In vivo three-dimensional photoacoustic imaging based on a clinical matrix array ultrasound probe.

We present an integrated photoacoustic and ultrasonic three-dimensional (3-D) volumetric imaging system based on a two-dimensional (2-D) matrix array ultrasound probe. A wavelength-tunable dye laser pumped by a Q-switched Nd:YAG laser serves as the light source and a modified commercial ultrasound imaging system (iU22, Philips Healthcare) with a 2-D array transducer (X7-2, Philips Healthcare) detects both the pulse-echo ultrasound and photoacoustic signals. A multichannel data acquisition system acquires the RF channel data. The imaging system enables rendering of co-registered 3-D ultrasound and photoacoustic images without mechanical scanning. The resolution along the azimuth, elevation, and axial direction are measured to be 0.69, 0.90 and 0.84 mm for photoacoustic imaging. In vivo 3-D photoacoustic mapping of the sentinel lymph node was demonstrated in a rat model using methylene blue dye. These results highlight the clinical potential of 3-D PA imaging for identification of sentinel lymph nodes for cancer staging in humans.

[1]  Robert A Kruger,et al.  Photoacoustic angiography of the breast. , 2010, Medical physics.

[2]  Lihong V. Wang,et al.  Universal back-projection algorithm for photoacoustic computed tomography. , 2005 .

[3]  F. M. van den Engh,et al.  Initial results of in vivo non-invasive cancer imaging in the human breast using near-infrared photoacoustics. , 2007, Optics express.

[4]  Todd N. Erpelding,et al.  Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system , 2010, Biomedical optics express.

[5]  Arkadiusz Sitek,et al.  Feasibility of measurement of pancreatic perfusion parameters with single-compartment kinetic model applied to dynamic contrast-enhanced CT images. , 2008, Radiology.

[6]  Wei Wang,et al.  Simultaneous Molecular and Hypoxia Imaging of Brain Tumors In Vivo Using Spectroscopic Photoacoustic Tomography , 2008, Proceedings of the IEEE.

[7]  P. Soares-da-Silva,et al.  Uptake and intracellular fate of L-DOPA in a human intestinal epithelial cell line: Caco-2. , 1998, The American journal of physiology.

[8]  Wiendelt Steenbergen,et al.  Photoacoustic mammography laboratory prototype: imaging of breast tissue phantoms. , 2004, Journal of biomedical optics.

[9]  R. Dhillon,et al.  For the safe use of lasers , 1989 .

[10]  Vasilis Ntziachristos,et al.  Real-time imaging of cardiovascular dynamics and circulating gold nanorods with multispectral optoacoustic tomography. , 2010, Optics express.

[11]  Lihong V. Wang,et al.  Noninvasive photoacoustic identification of sentinel lymph nodes containing methylene blue in vivo in a rat model. , 2008, Journal of biomedical optics.

[12]  Lihong V. Wang,et al.  Noninvasive, in vivo imaging of blood-oxygenation dynamics within the mouse brain using photoacoustic microscopy. , 2009, Journal of biomedical optics.

[13]  Fred P. Seeber,et al.  OP-TEC national center for optics and photonics education and ANSI Z136.5 American National Standard for the safe use of lasers in educational institutions – How they will work together to improve laser safety in educational institutions , 2009 .

[14]  Lihong V. Wang Multiscale photoacoustic microscopy and computed tomography. , 2009, Nature photonics.

[15]  Geng Ku,et al.  Noninvasive imaging of hemoglobin concentration and oxygenation in the rat brain using high-resolution photoacoustic tomography. , 2006, Journal of biomedical optics.

[16]  B T Cox,et al.  k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields. , 2010, Journal of biomedical optics.

[17]  D. Weaver,et al.  Surgical resection and radiolocalization of the sentinel lymph node in breast cancer using a gamma probe. , 1993, Surgical oncology.

[18]  Mary J. Nissen,et al.  Comparison of side effects between sentinel lymph node and axillary lymph node dissection for breast cancer , 2002, Annals of Surgical Oncology.

[19]  Liang Song,et al.  Multifocal optical-resolution photoacoustic microscopy in vivo. , 2011, Optics letters.

[20]  Richard Su,et al.  Whole-body three-dimensional optoacoustic tomography system for small animals. , 2009, Journal of biomedical optics.

[21]  Yu Zhang,et al.  Fiber-laser-based photoacoustic microscopy and melanoma cell detection. , 2011, Journal of biomedical optics.

[22]  Aya Kamaya,et al.  Three-dimensional photoacoustic imaging using a two-dimensional CMUT array , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[23]  Molly Brewer,et al.  Coregistered three-dimensional ultrasound and photoacoustic imaging system for ovarian tissue characterization. , 2009, Journal of biomedical optics.

[24]  C. Patlak,et al.  A compartmental analysis of 24Na kinetics in rat cerebrum, sciatic nerve and cerebrospinal fluid , 1972 .

[25]  Manojit Pramanik,et al.  Sentinel lymph nodes in the rat: noninvasive photoacoustic and US imaging with a clinical US system. , 2010, Radiology.