Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis

Background and purpose Little is known about the long-term outcome of cemented metal-on-metal hip arthroplasties. We evaluated a consecutive series of metal-on-metal polyethylene-backed cemented hip arthroplasties implanted in patients under 60 years of age. Methods 109 patients (134 joint replacements) were followed prospectively for mean 9 (7–11) years. The evaluation included clinical score, radiographic assessment, and blood sampling for ion level determination. Results At the final review, 12 hips had been revised, mainly because of aseptic loosening of the socket. Using revision for aseptic loosening as the endpoint, the survival rate at 9 years was 91% for the cup and 99% for the stem. In addition, 35 hips showed radiolucent lines at the bone-cement interface of the acetabulum and some were associated with osteolysis. The median serum cobalt and chromium levels were relatively constant over time, and were much higher than the detection level throughout the study period. The cobalt level was 1.5 μg/L 1 year after implantation, and 1.44 μg/L 9 years after implantation. Interpretation Revisions for aseptic loosening and radiographic findings in the sockets led us to halt metal-on-metal-backed polyethylene cemented hip arthroplasty procedures. If the rigidity of the cemented socket is a reason for loosening, excessive release of metal ions and particles may be involved. Further investigations are required to confirm this hypothesis and to determine whether subluxation, microseparation, and hypersensitivity also play a role.

[1]  P. Ravaud,et al.  Clinical and biological assessment of cemented titanium femoral stems: an 11-year experience , 2009, International Orthopaedics.

[2]  G. Heinze,et al.  Long‐term follow‐up of metal‐on‐metal total hip replacement , 2007, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  John Fisher,et al.  Characterisation of wear particles produced by metal on metal and ceramic on metal hip prostheses under standard and microseparation simulation , 2007, Journal of materials science. Materials in medicine.

[4]  Masahiko Watanabe,et al.  Midterm results of Metasul metal-on-metal total hip arthroplasty. , 2006, The Journal of arthroplasty.

[5]  S. Descamps,et al.  Échec par descellement aseptique précoce de la cupule acétabulaire cimentée de prothèses totales de hanche à couple de frottement métal-métal , 2006 .

[6]  C. Ranawat,et al.  Serum metal levels and bearing surfaces in total hip arthroplasty. , 2006, The Journal of arthroplasty.

[7]  B. Augereau,et al.  [Metal-metal-backed polyethylene cemented hip arthroplasty: mid-term results]. , 2006, Revue de chirurgie orthopedique et reparatrice de l'appareil moteur.

[8]  C. Case,et al.  Biological effects of metal-on-metal hip replacements , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[9]  D Dowson,et al.  Understanding the role of corrosion in the degradation of metal-on-metal implants , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[10]  P. Campbell,et al.  Wear particles from metal-on-metal total hip replacements: Effects of implant design and implantation time , 2006, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[11]  S. Descamps,et al.  [Early aseptic loosening of cemented cup in metal-on-metal total hip arthroplasties]. , 2006, Revue de chirurgie orthopedique et reparatrice de l'appareil moteur.

[12]  J. Fisher,et al.  Effect of swing phase load on metal-on-metal hip lubrication, friction and wear. , 2006, Journal of biomechanics.

[13]  Seung-Jae Lim,et al.  Early osteolysis following second-generation metal-on-metal hip replacement. , 2005, The Journal of bone and joint surgery. American volume.

[14]  C. Rieker,et al.  Development and validation of a second-generation metal-on-metal bearing: laboratory studies and analysis of retrievals. , 2004, The Journal of arthroplasty.

[15]  John B Medley,et al.  Comparison of in vitro with in vivo characteristics of wear particles from metal-metal hip implants. , 2004, Journal of biomedical materials research. Part B, Applied biomaterials.

[16]  L. Sedel,et al.  Long-Term Results of Alumina-on-Alumina Hip Arthroplasty for Osteonecrosis , 2003, Clinical orthopaedics and related research.

[17]  A. Kaider,et al.  Serum cobalt levels after metal-on-metal total hip arthroplasty. , 2003, The Journal of bone and joint surgery. American volume.

[18]  P. Herberts,et al.  The Swedish Total Hip Replacement Register , 2002, The Journal of bone and joint surgery. American volume.

[19]  K. Mikecz,et al.  Differential lymphocyte reactivity to serum-derived metal-protein complexes produced from cobalt-based and titanium-based implant alloy degradation. , 2001, Journal of biomedical materials research.

[20]  R. Ganz,et al.  Osteolysis in cemented titanium alloy hip prosthesis. , 2000, The Journal of arthroplasty.

[21]  P. Devane,et al.  Assessment of polyethylene wear in total hip replacement. , 1999, Clinical orthopaedics and related research.

[22]  R. Schenk,et al.  Wear Behavior and Histopathology of Classic Cemented Metal on Metal Hip Endoprostheses , 1996, Clinical orthopaedics and related research.

[23]  B. Weber Experience With the Metasul Total Hip Bearing System , 1996, Clinical orthopaedics and related research.

[24]  D Dowson,et al.  Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. , 1996, The Journal of bone and joint surgery. British volume.

[25]  D. Howie,et al.  The differences in toxicity and release of bone-resorbing mediators induced by titanium and cobalt-chromium-alloy wear particles. , 1993, The Journal of bone and joint surgery. American volume.