Design optimisation of a TOF-based collimated camera prototype for online hadrontherapy monitoring

Hadrontherapy is an innovative radiation therapy modality for which one of the main key advantages is the target conformality allowed by the physical properties of ion species. However, in order to maximise the exploitation of its potentialities, online monitoring is required in order to assert the treatment quality, namely monitoring devices relying on the detection of secondary radiations. Herein is presented a method based on Monte Carlo simulations to optimise a multi-slit collimated camera employing time-of-flight selection of prompt-gamma rays to be used in a clinical scenario. In addition, an analytical tool is developed based on the Monte Carlo data to predict the expected precision for a given geometrical configuration. Such a method follows the clinical workflow requirements to simultaneously have a solution that is relatively accurate and fast. Two different camera designs are proposed, considering different endpoints based on the trade-off between camera detection efficiency and spatial resolution to be used in a proton therapy treatment with active dose delivery and assuming a homogeneous target.

[1]  D Dauvergne,et al.  Assessment and improvements of Geant4 hadronic models in the context of prompt-gamma hadrontherapy monitoring , 2014, Physics in medicine and biology.

[2]  P. Busca,et al.  Prompt gamma imaging with a slit camera for real-time range control in proton therapy , 2012, 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC).

[3]  D Dauvergne,et al.  Design Guidelines for a Double Scattering Compton Camera for Prompt-$\gamma$ Imaging During Ion Beam Therapy: A Monte Carlo Simulation Study , 2011, IEEE Transactions on Nuclear Science.

[4]  A. Lechner,et al.  Validation of recent Geant4 physics models for application in carbon ion therapy , 2010 .

[5]  D Robertson,et al.  Optimizing a three-stage Compton camera for measuring prompt gamma rays emitted during proton radiotherapy , 2010, Physics in medicine and biology.

[6]  Sam Beddar,et al.  Material efficiency studies for a Compton camera designed to measure characteristic prompt gamma rays emitted during proton beam radiotherapy , 2011, Physics in medicine and biology.

[7]  Antony Lomax,et al.  In vivo proton range verification: a review , 2013, Physics in medicine and biology.

[8]  L Grevillot,et al.  A Monte Carlo pencil beam scanning model for proton treatment plan simulation using GATE/GEANT4 , 2011, Physics in medicine and biology.

[9]  M. Bajard,et al.  Monte Carlo Simulations of Prompt-Gamma Emission During Carbon Ion Irradiation , 2009, IEEE Transactions on Nuclear Science.

[10]  Chan Hyeong Kim,et al.  Prompt gamma measurements for locating the dose falloff region in the proton therapy , 2006 .

[11]  G Ciangaru,et al.  Prompt gamma-ray emission from biological tissues during proton irradiation: a preliminary study , 2009, Physics in medicine and biology.

[12]  Chan Hyeong Kim,et al.  Development of array-type prompt gamma measurement system for in vivo range verification in proton therapy. , 2012, Medical physics.

[13]  H. Paganetti,et al.  Physics Settings for Using the Geant4 Toolkit in Proton Therapy , 2008, IEEE Transactions on Nuclear Science.

[14]  A J Lomax,et al.  Treatment planning optimisation in proton therapy. , 2013, The British journal of radiology.

[15]  Katia Parodi,et al.  Time-of-flight neutron rejection to improve prompt gamma imaging for proton range verification: a simulation study , 2012, Physics in medicine and biology.

[16]  D Sarrut,et al.  Machine learning-based patient specific prompt-gamma dose monitoring in proton therapy , 2013, Physics in medicine and biology.

[17]  K. Amako,et al.  Comparison of Geant4 electromagnetic physics models against the NIST reference data , 2005, IEEE Transactions on Nuclear Science.

[18]  Harald Paganetti,et al.  Relative biological effectiveness (RBE) values for proton beam therapy. , 2002, International journal of radiation oncology, biology, physics.

[19]  Joao Seco,et al.  Simulation of prompt gamma-ray emission during proton radiotherapy , 2012, Physics in medicine and biology.

[20]  H. Paganetti Range uncertainties in proton therapy and the role of Monte Carlo simulations , 2012, Physics in medicine and biology.

[21]  W. Schlegel,et al.  Accuracy of a commercial optical 3D surface imaging system for realignment of patients for radiotherapy of the thorax , 2007, Physics in medicine and biology.

[22]  Denis Dauvergne,et al.  Real-time monitoring of the Bragg-peak position in ion therapy by means of single photon detection , 2010, Radiation and environmental biophysics.

[23]  L Grevillot,et al.  GATE as a GEANT4-based Monte Carlo platform for the evaluation of proton pencil beam scanning treatment plans , 2012, Physics in medicine and biology.

[24]  M. Bajard,et al.  Monitoring the Bragg peak location of 73 MeV/u carbon ions by means of prompt γ-ray measurements , 2008, 0809.0185.

[25]  G Janssens,et al.  Real-time proton beam range monitoring by means of prompt-gamma detection with a collimated camera , 2014, Physics in medicine and biology.

[26]  P. Rousseeuw Silhouettes: a graphical aid to the interpretation and validation of cluster analysis , 1987 .

[27]  G. W. Phillips Gamma-ray imaging with Compton cameras , 1995 .

[28]  Freek Beekman,et al.  Real-time prompt gamma monitoring in spot-scanning proton therapy using imaging through a knife-edge-shaped slit , 2012, Physics in medicine and biology.

[29]  Dieter Schardt,et al.  Heavy-ion tumor therapy: Physical and radiobiological benefits , 2010 .

[30]  A. Lomax,et al.  Is it necessary to plan with safety margins for actively scanned proton therapy? , 2011, Physics in medicine and biology.

[31]  F. Rademakers,et al.  ROOT — An object oriented data analysis framework , 1997 .

[32]  Sam Beddar,et al.  Evaluation of a stochastic reconstruction algorithm for use in Compton camera imaging and beam range verification from secondary gamma emission during proton therapy , 2012, Physics in medicine and biology.