Interpretation and Classification of Microvolt T Wave Alternans Tests

Interpretation of T Wave Alternans Tests. Measurement of microvolt‐level T wave alternans (TWA) during routine exercise stress testing now is possible as a result of sophisticated noise reduction techniques and analytic methods that have become commercially available. Even though this technology is new, the available data suggest that microvolt TWA is a potent predictor of arrhythmia risk in diverse disease states. As this technology becomes more widely available, physicians will be called upon to interpret microvolt TWA tracings. This review seeks to establish uniform standards for the clinical interpretation of microvolt TWA tracings.

[1]  R J Cohen,et al.  Predicting Sudden Cardiac Death From T Wave Alternans of the Surface Electrocardiogram: , 1996, Journal of cardiovascular electrophysiology.

[2]  N. el-Sherif,et al.  Repolarization alternans associated with alcoholism and hypomagnesemia. , 1984, The American journal of cardiology.

[3]  R J Cohen,et al.  T Wave Alternans During Exercise and Atrial Pacing in Humans , 1997, Journal of cardiovascular electrophysiology.

[4]  M. Yokoyama,et al.  Determinant of microvolt-level T-wave alternans in patients with dilated cardiomyopathy. , 1999, Journal of the American College of Cardiology.

[5]  M R Gold,et al.  A comparison of T-wave alternans, signal averaged electrocardiography and programmed ventricular stimulation for arrhythmia risk stratification. , 2000, Journal of the American College of Cardiology.

[6]  Takanori Ikeda,et al.  T-wave alternans as a predictor for sudden cardiac death after myocardial infarction. , 2002, The American journal of cardiology.

[7]  T. Ikeda,et al.  Combined assessment of T-wave alternans and late potentials used to predict arrhythmic events after myocardial infarction. A prospective study. , 2000, Journal of the American College of Cardiology.

[8]  R. Cohen,et al.  Alternating morphology of the QRST complex preceding sudden death. , 1992, The New England journal of medicine.

[9]  J. Ruskin,et al.  Electrical alternans and vulnerability to ventricular arrhythmias. , 1994, The New England journal of medicine.

[10]  A Malliani,et al.  Electrical alternation of the T-wave: clinical and experimental evidence of its relationship with the sympathetic nervous system and with the long Q-T syndrome. , 1975, American heart journal.

[11]  S. Hohnloser,et al.  Effect of metoprolol and d,l-sotalol on microvolt-level T-wave alternans. Results of a prospective, double-blind, randomized study. , 2001, Journal of the American College of Cardiology.

[12]  T. Ashley Long-term outcome in asymptomatic men with exercise-induced premature ventricular depolarizations. , 2001, Journal of insurance medicine.

[13]  R J Cohen,et al.  T Wave Alternans as a Predictor of Recurrent Ventricular Tachyarrhythmias in ICD Recipients: Prospective Comparison with Conventional Risk Markers , 1998, Journal of cardiovascular electrophysiology.

[14]  S. Hohnloser,et al.  Predictive value of T-wave alternans for arrhythmic events in patients with congestive heart failure , 2000, The Lancet.

[15]  J Hartikainen,et al.  Exercise-induced T-wave alternans as a marker of high risk in patients with hypertrophic cardiomyopathy. , 1997, Japanese circulation journal.

[16]  Z. Shimoni,et al.  Electrical alternans of giant U waves with multiple electrolyte deficits. , 1984, The American journal of cardiology.

[17]  T. Sano,et al.  Electrical alternans of TU wave in Romano-Ward syndrome. , 1976, British heart journal.

[18]  R J Cohen,et al.  Electrical alternans and cardiac electrical instability. , 1988, Circulation.

[19]  R J Cohen,et al.  Exercise recordings for the detection of T wave alternans. Promises and pitfalls. , 1996, Journal of electrocardiology.