Feasibility of combining MR perfusion, angiography, and 3He ventilation imaging for evaluation of lung function in a porcine model.

RATIONALE AND OBJECTIVE To assess the feasibility of combining magnetic resonance (MR) perfusion, angiography, and 3He ventilation imaging for the evaluation of lung function in a porcine model. MATERIALS AND METHODS Fourteen consecutive porcine models with externally delivered pulmonary emboli and/or airway occlusions were examined with MR perfusion, angiography, and 3He ventilation imaging. Ultrafast gradient-echo sequences were used for 3D perfusion and angiographic imaging, in conjunction with the use of contrast-agent injections. 2D multiple-section 3He imaging was performed subsequently via the inhalation of hyperpolarized 3He gas. The diagnostic accuracy of MR angiography for detecting pulmonary emboli was determined by two reviewers. The diagnostic confidence for different combinations of MR techniques was rated on the basis of a 5-point grading scale (5 = definite). RESULTS The sensitivity, specificity, and accuracy of MR angiography for detecting pulmonary emboli were approximately 85.7%, 90.5%, and 88.1%, respectively. The interobserver agreement was very strong (k = 0.82). There was a clear tendency for confidence to increase when first perfusion and then ventilation imaging were added to the angiographic image (Wilcoxon signed ranks test, P = 0.03). CONCLUSION The combination of the three methods of MR perfusion, angiography, and 3H ventilation imaging may provide complementary information on abnormal lung anatomy and function.

[1]  J Listerud,et al.  T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging. , 1999, European journal of radiology.

[2]  P. J. Drury,et al.  Acute pulmonary embolism: diagnosis with MR angiography. , 1999, Radiology.

[3]  P. Croisille,et al.  Prospective comparison of MR lung perfusion and lung scintigraphy , 1999, Journal of magnetic resonance imaging : JMRI.

[4]  J. Debatin,et al.  Contrast‐enhanced, ultrafast 3d pulmonary MR angiography in a single breath‐hold: Initial assessment of imaging performance , 1997, Journal of magnetic resonance imaging : JMRI.

[5]  J Listerud,et al.  Multi‐Slice, Breathhold Imaging of the Lung with Submillisecond Echo Times , 1995, Magnetic resonance in medicine.

[6]  H C Charles,et al.  Human lung air spaces: potential for MR imaging with hyperpolarized He-3. , 1996, Radiology.

[7]  T A Altes,et al.  Hyperpolarized 3He MR lung ventilation imaging in asthmatics: Preliminary findings , 2001, Journal of magnetic resonance imaging : JMRI.

[8]  M. Viallon,et al.  A combined 1H perfusion/3He ventilation NMR study in rat lungs , 1999, Magnetic resonance in medicine.

[9]  J R Brookeman,et al.  Lung air spaces: MR imaging evaluation with hyperpolarized 3He gas. , 1999, Radiology.

[10]  P. Aadahl,et al.  A closed-chest pulmonary artery occlusion/reperfusion model in the pig: detection of experimental pulmonary embolism with MR angiography and perfusion MR imaging. , 2000, Investigative radiology.

[11]  D. Šuput,et al.  Water proton NMR relaxation mechanisms in lung tissue , 1988, Magnetic resonance in medicine.

[12]  Cates,et al.  Relaxation of spins due to field inhomogeneities in gaseous samples at low magnetic fields and low pressures. , 1988, Physical review. A, General physics.

[13]  L. Hedlund,et al.  MR microscopy of lung airways with hyperpolarized 3He , 1998, Magnetic resonance in medicine.

[14]  R R Edelman,et al.  Pulmonary perfusion: Qualitative assessment with dynamic contrast‐enhanced MRI using ultra‐short TE and inversion recovery turbo FLASH , 1996, Magnetic resonance in medicine.

[15]  R R Edelman,et al.  Magnetic resonance T2* measurements of the normal human lung in vivo with ultra-short echo times. , 1999, Magnetic resonance imaging.

[16]  T L Chenevert,et al.  Diagnosis of pulmonary embolism with magnetic resonance angiography. , 1997, The New England journal of medicine.

[17]  R. Edelman,et al.  Pulmonary perfusion and angiography: evaluation with breath-hold enhanced three-dimensional fast imaging steady-state precession MR imaging with short TR and TE. , 1996, AJR. American journal of roentgenology.

[18]  A Potthast,et al.  Normal and abnormal pulmonary ventilation: visualization at hyperpolarized He-3 MR imaging. , 1996, Radiology.

[19]  N M Rofsky,et al.  Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: usefulness of a timing examination and MR power injector. , 1996, Radiology.

[20]  Punam K Saha,et al.  Co‐registration of acquired MR ventilation and perfusion images—Validation in a porcine model , 2003, Magnetic resonance in medicine.

[21]  D. Yablonskiy,et al.  Rapid imaging of hyperpolarized gas using EPI , 1999, Magnetic resonance in medicine.

[22]  L. Hedlund,et al.  MR Imaging with Hyperpolarized 3He Gas , 1995, Magnetic resonance in medicine.

[23]  T. Walker,et al.  Spin-exchange optical pumping of noble-gas nuclei , 1997 .

[24]  Jie Zheng,et al.  Combined MR proton lung perfusion/angiography and helium ventilation: Potential for detecting pulmonary emboli and ventilation defects , 2002, Magnetic resonance in medicine.

[25]  R R Edelman,et al.  Quantitative assessment of pulmonary perfusion with dynamic contrast‐enhanced MRI , 1999, Magnetic resonance in medicine.

[26]  D. Roberts,et al.  Operating characteristics of hyperpolarized 3He and arterial spin tagging in MR imaging of ventilation and perfusion in healthy subjects. , 2003, Academic radiology.

[27]  L. Hedlund,et al.  Measurements of hyperpolarized gas properties in the lung. part III: 3He T1 , 2001, Magnetic resonance in medicine.

[28]  K Sugimura,et al.  Oxygen-enhanced MR ventilation imaging of the lung: preliminary clinical experience in 25 subjects. , 2001, AJR. American journal of roentgenology.

[29]  D. Yablonskiy,et al.  MR imaging of diffusion of 3He gas in healthy and diseased lungs , 2000, Magnetic resonance in medicine.

[30]  G. Wang,et al.  Depiction of pulmonary emboli with spiral CT: optimization of display window settings in a porcine model. , 1997, Radiology.

[31]  Michael Bock,et al.  High‐resolution pulmonary arterio‐ and venography using multiple‐bolus multiphase 3D‐gd‐mRA , 1999, Journal of magnetic resonance imaging : JMRI.