Accuracy of Percutaneous CT-Guided Spine Biopsy and Determinants of Biopsy Success

Purpose: The purpose of this study was to investigate the accuracy of CT-guided spine biopsy as well as the factors that may influence its success. Methods and Materials: A total of 170 CT-guided biopsies performed on 156 patients with vertebral lesions were retrospectively analyzed. The accuracy of the biopsies was evaluated by comparing the final diagnosis with the biopsy results for patients who underwent surgery or with six-month clinical and radiological follow-up findings for patients who did not have surgery. The radiological features of each lesion, the features of the needles used, the needle approach, the pathology results, and the patient demographic data were statistically analyzed with Fisher exact test and ANOVA for their influence on the success of the biopsy. Results: The total success rate of percutaneous vertebral needle biopsies performed with CT guidance was 80 per cent (136/170). Age (p = 0.39), gender (p = 0.43), lesion location (p = 0.2), radiographic appearance (p = 0.8), needle type (p = 0.6), and approach (p = 0.1) had no effect on the adequacy of the obtained material or the success of the biopsy. There was a relationship between lesion histopathology and the rate of adequacy or success (p < 0.001). There was no relationship between the needle approach or the radiographic appearance of the lesion and the length of the specimen (p = 0.1). There were no major complications requiring treatment. Conclusion: The success rate of CT-guided percutaneous needle biopsy was close to that found in previous studies in the literature and independent of most patient parameters. Its complication rates are acceptable in experienced hands.

[1]  Scott D Nelson,et al.  Revisiting CT-guided percutaneous core needle biopsy of musculoskeletal lesions: contributors to biopsy success. , 2011, AJR. American journal of roentgenology.

[2]  J. S. Biermann,et al.  Accuracy of CT-guided percutaneous core needle biopsy for assessment of pediatric musculoskeletal lesions , 2011, Pediatric Radiology.

[3]  I. Pak,et al.  Factors in sample volume and quality of CT-guided vertebral biopsy: location and needle trajectory. , 2010, Turkish neurosurgery.

[4]  Masahiro Yoshida,et al.  CT-guided needle biopsy for musculoskeletal lesions , 2010, Archives of Orthopaedic and Trauma Surgery.

[5]  M. Hochman,et al.  Bone and soft-tissue lesions: what factors affect diagnostic yield of image-guided core-needle biopsy? , 2008, Radiology.

[6]  M. Alberghini,et al.  Percutaneous CT-guided biopsy of the spine: results of 430 biopsies , 2008, European Spine Journal.

[7]  Charles Smith,et al.  Image-guided percutaneous biopsy of musculoskeletal lesions in children , 2007, Pediatric Radiology.

[8]  H. Sucu,et al.  Percutaneous computed-tomography-guided biopsy of the spine: 229 procedures. , 2006, Joint, bone, spine : revue du rhumatisme.

[9]  G. Krol,et al.  Percutaneous CT-guided biopsy of osseous lesion of the spine in patients with known or suspected malignancy. , 2004, AJNR. American journal of neuroradiology.

[10]  E. Transfeldt,et al.  Diagnostic Value of Open and Needle Biopsies in Tumors of the Sacrum , 2003, Spine.

[11]  B. Shmookler,et al.  Diagnosis of primary bone tumors with image-guided percutaneous biopsy: experience with 110 tumors. , 2002, Radiology.

[12]  M. Gebhardt,et al.  Accuracy of CT-guided biopsies in 359 patients with musculoskeletal lesions , 2002, Skeletal Radiology.

[13]  G. Geremia,et al.  Percutaneous needle biopsy of the spine. , 2000, Neuroimaging clinics of North America.

[14]  J. Garcés,et al.  Lateral access for CT-guided percutaneous biopsy of the lumbar spine. , 2000, AJR. American journal of roentgenology.

[15]  L. Seeger,et al.  Primary musculoskeletal neoplasms: effectiveness of core-needle biopsy. , 1999, Radiology.

[16]  J. Fischgrund,et al.  Computed Tomography‐Guided Biopsy of the Spine: A Review of 103 Patients , 1998, Spine.

[17]  C. Reading,et al.  Percutaneous needle biopsy , 1997, Abdominal Imaging.

[18]  F. Magerl,et al.  The Value of Percutaneous Transpedicular Vertebral Bone Biopsies for Histologic Examination: Results of an Experimental Histopathologic Study Comparing Two Biopsy Needles , 1996, Spine.

[19]  L. Howell,et al.  Fine‐needle aspiration cytology of sarcoma: Retrospective review of diagnostic utility and specificity , 1996, Diagnostic cytopathology.

[20]  H. Mankin,et al.  The Hazards of the Biopsy, Revisited. For the Members of the Musculoskeletal Tumor Society* , 1996, The Journal of bone and joint surgery. American volume.

[21]  A. Yasko,et al.  Core needle biopsy and fine-needle aspiration in the diagnosis of bone and soft-tissue lesions. , 1995, Hematology/oncology clinics of North America.

[22]  D. Renfrew,et al.  CT-guided percutaneous transpedicular biopsy of the spine. , 1991, Radiology.

[23]  B. Ghelman,et al.  Percutaneous Computed-Tomography-Guided Biopsy of the Thoracic and Lumbar Spine , 1991, Spine.

[24]  M. Revel,et al.  CT-guided vertebral biopsy. A report of 89 cases. , 1991, Journal of neuroradiology. Journal de neuroradiologie.

[25]  L. Wiltse,et al.  Anatomic Analysis of Pedicle Cortical and Cancellous Diameter as Related to Screw Size , 1989, Spine.

[26]  A G Patwardhan,et al.  Analysis of the Morphometric Characteristics of the Thoracic and Lumbar Pedicles , 1987, Spine.

[27]  L. Wold,et al.  Imaging-assisted percutaneous biopsy of the thoracic spine. , 1986, Mayo Clinic proceedings.

[28]  J. Laredo,et al.  Thoracic spine: percutaneous trephine biopsy. , 1986, Radiology.

[29]  B. Glasgow,et al.  Fine-needle aspiration of primary soft-tissue lesions. , 1986, Archives of pathology & laboratory medicine.

[30]  J. Oosterhuis,et al.  Biopsy of bone tumours , 1985, Journal of surgical oncology.

[31]  D. Stoker,et al.  Percutaneous vertebral biopsy: a review of 135 cases. , 1985, Clinical radiology.

[32]  A. Ayala,et al.  Primary bone tumors: percutaneous needle biopsy. Radiologic-pathologic study of 222 biopsies. , 1983, Radiology.

[33]  R. Mulholland,et al.  Closed vertebral biopsy. , 1983, The Journal of bone and joint surgery. British volume.