Noise in the ED.

BACKGROUND The impact of noise pollution on both the patient and the care provider has been extensively studied in the neonatal intensive care unit and in other critical care units. Noise pollution makes errors more probable and is one of the risk factors for provider burnout and negative outcomes for patients. The Environmental Protection Agency (EPA) recommends that the acceptable noise level in a hospital should not exceed 40 dB. OBJECTIVES The purpose of this study was to record and analyze noise in a large urban level I emergency department (ED) and compare to the EPA guidelines. METHODS A 3-channel dosimeter Quest Q300 (Quest Technologies, Oconomowoc, WI) was placed as a stand-alone unit on the wall of the resuscitation booth in the ED. Sound was sampled 16 times per second for 12 hours and was recorded as peaks and averages for each minute. The dosimeter was then placed in the pocket of a medical student with a small 8-mm shoulder-mount type 2 microphone. The medical student followed an emergency medicine resident throughout an 8-hour shift in the main resuscitation area while monitoring and logging sound fluctuations in the environment. Sound pressure levels were logged in real time and subsequently correlated to the recorded peaks. Sound was sampled 16 times per second and recorded peaks and averages for each minute. RESULTS In the initial part of the study, the time-weighted average was 43 dB. The average sound levels peaked approximately 25 times over 12 hours. Individually measured peak levels of 94 to 117 dB occurred every minute. In the second part of the study, the time-weighted average was 52.9 dB. CONCLUSIONS When compared to EPA accepted noise levels for hospital (40 dB), the ED under study had excessive noise on a regular basis. There are easily identifiable sources of noise pollution in the ED. By identifying and modifying sources of noise, stress in the ED may be decreased.

[1]  R. Millman,et al.  Identification and modification of environmental noise in an ICU setting. , 1998, Chest.

[2]  C. Weigle,et al.  Use of active noise cancellation devices in caregivers in the intensive care unit , 2000, Critical care medicine.

[3]  W. Mallon,et al.  A survey of wellness issues in emergency medicine (Part I). , 1995, Annals of emergency medicine.

[4]  T W Whitley,et al.  Factors associated with stress among emergency medicine residents. , 1989, Annals of emergency medicine.

[5]  D. Revicki,et al.  A study of occupational stress and depression among emergency physicians. , 1992, Annals of emergency medicine.

[6]  L. Forst,et al.  The occupational hazards of emergency physicians. , 2000, The American journal of emergency medicine.

[7]  L. Zun,et al.  Practice satisfaction, occupational stress, and attrition of emergency physicians. Wellness Task Force, Illinois College of Emergency Physicians. , 1995, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[8]  Yoel Donchin,et al.  The hostile environment of the intensive care unit , 2002, Current opinion in critical care.

[9]  V. Markovchick,et al.  Wellness issues and the emergency medicine resident. , 2000, Annals of emergency medicine.

[10]  B. Walder,et al.  Effects of guidelines implementation in a surgical intensive care unit to control nighttime light and noise levels , 2000, Critical care medicine.

[11]  A. Robertson,et al.  Peak noise distribution in the neonatal intensive care nursery. , 1998, Journal of perinatology : official journal of the California Perinatal Association.