Fractures of Corin 'Taper-Fit' CDH stems used in 'cement-in-cement' revision total hip replacement.

We describe two cases of fracture of Corin Taper-Fit stems used for cement-in-cement revision of congenital dysplasia of the hip. Both prostheses were implanted in patients in their 50s, with high offsets (+7.5 mm and +3.5 mm), one with a large diameter (48 mm) head and one with a constrained acetabular component. Fracture of the stems took place at nine months and three years post-operatively following low-demand activity. Both fractures occurred at the most medial of the two stem introducer holes in the neck of the prosthesis, a design feature that is unique to the Taper-Fit stem. We would urge caution in the use of these particular stems for cement-in-cement revisions.

[1]  A. Timperley,et al.  RESULTS OF IN-CEMENT REVISION OF INFECTED TOTAL HIP ARTHROPLASTY , 2008 .

[2]  A. Pankaj In-cement technique for revision hip arthroplasty. , 2006, The Journal of bone and joint surgery. British volume.

[3]  C. Nelson Cemented femoral revision: technique and outcome. , 2002, American journal of orthopedics.

[4]  W. F. Deans,et al.  Hip joint prosthesis design: effect of stem introducers. , 1998, Medical engineering & physics.

[5]  C. Ranawat,et al.  Cement-within-cement revision hip arthroplasty. , 1993, The Journal of bone and joint surgery. British volume.

[6]  W. Macdonald,et al.  Revision of Cemented Fixation and Cement—Bone Interface Strength , 1992, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.