimensional filtering of SPECT images using the Metz and Wiener filters. , 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[32]  T R Miller,et al.  A practical method of image enhancement by interactive digital filtering. , 1985, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[33]  S Webb,et al.  Deconvolution of emission tomographic data: a clinical evaluation. , 1988, The British journal of radiology.

[34]  S Webb,et al.  A comparison of deconvolution and windowed subtraction techniques for scatter compensation in SPECT. , 1988, IEEE transactions on medical imaging.

[35]  Michael A. King,et al.  An investigation of the stationarity of the 3D modulation transfer function of SPECT , 1989 .

[36]  Junji Maeda,et al.  Digital Restoration of Scintigraphic Images by a Two-Step Procedure , 1987, IEEE Transactions on Medical Imaging.

[37]  B. C. Penney,et al.  A Wiener filter for nuclear medicine images. , 1983, Medical physics.

[38]  P. Msaki,et al.  Subtraction of Compton-scattered photons in single-photon emission computerized tomography. , 1984, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[39]  R.E. Kearney,et al.  Experimental determination of CT point spread function , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[40]  S Webb,et al.  Constrained deconvolution of SPECT liver tomograms by direct digital image restoration. , 1985, Medical physics.

[41]  A K Boardman,et al.  Constrained optimisation and its application to scintigraphy. , 1979, Physics in medicine and biology.

[42]  R. Jaszczak,et al.  SPECT: Single Photon Emission Computed Tomography , 1980 .

[43]  Lee-Tzuu Chang,et al.  A Method for Attenuation Correction in Radionuclide Computed Tomography , 1978, IEEE Transactions on Nuclear Science.

[44]  M A King,et al.  Activity quantitation in SPECT: a study of prereconstruction Metz filtering and use of the scatter degradation factor. , 1991, Medical physics.

[45]  T R Miller,et al.  Fast count-dependent digital filtering of nuclear medicine images: concise communication. , 1983, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[46]  R M Rangayyan,et al.  Restoration of gamma camera-based nuclear medicine images. , 1989, IEEE transactions on medical imaging.