Long-term effect of surface light scattering and glistenings of intraocular lenses on visual function.

PURPOSE To investigate the long-term effect of surface light scattering and glistenings of various intraocular lenses (IOLs) on visual function and optical aberrations after cataract surgery. DESIGN Case-control study. METHODS Thirty-five eyes that underwent implantation of a hydrophobic acrylic, silicone, or polymethyl methacrylate (PMMA) IOL more than 10 years ago were recruited. The scattering light intensity of the surface and internal matrix of the optic was measured using Scheimpflug photography. Visual acuity (VA) was measured using VA charts, and contrast VA and that with glare (glare VA) were examined using a contrast sensitivity tester. Ocular higher-order aberrations (HOAs) were measured using a Hartmann-Shack aberrometer. RESULTS Mean scattering light intensity of the surface and internal matrix of the optic was significantly higher in the acrylic group than in the silicone and PMMA groups (P < .0001). Mean uncorrected VA, photopic and mesopic contrast VA and glare VA, and HOAs did not differ significantly among groups, although mean corrected VA in the acrylic group was significantly better than that in the other groups (P = .0023). Scattering light intensity of the surface and internal matrix did not correlate with VA, contrast VA, or glare VA, and did not correlate with ocular and internal optic HOAs in the acrylic group. CONCLUSIONS At more than 10 years postoperatively, visual function, including contrast sensitivity, and ocular HOAs were comparable among eyes that received acrylic, silicone, and PMMA IOLs. Surface scattering and glistenings with the acrylic IOLs were not significantly correlated with visual function and optical aberrations.

[1]  K. Sugiyama,et al.  Early opacification of a single-piece hydrophobic acrylic intraocular lens after a triple procedure. , 2007, Journal of cataract and refractive surgery.

[2]  S. Yaguchi,et al.  Equilibrium water content and glistenings in acrylic intraocular lenses , 2004, Journal of cataract and refractive surgery.

[3]  K. Miyata,et al.  Comparison of postoperative surface light scattering of different intraocular lenses , 2009, British Journal of Ophthalmology.

[4]  N. Mamalis,et al.  In vitro analysis of AcrySof intraocular lens glistenings in AcryPak and Wagon Wheel packaging , 1998, Journal of cataract and refractive surgery.

[5]  S. Yaguchi,et al.  Clinical and experimental observation of glistening in acrylic intraocular lenses. , 2001, Japanese journal of ophthalmology.

[6]  H. Hayashi,et al.  Posterior capsule opacification in the presence of an intraocular lens with a sharp versus rounded optic edge. , 2005, Ophthalmology.

[7]  A. Behndig,et al.  Quantification of glistenings in intraocular lenses using Scheimpflug photography , 2009, Journal of cataract and refractive surgery.

[8]  T. Oshika,et al.  Fourier analysis of irregular astigmatism after implantation of 3 types of intraocular lenses , 2000, Journal of cataract and refractive surgery.

[9]  Randall J. Olson,et al.  Visual significance of glistenings seen in the AcrySof intraocular lens , 1996, Journal of cataract and refractive surgery.

[10]  R. Olson,et al.  Glistenings in the AcrySof intraocular lens: pilot study , 2001, Journal of cataract and refractive surgery.

[11]  T. Senoo,et al.  Clinical evaluation of the transparency of hydrophobic acrylic intraocular lens optics , 2010, Journal of cataract and refractive surgery.

[12]  S. Barman,et al.  Relationship between intraocular lens biomaterials and posterior capsule opacification , 1998, Journal of cataract and refractive surgery.

[13]  D. Apple,et al.  Light scatter on the surface of AcrySof intraocular lenses: part I. Analysis of lenses retrieved from pseudophakic postmortem human eyes. , 2008, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[14]  P. Artal,et al.  Compensation of corneal aberrations by the internal optics in the human eye. , 2001, Journal of vision.

[15]  Xiaoming Chen,et al.  Effect of AcrySof versus silicone or polymethyl methacrylate intraocular lens on posterior capsule opacification. , 2008, Ophthalmology.

[16]  Lorenz Vock,et al.  Posterior capsule opacification and neodymium:YAG laser capsulotomy rates with a round‐edged silicone and a sharp‐edged hydrophobic acrylic intraocular lens 10 years after surgery , 2009, Journal of cataract and refractive surgery.

[17]  Liliana Werner,et al.  Glistenings and surface light scattering in intraocular lenses , 2010, Journal of cataract and refractive surgery.

[18]  H. Hayashi,et al.  Changes in posterior capsule opacification after poly(methyl methacrylate), silicone, and acrylic intraocular lens implantation , 2001, Journal of cataract and refractive surgery.

[19]  S. Sacu,et al.  Posterior capsule opacification in silicone and hydrophobic acrylic intraocular lenses with sharp-edge optics six years after surgery. , 2009, American journal of ophthalmology.

[20]  Randall J Olson,et al.  In vitro comparison of glistening formation among hydrophobic acrylic intraocular lenses , 2002 .

[21]  J. Storsberg,et al.  Unusual pattern of glistening formation on a 3-piece hydrophobic acrylic intraocular lens. , 2008, Journal of cataract and refractive surgery.

[22]  Yasuhiko Shiokawa,et al.  Influence of glistenings on the optical quality of acrylic foldable intraocular lens , 2001, The British journal of ophthalmology.

[23]  M. Ayaki,et al.  Surface scattering in implanted hydrophobic intraocular lenses , 2003, Journal of cataract and refractive surgery.

[24]  Sergio Barbero,et al.  Optical aberrations of intraocular lenses measured in vivo and in vitro. , 2003, Journal of the Optical Society of America. A, Optics, image science, and vision.

[25]  K. Nakamae,et al.  Glistening formation in an AcrySof lens initiated by spinodal decompositionof the polymer network bytemperature change , 2001, Journal of cataract and refractive surgery.

[26]  H. Hayashi,et al.  Quantitative comparison of posterior capsule opacification after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation. , 1998, Archives of ophthalmology.

[27]  S. Barman,et al.  The effect of polymethylmethacrylate, silicone, and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery. , 1999, Ophthalmology.

[28]  H. Hayashi,et al.  Correlation of higher-order wavefront aberrations with visual function in pseudophakic eyes , 2008, Eye.

[29]  U. Gunenc,et al.  Effects on visual function of glistenings and folding marks in AcrySof intraocular lenses , 2001, Journal of cataract and refractive surgery.

[30]  C. Zetterström,et al.  Comparison of posterior capsule opacification development with 3 intraocular lens types: Five‐year prospective study , 2009, Journal of cataract and refractive surgery.

[31]  T. Senoo,et al.  Analysis of surface whitening of extracted hydrophobic acrylic intraocular lenses , 2009, Journal of cataract and refractive surgery.

[32]  Lisa Toto,et al.  Glistenings in foldable intraocular lenses , 2002, Journal of cataract and refractive surgery.

[33]  Yoshimichi Tanida,et al.  On Founding the Journal of Visualization , 1998 .

[34]  K. Nakamae,et al.  Optical and atomic force microscopy of an explanted AcrySof intraocular lens with glistenings , 2000, Journal of cataract and refractive surgery.

[35]  Yaguchi,et al.  Clinical and Experimental Observation of Glistening in Acrylic Intraocular Lenses. , 2000, Japanese journal of ophthalmology.

[36]  A. Crandall,et al.  Visual complaints associated with the AcrySof acrylic intraocular lens , 2000, Journal of cataract and refractive surgery.

[37]  R. Olson,et al.  Glistenings in the single-piece, hydrophobic, acrylic intraocular lenses. , 2007, American journal of ophthalmology.

[38]  H. Tsuneoka,et al.  In Vitro Analysis of AcrySof Intraocular Lens Glistening , 2003, European journal of ophthalmology.