Geometric calibration method for multiple heads cone-beam SPECT system

A method is presented for estimating the geometrical parameters of cone beam systems with multiple heads, each head having its own orientation. In tomography, for each head, the relative position of the rotation axis and of the collimator do not change during the data acquisition. One thus can separate the parameters into intrinsic parameters and extrinsic parameters. The intrinsic parameters describe the detection system geometry and the extrinsic parameters the position of the detection system with respect to the rotation axis. Intrinsic parameters are measured directly, once for each collimator. Extrinsic parameters must be estimated each time the acquisition geometry is modified. Extrinsic parameters are estimated by minimizing the distances between the measured position of a point source projection and the computed position obtained using the estimated extrinsic parameters. The main advantage of this method is that the extrinsic parameters are only weakly correlated when the intrinsic parameters are known. Thus one can use any simple least square error minimization method to perform the estimation of the extrinsic parameters. Giving a fixed value to the distance between the point source and the rotation axis in the estimation process, ensures the coherence of the extrinsic parameters between each head. The authors show that, with this calibration method, the full width at half maximum measured with point sources is very close to the theoretical one, and remains almost unchanged when more than one head is used. Simulation results and reconstructions on a Jaszczak phantom are presented that show the capabilities of this method. >

[1]  E. Busemann-Sokole Measurement of collimator hole angulation and camera head tilt for slant and parallel hole collimators used in SPECT. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  P. Grangeat Mathematical framework of cone beam 3D reconstruction via the first derivative of the radon transform , 1991 .

[3]  Carl R. Crawford,et al.  Reconstruction Algorithm for Fan Beam with a Displaced Center-of-Rotation , 1986, IEEE Transactions on Medical Imaging.

[4]  Benjamin M. W. Tsui,et al.  Estimation of geometrical parameters for fan beam tomography , 1987 .

[5]  J. Fitch,et al.  Calculation of the rotational centers in computed tomography sinograms , 1990 .

[6]  Pierre Grangeat,et al.  Cone-beam spelt with a tilted detector , 1993 .

[7]  G T Gullberg,et al.  Estimation of geometrical parameters and collimator evaluation for cone beam tomography. , 1990, Medical physics.

[8]  R. Jaszczak,et al.  Cone beam collimation for single photon emission computed tomography: analysis, simulation, and image reconstruction using filtered backprojection. , 1986, Medical physics.

[9]  Michael E. Phelps,et al.  Physics in nuclear medicine. Second edition , 1987 .

[10]  William H. Press,et al.  Numerical Recipes in FORTRAN - The Art of Scientific Computing, 2nd Edition , 1987 .

[11]  William H. Press,et al.  The Art of Scientific Computing Second Edition , 1998 .

[12]  R J Jaszczak,et al.  Determination of both mechanical and electronic shifts in cone beam SPECT. , 1993, Physics in medicine and biology.

[13]  Y. Trousset,et al.  Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction. , 1993, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[14]  Pascal Sire,et al.  “Vision” Approach of Calibration Methods for Radiographic Systems , 1993 .