Monitoring of blood glucose levels is of utmost importance due to the high incidence of diabetes in our society. There is a need for a non-invasive method that is cost-effective and highly accurate. We have utilized absorption signatures at 10 fixed wavelengths in the near-infrared region of optical radiation to predict glucose levels. We have recorded 64 spectra of laboratory samples having glucose, urea, analine, lactate, and ascorbate with concentrations of clinical relevance. Of which 54 were used to calibrate the models and the rest 10 sample spectra are used to test the prediction accuracy. PLSR models gave a root mean square error of prediction as 13.90 mg/dL. The prediction accuracy is further enhanced by implementing Machine Learning using neural network to 6.47 mg/dL. Neural network provides superior performance for the prediction of glucose concentration.

[1]  Yan Yu,et al.  An Accurate Noninvasive Blood Glucose Measurement System Using Portable Near-Infrared Spectrometer and Transfer Learning Framework , 2021, IEEE Sensors Journal.

[2]  Liu Yufei,et al.  Noninvasive and fast measurement of blood glucose in vivo by near infrared (NIR) spectroscopy. , 2017, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[3]  S. Wild,et al.  Global prevalence of diabetes: estimates for the year 2000 and projections for 2030. , 2004, Diabetes care.

[4]  H. M. Heise Technology for non-invasive monitoring of glucose , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  Gerard L. Cot,et al.  Application of a multivariate technique to Raman spectra for quantification of body chemicals , 1995, IEEE Transactions on Biomedical Engineering.

[6]  Huiquan Wang,et al.  Noninvasive blood glucose sensing by near-infrared spectroscopy based on PLSR combines SAE deep neural network approach , 2021 .

[7]  D. F. Swinehart,et al.  The Beer-Lambert Law , 1962 .

[8]  W. March,et al.  Noninvasive Glucose Monitoring of the Aqueous Humor of the Eye: Part I. Measurement of Very Small Optical Rotations , 1982, Diabetes Care.

[9]  Ksenia Tonyushkina,et al.  Glucose Meters: A Review of Technical Challenges to Obtaining Accurate Results , 2009, Journal of diabetes science and technology.

[10]  M. Benaissa,et al.  Digital bandstop filtering in the quantitative analysis of glucose from near‐infrared and midinfrared spectra , 2020 .

[11]  D. Cox,et al.  Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose , 1987, Diabetes Care.

[12]  Ming-Hsun Wu,et al.  Accuracy and precision evaluation of seven self-monitoring blood glucose systems. , 2011, Diabetes technology & therapeutics.

[13]  Raphael A. Viscarra Rossel,et al.  ParLeS: Software for chemometric analysis of spectroscopic data , 2008 .

[14]  Wouter Saeys,et al.  Selection of the most informative near infrared spectroscopy wavebands for continuous glucose monitoring in human serum. , 2016, Talanta.

[15]  F.M. Ham,et al.  Determination of glucose concentrations in an aqueous matrix from NIR spectra using optimal time-domain filtering and partial least-squares regression , 1997, IEEE Transactions on Biomedical Engineering.

[16]  Hoi-Jun Yoo,et al.  An Impedance and Multi-Wavelength Near-Infrared Spectroscopy IC for Non-Invasive Blood Glucose Estimation , 2015, IEEE Journal of Solid-State Circuits.