DynaCT-Guided Anatomical Rotation of the SAPIEN XT Valve during Transapical Aortic Valve Implantation: Proof of Concept

Abstract Background Transcatheter aortic valve implantation (T-AVI) by using the Edwards SAPIEN (Edwards Lifesciences LLC, Irvine, California, United States) prosthesis is currently being performed by the implantation of valved stent into the aortic annulus without respecting the native commissural (rotational) orientation. Anatomical orientation may, however, be beneficial regarding optimal physiological valve performance, optimal coronary flow, and avoidance of the fully covered commissural stent part in front of the coronary ostia. With the recently introduced SAPIEN XT, transcatheter valve identification of the commissures during fluoroscopy is feasible. The aim of this study was to evaluate the concept of Dynamic-CT (DynaCT)–guided anatomical rotation of the SAPIEN XT valve during transapical-AVI (TA-AVI). Methods Intraoperatively, an automatically segmented DynaCT was performed using the Siemens Syngo Aortic ValveGuide (Siemens AG, Forchheim, Germany) software prototype. Commissures of SAPIEN XT could be identified with a high-quality fluoroscopic system. Before standard TA implantation, one radiopaque stent commissure of the crimped SAPIEN XT prosthesis was aligned with the native aortic valve commissure visualized by DynaCT. Resulting rotational orientation of the valve after implantation was assessed by transesophageal echocardiography. Results Feasibility of anatomical rotation was evaluated in 10 patients scheduled for TA-AVI by an interdisciplinary heart team. Mean logistic EuroSCOREs and Society of Thoracic Surgeons scores were 23.7 ± 4.9% and 8.6 ± 2.1%, mean aortic gradient improved from 46.0 ± 21.9 to 9.6 ± 3.1 mm Hg, and there was no death within 30 days. All valves were implanted successfully with none or trivial paravalvular regurgitation in seven patients, mild (1 + ) in two patients, and moderate (2 + ) in one patient. An optimal anatomical position could be achieved in six patients, minor rotational deviation (< 10 degrees) in three patients, and moderate deviation (10 to 20 degrees) in one patient only. Conclusions DynaCT-guided anatomical rotation of the SAPIEN XT valve is feasible during TA-AVI, avoiding implantation of the fully covered commissural posts in front of the coronary ostia. This might reduce the risk of coronary obstruction. In addition, the technique provides the potential benefit of physiological valve position and performance.

[1]  Andreas Beckmann,et al.  Cardiac Surgery in Germany during 2011: A Report on Behalf of the German Society for Thoracic and Cardiovascular Surgery , 2012, Thoracic and Cardiovascular Surgeon.

[2]  J. Rodés‐Cabau,et al.  First‐in‐man transcatheter aortic valve implantation of a 20‐mm edwards SAPIEN XT valve: One step forward for the treatment of patients with severe aortic stenosis and small aortic annulus , 2012, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[3]  G. Hasenfuss,et al.  The risk-to-benefit ratio of transcatheter aortic valve implantation in specific patient cohorts: a single-centre experience , 2012, Clinical Research in Cardiology.

[4]  F. Mohr,et al.  Automatically segmented DynaCT: enhanced imaging during transcatheter aortic valve implantation. , 2011, Journal of the American College of Cardiology.

[5]  G. Schuler,et al.  Trans-apical aortic valve implantation using a new self-expandable bioprosthesis: initial outcomes. , 2011, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[6]  F. Mohr,et al.  A new self-expanding transcatheter aortic valve for transapical implantation - first in man implantation of the JenaValve™. , 2011, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[7]  Stuart J Pocock,et al.  Transcatheter versus surgical aortic-valve replacement in high-risk patients. , 2011, The New England journal of medicine.

[8]  R. Erbel,et al.  Transcatheter aortic valve implantation: evidence on safety and efficacy compared with medical therapy. A systematic review of current literature , 2011, Clinical Research in Cardiology.

[9]  T. Walther,et al.  Transcatheter aortic valve implantation transapical: step by step. , 2011, Seminars in thoracic and cardiovascular surgery.

[10]  A. Moritz,et al.  Effect of mechanical aortic valve orientation on coronary artery flow: comparison of tilting disc versus bileaflet prostheses in pigs. , 2002, The Journal of thoracic and cardiovascular surgery.