Oxidation of organophosphorus pesticides for the sensitive detection by a cholinesterase-based biosensor.

A potentiometric flow injection-type biosensor developed in our laboratory was used for the determination of organophosphorus pesticides (OPs). The principle of the biosensor is that the degree of inhibition of a sensor enzyme by an OP is dependent on the concentration of the pesticide. The sensor system consisted of a reactor with acetylcholinesterase (AChE) immobilized on a controlled pore glass and a detector with a tubular H(+)-selective membrane electrode. In order to examine the possibility of enhancing the sensitivity of the sensor by converting OPs to oxidized forms (stronger inhibitors), a comparison of the degree of enzyme inhibition by OPs at 10(-6) M before and after their oxidation was made. All of the ten pesticides tested exhibited greater inhibitory power toward the sensor enzyme following oxidation. All of the oxidized pesticides at 10(-6) M inhibited the sensor enzyme to a considerable degree, demonstrating the utility of the developed method for the class-specific determination of OPs. A calibration curve for diazinon, over the concentration range of 10(-11)-10(-4) M, was obtained. The lower detection limit was 2 x 10(-10) M. Treatment of the inhibited enzyme with pyridine-2-aldoxime restored the enzyme to near full activity, allowing repeated use of the sensor.

[1]  P C Pandey,et al.  Studies on acetylcholine sensor and its analytical application based on the inhibition of cholinesterase. , 1990, Biosensors & bioelectronics.

[2]  Andrea Cagnini,et al.  DISPOSABLE RUTHENIZED SCREEN-PRINTED BIOSENSORS FOR PESTICIDES MONITORING , 1995 .

[3]  Maria Pia Sammartino,et al.  Organophosphorus pesticide (Paraoxon) analysis using solid state sensors , 1996 .

[4]  Giuseppe Palleschi,et al.  Determination of organophosphorus insecticides with a choline electrochemical biosensor , 1992 .

[5]  Hye-Sung Lee,et al.  Flow Injection Biosensor for the Detection of Anti-Cholinesterases , 1998 .

[6]  C. Tran-Minh,et al.  Determination of organophosphorous and carbamate insecticides by flow injection analysis. , 1992, Analytical biochemistry.

[7]  E H Hansen Flow injection analysis: A complementary or alternative concept to biosensors. , 1994, Talanta.

[8]  Salvador Alegret,et al.  Determination of organophosphorus and carbamate pesticides using a biosensor based on a polishable, 7,7,8,8-tetracyanoquino-dimethane-modified, graphite—epoxy biocomposite , 1997 .

[9]  C Cremisini,et al.  Anticholinesterase activity measurement by a choline biosensor: application in water analysis. , 1993, Biosensors & bioelectronics.

[10]  T. Noguer,et al.  Enzyme sensors for the detection of pesticides , 1993 .

[11]  H. Lee,et al.  A convenient method for oxidation of organophosphorus pesticides in organic solvents. , 2000, Environmental research.

[12]  G. Cha,et al.  Fabrication of butyrylcholinesterase sensor using polyurethane-based ion-selective membranes. , 1999, Biosensors & bioelectronics.

[13]  M. Mascini,et al.  Sensitive detection of pesticides using amperometric sensors based on cobalt phthalocyanine-modified composite electrodes and immobilized cholinesterases. , 1992, Biosensors & bioelectronics.

[14]  Marek Trojanowicz,et al.  Determination of pesticides using electrochemical biosensors , 1996 .

[15]  Petr Skládal,et al.  Detection of organophosphate and carbamate pesticides using disposable biosensors based on chemically modified electrodes and immobilized cholinesterase , 1992 .

[16]  M. Mascini,et al.  Determination of anticholinesterase pesticides in real samples using a disposable biosensor , 1997 .

[17]  Mark E. Meyerhoff,et al.  An ion-selective electrode/flow-injection analysis experiment: determination of potassium in serum , 1983 .

[18]  Marco Mascini,et al.  Uses of immobilized biological compounds , 1993 .