Localized echo‐volume imaging methods for functional MRI

To perform true three‐dimensional activation experiments in the human brain, dedicated localized echo‐volume imaging (L‐EVI) methods were developed. Three‐dimensional acquisition allows generation of activation maps with minimal vascular enhancement related to inflow effects. The rapid acquisition of the L‐EVI (∼100 msec) reduces signal instabilities caused by motion, facilitating the detection of the small intensity changes expected with brain activation. Single‐shot L‐EVI was performed on normal volunteers at 1.5 T, imaging a three‐dimensional predefined volume (240 × 45 × 45 mm3) in the superior portion of the brain with a spatial resolution of 3.75 × 5 × 5 mm3. Increased brain coverage was achieved with a multi‐volume imaging (three‐shot) version, which simultaneously achieved effective suppression of signals from cerebrospinal fluid. In addition, both asymmetric spin‐echo (ASE) and spin‐echo (SE) versions of the technique were used to detect blood oxygenation level dependent (BOLD) signal changes in the motor cortex with a finger‐tapping paradigm. Images obtained by the L‐EVI sequence were qualitatively comparable to standard multislice two‐dimensional echo‐planar images. Both ASE and SE functional MRI (fMRI) experiments showed consistent activation in the contralateral primary sensorimotor cortex. Furthermore, significant differences in location and magnitude of activation was observed between the two methods, confirming theoretical predictions.

[1]  J H Duyn,et al.  Inflow versus deoxyhemoglobin effects in bold functional MRI using gradient echoes at 1.5 T , 1994, NMR in biomedicine.

[2]  S. Ogawa,et al.  Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fields , 1990, Magnetic resonance in medicine.

[3]  D. Tank,et al.  Brain magnetic resonance imaging with contrast dependent on blood oxygenation. , 1990, Proceedings of the National Academy of Sciences of the United States of America.

[4]  Ravi S. Menon,et al.  Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model. , 1993, Biophysical journal.

[5]  R. Turner,et al.  Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[6]  S. Ogawa Brain magnetic resonance imaging with contrast-dependent oxygenation , 1990 .

[7]  R. S. Hinks,et al.  Time course EPI of human brain function during task activation , 1992, Magnetic resonance in medicine.

[8]  E. Haacke,et al.  Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at l.5T preliminary results , 1993, Magnetic resonance in medicine.

[9]  J. R. Baker,et al.  The intravascular contribution to fmri signal change: monte carlo modeling and diffusion‐weighted studies in vivo , 1995, Magnetic resonance in medicine.

[10]  Roger J. Ordidge,et al.  VOLUMAR IMAGING USING NMR SPIN ECHOES - ECHO-VOLUMAR IMAGING (EVI) AT 0.1-T , 1989 .

[11]  P. Mansfield Multi-planar image formation using NMR spin echoes , 1977 .

[12]  Karl J. Friston,et al.  Analysis of fMRI Time-Series Revisited—Again , 1995, NeuroImage.

[13]  F. Barrios,et al.  3‐dimensional functional imaging of human brain using echo‐shifted FLASH MRI , 1994, Magnetic resonance in medicine.

[14]  J. Pekar,et al.  Whole-brain functional mapping with isotropic MR imaging. , 1996, Radiology.

[15]  A. Song,et al.  Echo‐volume imaging , 1994, Magnetic resonance in medicine.

[16]  Michael Unser,et al.  Multiresolution image registration procedure using spline pyramids , 1993, Optics & Photonics.

[17]  D. Weinberger,et al.  Three-dimensional functional magnetic resonance imaging of human brain on a clinical 1.5-T scanner. , 1995, Proceedings of the National Academy of Sciences of the United States of America.

[18]  Michael Unser,et al.  Iterative multi-scale registration without landmarks , 1995, Proceedings., International Conference on Image Processing.

[19]  R. S. Hinks,et al.  Spin‐echo and gradient‐echo epi of human brain activation using bold contrast: A comparative study at 1.5 T , 1994, NMR in biomedicine.