Fracture of the polyethylene tibial post in the posterior-stabilized total knee prosthesis: arthrographic and CT arthrographic diagnosis
暂无分享,去创建一个
[1] D. Naudie,et al. The role of isolated polyethylene exchange in total knee arthroplasty , 2017, EFORT open reviews.
[2] T. Tomita,et al. Nontraumatic tibial polyethylene insert cone fracture in mobile-bearing posterior-stabilized total knee arthroplasty , 2016, Arthroplasty today.
[3] M. Capella,et al. Mobile bearing and fixed bearing total knee arthroplasty. , 2016, Annals of translational medicine.
[4] H. Potter,et al. MRI of Polyethylene Tibial Inserts in Total Knee Arthroplasty: Normal and Abnormal Appearances. , 2016, AJR. American journal of roentgenology.
[5] R. Raj,et al. Fracture of the polyethylene tibial post in a posterior stabilized knee prosthesis: A case report and review of literature. , 2015, Journal of orthopaedics.
[6] A. Colosimo,et al. Polyethylene Tibial Post Fracture in a Posterior Stabilized (Genesis II) Total Knee Arthroplasty , 2015, Journal of Knee Surgery Reports.
[7] Jan Fritz,et al. MR Imaging of Knee Arthroplasty Implants. , 2015, Radiographics : a review publication of the Radiological Society of North America, Inc.
[8] G. Scuderi**,et al. Symptomatic flexion instability in posterior stabilized primary total knee arthroplasty. , 2014, Orthopedics.
[9] Hyojeong Mulcahy,et al. Current concepts in knee replacement: features and imaging assessment. , 2013, AJR. American journal of roentgenology.
[10] Tomoyuki Saito,et al. Mid- term results of stryker® scorpio plus mobile bearing total knee arthroplasty , 2012, Sports Medicine, Arthroscopy, Rehabilitation, Therapy & Technology.
[11] J. Aubaniac,et al. The outcome of rotating-platform total knee arthroplasty with cement at a minimum of ten years of follow-up. , 2012, The Journal of bone and joint surgery. American volume.
[12] P. Lachiewicz. How to Treat A Tibial Post Fracture in Total Knee Arthroplasty? , 2011, Clinical orthopaedics and related research.
[13] J. Luchs,et al. Catastrophic polyethylene failure diagnosed with magnetic resonance imaging in a painful total knee arthroplasty. , 2011, Journal of Arthroplasty.
[14] C. Colwell,et al. Isolated Tibial Polyethylene Insert Exchange Outcomes After Total Knee Arthroplasty , 2010, Clinical orthopaedics and related research.
[15] Hong-chul Lim,et al. Fracture of a Polyethylene Tibial Post in a Scorpio Posterior-Stabilized Knee Prosthesis , 2009, Clinics in orthopedic surgery.
[16] T. Johnson,et al. Anterior tibial post impingement in a posterior stabilized total knee arthroplasty , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[17] Tain‐Hsiung Chen,et al. Fracture of the polyethylene tibial post in a NexGen posterior-stabilized knee prosthesis. , 2004, The Journal of arthroplasty.
[18] David R Mauerhan,et al. Fracture of the polyethylene tibial post in a posterior cruciate-substituting total knee arthroplasty mimicking patellar clunk syndrome: a report of 5 cases. , 2003, The Journal of arthroplasty.