Fast escape of hydrogen from gas cavities around corroding magnesium implants.

Magnesium materials are of increasing interest in the development of biodegradable implants as they exhibit properties that make them promising candidates. However, the formation of gas cavities after implantation of magnesium alloys has been widely reported in the literature. The composition of the gas and the concentration of its components in these cavities are not known as only a few studies using non-specific techniques were done about 60 years ago. Currently many researchers assume that these cavities contain primarily hydrogen because it is a product of magnesium corrosion in aqueous media. In order to clearly answer this question we implanted rare earth-containing magnesium alloy disks in mice and determined the concentration of hydrogen gas for up to 10 days using an amperometric hydrogen sensor and mass spectrometric measurements. We were able to directly monitor the hydrogen concentration over a period of 10 days and show that the gas cavities contained only a low concentration of hydrogen gas, even shortly after formation of the cavities. This means that hydrogen must be exchanged very quickly after implantation. To confirm these results hydrogen gas was directly injected subcutaneously. Most of the hydrogen gas was found to exchange within 1h after injection. Overall, our results disprove the common misbelief that these cavities mainly contain hydrogen and show how quickly this gas is exchanged with the surrounding tissue.

[1]  A. F. Holleman,et al.  Lehrbuch der anorganischen Chemie , 2010, Nature.

[2]  Alan G. Wikoff CHEMICAL AND METALLURGICAL ENGINEERING , 1923 .

[3]  J. Prendergast,et al.  Chemical gas gangrene from metallic magnesium , 1942 .

[4]  Frank Witte,et al.  Degradable biomaterials based on magnesium corrosion , 2008 .

[5]  Norman L. Guinasso,et al.  Equilibrium Solubilities of Methane, Carbon Monoxide, and Hydrogen in Water and Sea Water, , 1979 .

[6]  Andrej Atrens,et al.  Corrosion of high purity Mg, AZ91, ZE41 and Mg2Zn0.2Mn in Hank’s solution at room temperature , 2011 .

[7]  Yufeng Zheng,et al.  The development of binary Mg-Ca alloys for use as biodegradable materials within bone. , 2008, Biomaterials.

[8]  S. Kety The theory and applications of the exchange of inert gas at the lungs and tissues. , 1951, Pharmacological reviews.

[9]  M. Liu,et al.  The influence of yttrium (Y) on the corrosion of Mg–Y binary alloys , 2010 .

[10]  Guang-Ling Song,et al.  Control of biodegradation of biocompatable magnesium alloys , 2007 .

[11]  F. Wittea,et al.  In vivo corrosion of four magnesium alloys and the associated bone response , 2004 .

[12]  E. L. Green,et al.  Biology of the Laboratory Mouse , 1942 .

[13]  N E Saris,et al.  Magnesium. An update on physiological, clinical and analytical aspects. , 2000, Clinica chimica acta; international journal of clinical chemistry.

[14]  D. Kusewitt,et al.  The hairless mouse in skin research. , 2009, Journal of dermatological science.

[15]  Philippe Poitras,et al.  Internal plate fixation of fractures: short history and recent developments , 2006, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[16]  E. Mcbride,et al.  ABSORBABLE METAL IN BONE SURGERY: A FURTHER REPORT ON THE USE OF MAGNESIUM ALLOYS , 1938 .

[17]  O. Duygulu,et al.  The effects of magnesium particles in posterolateral spinal fusion: an experimental in vivo study in a sheep model. , 2007, Journal of neurosurgery. Spine.

[18]  G. Song,et al.  Understanding Magnesium Corrosion—A Framework for Improved Alloy Performance , 2003 .

[19]  G. Song,et al.  Corrosion mechanisms of magnesium alloys , 1999 .

[20]  Raimund Erbel,et al.  Drug-eluting bioabsorbable magnesium stent. , 2004, Journal of interventional cardiology.

[21]  J. Nellesen,et al.  Cartilage repair on magnesium scaffolds used as a subchondral bone replacement , 2006 .

[22]  Yang Song,et al.  Research on an Mg-Zn alloy as a degradable biomaterial. , 2010, Acta biomaterialia.

[23]  H. Stegall,et al.  Solubility of gases in human red blood cell ghosts. , 1970, Journal of applied physiology.

[24]  F. Poitrasson,et al.  Experimental determination of synthetic NdPO4 monazite end-member solubility in water from 21°C to 300°C: implications for rare earth element mobility in crustal fluids , 2004 .

[25]  K. Kainer,et al.  Magnesium Permanent Mold Castings Optimization , 2011 .

[26]  Y. Li,et al.  Passivity behavior of melt-spun Mg–Y Alloys , 2003 .

[27]  D. V. Slyke,et al.  STUDIES OF GAS AND ELECTROLYTE EQUILIBRIA IN BLOOD XI. THE SOLUBILITY OF HYDROGEN AT 38° IN BLOOD SERUM AND CELLS , 1928 .

[28]  Alexis M Pietak,et al.  Magnesium and its alloys as orthopedic biomaterials: a review. , 2006, Biomaterials.

[29]  A. Bishop,et al.  Measurement of bone blood flow using the hydrogen washout Technique—Part I: Quantitative evaluation of tissue perfusion in the laboratory rat , 2008, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[30]  C. M. Agrawal Reconstructing the human body using biomaterials , 1998 .

[31]  Frank Witte,et al.  Progress and Challenge for Magnesium Alloys as Biomaterials , 2008 .

[32]  Andrea Meyer-Lindenberg,et al.  Evaluation of the soft tissue biocompatibility of MgCa0.8 and surgical steel 316L in vivo: a comparative study in rabbits , 2010, Biomedical engineering online.

[33]  G. Blanco,et al.  Chemical Reactivity of Binary Rare Earth Oxides , 2004 .

[34]  B. Denkena,et al.  Influence of Different Surface Machining Treatments of Magnesium‐based Resorbable Implants on the Degradation Behavior in Rabbits , 2009 .

[35]  M. Störmer,et al.  Magnesium alloys as implant materials--principles of property design for Mg-RE alloys. , 2010, Acta biomaterialia.

[36]  G. Song Recent Progress in Corrosion and Protection of Magnesium Alloys , 2005 .