Monitoring of polyethylene wear in nonmetal-backed acetubular cups by digitized anteroposterior pelvic radiography

The aim of this study was to assess polyethylene wear in a total hip prosthesis by digitized radiography of the whole pelvis in the anteroposterior (AP) plane. The three-dimensional (3-D) pose of the nonmetal-backed acetubular cup, materialized by its metal ring and the femoral head made of metal or ceramic, was estimated using iterative algebraic algorithms with inner bias correction and bootstrapping for variance reduction. Points of interest were obtained by maximizing the correlation between sampled density profiles and 3-D geometric models degraded by the modulation transfer function (MTF) of the radiographic system and the film scanner. The error in the maximal correlation estimate were inferred from noise power spectra (NPS) and allowed the calculation of the point covariance matrix. Both NPS and MTF were modeled for each stage and estimated using least-square fitting of the overall NPS model to the autospectral density function calculated in stationary regions. Comparison of the radiographic time series was made possible by the high accuracy level and 3-D matching from the cup orientation. The feasibility of the full 3-D measurement, the assumption of negligible lateral wear and its influence on AP wear are discussed on simulated and real radiographic data.

[1]  William H. Press,et al.  Numerical recipes , 1990 .

[2]  J. Bendat,et al.  Random Data: Analysis and Measurement Procedures , 1987 .

[3]  James Shih-Shyn Wu,et al.  Measurement of polyethylene wear - a new three-dimensional methodology , 2002, Comput. Methods Programs Biomed..

[4]  Wojciech Chojnacki,et al.  Rationalising the Renormalisation Method of Kanatani , 2001, Journal of Mathematical Imaging and Vision.

[5]  Peter Meer,et al.  Unbiased Estimation of Ellipses by Bootstrapping , 1996, IEEE Trans. Pattern Anal. Mach. Intell..

[6]  Rachid Deriche,et al.  Using Canny's criteria to derive a recursively implemented optimal edge detector , 1987, International Journal of Computer Vision.

[7]  Alan L. Yuille,et al.  Feature extraction from faces using deformable templates , 2004, International Journal of Computer Vision.

[8]  Effect of Scattered X Rays on Image Signal of Radiograph , 2000 .

[9]  Josef Kittler,et al.  A survey of the hough transform , 1988, Comput. Vis. Graph. Image Process..

[10]  Kenichi Kanatani,et al.  Statistical Bias of Conic Fitting and Renormalization , 1994, IEEE Trans. Pattern Anal. Mach. Intell..

[11]  Michael Sandborg,et al.  Optimization of chest and lumbar spine radiography by Monte Carlo modeling of the patient and imaging system , 1999, Medical Imaging.

[12]  R B Bourne,et al.  Measurement of polyethylene wear in metal-backed acetabular cups. I. Three-dimensional technique. , 1995, Clinical orthopaedics and related research.

[13]  A Fenster,et al.  A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems. , 1994, Medical physics.

[14]  Ian A. Cunningham Linear-systems modeling of parallel cascaded stochastic processes: the NPS of radiographic screens with reabsorption of characteristic x-radiation , 1998, Medical Imaging.

[15]  R B Bourne,et al.  Measurement of polyethylene wear in metal-backed acetabular cups. II. Clinical application. , 1995, Clinical orthopaedics and related research.

[16]  Rodney Shaw,et al.  Signal-to-noise optimization of medical imaging systems , 1999 .

[17]  Zhengyou Zhang,et al.  Parameter estimation techniques: a tutorial with application to conic fitting , 1997, Image Vis. Comput..

[18]  B. Morrey,et al.  Effect of femoral head size on wear of the polyethylene acetabular component. , 1990, The Journal of bone and joint surgery. American volume.

[19]  Aaron Fenster,et al.  Visual impact of the nonzero spatial frequency quantum sink , 1994, Medical Imaging.

[20]  Robert M. Haralick,et al.  An Integrated Linear Technique for Pose Estimation from Different Geometric Features , 1999, Int. J. Pattern Recognit. Artif. Intell..

[21]  C. Engh,et al.  Two-dimensional versus three-dimensional radiographic measurements of polyethylene wear. , 1999, Clinical orthopaedics and related research.