Post-Procedure Evaluation of Microwave Ablations of Hepatocellular Carcinomas Using Electrode Displacement Elastography.

Microwave ablation has been used clinically as an alternative to surgical resection. However, lack of real-time imaging to assess treated regions may compromise treatment outcomes. We previously introduced electrode displacement elastography (EDE) for strain imaging and verified its feasibility in vivo on porcine animal models. In this study, we evaluated EDE on 44 patients diagnosed with hepatocellular carcinoma, treated using microwave ablation. The ablated region was identified on EDE images for 40 of the 44 patients. Ablation areas averaged 13.38 ± 4.99 cm2 on EDE, compared with 7.61 ± 3.21 cm2 on B-mode imaging. Contrast and contrast-to-noise ratios obtained with EDE were 232% and 98%, respectively, significantly higher than values measured on B-mode images (p < 0.001). This study indicates that EDE is feasible in patients and provides improved visualization of the ablation zone compared with B-mode ultrasound.

[1]  Stephen J Hsu,et al.  In vivo guidance and assessment of liver radio-frequency ablation with acoustic radiation force elastography. , 2008, Ultrasound in medicine & biology.

[2]  Tomy Varghese,et al.  Three-Dimensional Sheaf of Ultrasound Planes Reconstruction (SOUPR) of Ablated Volumes , 2014, IEEE Transactions on Medical Imaging.

[3]  Tomy Varghese,et al.  Elastographic Imaging of Thermal Lesions in Liver In-Vivo Using Diaphragmatic Stimuli , 2004, Ultrasonic imaging.

[4]  T. Krouskop,et al.  Elastographic characterization of HIFU-induced lesions in canine livers. , 1999, Ultrasound in medicine & biology.

[5]  C. S. Spalding,et al.  In vivo real-time freehand palpation imaging. , 2003, Ultrasound in medicine & biology.

[6]  Christopher L Brace,et al.  Microwave Ablation: Comparison of Simultaneous and Sequential Activation of Multiple Antennas in Liver Model Systems. , 2016, Radiology.

[7]  T. Varghese,et al.  In Vivo Classification of Breast Masses Using Features Derived From Axial-Strain and Axial-Shear Images , 2012, Ultrasonic imaging.

[8]  Meghan G. Lubner,et al.  Microwave versus Radiofrequency Ablation Treatment for Hepatocellular Carcinoma: A Comparison of Efficacy at a Single Center. , 2016, Journal of vascular and interventional radiology : JVIR.

[9]  Tomy Varghese,et al.  Monitoring stiffness changes in lesions after radiofrequency ablation at different temperatures and durations of ablation. , 2005, Ultrasound in medicine & biology.

[10]  Carlos Cuevas,et al.  Ultrasound‐Based Elastography: A Novel Approach to Assess Radio Frequency Ablation of Liver Masses Performed With Expandable Ablation Probes , 2008, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[11]  T. Varghese Quasi-Static Ultrasound Elastography. , 2009, Ultrasound clinics.

[12]  M Pernot,et al.  Real time shear waves elastography monitoring of thermal ablation: in vivo evaluation in pig livers. , 2014, The Journal of surgical research.

[13]  M Takahashi,et al.  Treatment of hepatocellular carcinoma: value of percutaneous microwave coagulation. , 1995, AJR. American journal of roentgenology.

[14]  A. Covey,et al.  Recent progress in understanding, diagnosing, and treating hepatocellular carcinoma , 2012, CA: a cancer journal for clinicians.

[15]  M. Kudo,et al.  Review of dynamic contrast-enhanced ultrasound guidance in ablation therapy for hepatocellular carcinoma. , 2011, World journal of gastroenterology.

[16]  Tomy Varghese,et al.  Three-dimensional electrode displacement elastography using the Siemens C7F2 fourSight four-dimensional ultrasound transducer. , 2008, Ultrasound in medicine & biology.

[17]  Tomy Varghese,et al.  Visualizing ex vivo radiofrequency and microwave ablation zones using electrode vibration elastography. , 2012, Medical physics.

[18]  Chunlan Yang,et al.  A survey of ultrasound elastography approaches to percutaneous ablation monitoring , 2014, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[19]  T. Varghese,et al.  Improving thermal ablation delineation with electrode vibration elastography using a bidirectional wave propagation assumption , 2012, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[20]  Christopher L Brace,et al.  Microwave Ablation of Hepatic Malignancy , 2013, Seminars in Interventional Radiology.

[21]  Kenneth Hoyt,et al.  Real-time sonoelastography of hepatic thermal lesions in a swine model. , 2008, Medical physics.

[22]  A. Jacobs,et al.  Radiofrequency Ablation for Liver Cancer. , 2015, Radiologic technology.

[23]  Xiao-Yan Xie,et al.  Percutaneous microwave and radiofrequency ablation for hepatocellular carcinoma: a retrospective comparative study , 2005, Journal of Gastroenterology.

[24]  P M Paprottka,et al.  Image fusion in the management of thermal tumor ablation of the liver. , 2012, Clinical hemorheology and microcirculation.

[25]  Junji Konishi,et al.  Small hepatocellular carcinoma: comparison of radio-frequency ablation and percutaneous microwave coagulation therapy. , 2002, Radiology.

[26]  K. Parker,et al.  Two-dimensional sonoelastographic shear velocity imaging. , 2008, Ultrasound in medicine & biology.

[27]  Tomy Varghese,et al.  Radio-frequency ablation electrode displacement elastography: a phantom study. , 2008, Medical physics.

[28]  D. Sindram,et al.  Operative Microwave Ablation for Hepatocellular Carcinoma: Complications, Recurrence, and Long-Term Outcomes , 2013, Journal of Gastrointestinal Surgery.

[29]  Tomy Varghese,et al.  Multilevel hybrid 2D strain imaging algorithm for ultrasound sector/phased arrays. , 2009, Medical physics.

[30]  Pengfei Song,et al.  Bias observed in time-of-flight shear wave speed measurements using radiation force of a focused ultrasound beam. , 2011, Ultrasound in medicine & biology.

[31]  T. Varghese,et al.  Elastographic measurement of the area and volume of thermal lesions resulting from radiofrequency ablation: pathologic correlation. , 2003, AJR. American journal of roentgenology.

[32]  Ryosuke Tateishi,et al.  nature publishing group ORIGINAL CONTRIBUTIONS 569 CME Radiofrequency Ablation for Hepatocellular Carcinoma: 10-Year Outcome and Prognostic Factors LIVER , 2022 .

[33]  T. Varghese,et al.  Impact of Gas Bubbles Generated During Interstitial Ablation on Elastographic Depiction of In Vitro Thermal Lesions , 2004, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[34]  Tomy Varghese,et al.  Characterizing the compression-dependent viscoelastic properties of human hepatic pathologies using dynamic compression testing , 2012, Physics in medicine and biology.

[35]  S. Emelianov,et al.  Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics. , 1998, Ultrasound in medicine & biology.

[36]  M. Daniels,et al.  Investigation of temperature-dependent viscoelastic properties of thermal lesions in ex vivo animal liver tissue. , 2009, Journal of biomechanics.

[37]  Kathryn R Nightingale,et al.  Combined Ultrasonic Thermal Ablation with Interleaved ARFI Image Monitoring Using a Single Diagnostic Curvilinear Array: A Feasibility Study , 2011, Ultrasonic imaging.

[38]  K. Nightingale,et al.  DEPOSITION ON SHEAR WAVE SPEED RECONSTRUCTION IN HUMAN LIVER , 2022 .

[39]  T. Varghese,et al.  Two-dimensional multi-level strain estimation for discontinuous tissue , 2007, Physics in medicine and biology.

[40]  J. Hinshaw,et al.  Percutaneous microwave ablation of hepatocellular carcinoma with a gas-cooled system: initial clinical results with 107 tumors. , 2015, Journal of vascular and interventional radiology : JVIR.

[41]  R. Lencioni,et al.  Local-regional treatment of hepatocellular carcinoma. , 2012, Radiology.

[42]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[43]  B. Wilson,et al.  Hepatic interstitial laser photocoagulation: demonstration and possible clinical importance of intravascular gas. , 1994, Radiology.

[44]  Tomy Varghese,et al.  Radiofrequency electrode vibration-induced shear wave imaging for tissue modulus estimation: a simulation study. , 2010, The Journal of the Acoustical Society of America.

[45]  Andrew H. Gee,et al.  A quality-guided displacement tracking algorithm for ultrasonic elasticity imaging , 2009, Medical Image Anal..

[46]  D. Sindram,et al.  Hepatic tumor ablation. , 2010, The Surgical clinics of North America.

[47]  T Varghese,et al.  Electrode displacement strain imaging of thermally-ablated liver tissue in an in vivo animal model. , 2010, Medical physics.

[48]  S. Wells,et al.  Liver Ablation: Best Practice. , 2015, Radiologic clinics of North America.

[49]  J Ophir,et al.  An analysis of elastographic contrast-to-noise ratio. , 1998, Ultrasound in medicine & biology.

[50]  T. Varghese,et al.  Elastographic imaging of thermal lesions in the liver in vivo following radiofrequency ablation: preliminary results. , 2002, Ultrasound in medicine & biology.

[51]  Tomy Varghese,et al.  Ultrasonic Imaging of Myocardial Strain Using Cardiac Elastography , 2003, Ultrasonic imaging.

[52]  G. Poggi,et al.  Microwave ablation of hepatocellular carcinoma. , 2015, World journal of hepatology.

[53]  T. Varghese,et al.  Ultrasound-based relative elastic modulus imaging for visualizing thermal ablation zones in a porcine model , 2010, Physics in medicine and biology.

[54]  G. Trahey,et al.  On the feasibility of remote palpation using acoustic radiation force. , 2001, The Journal of the Acoustical Society of America.

[55]  M. Kuang,et al.  Efficacy of microwave versus radiofrequency ablation for treatment of small hepatocellular carcinoma: experimental and clinical studies , 2012, European Radiology.