Microfabricated flow system for ammonia and creatinine with an air-gap structure

A fast-responding Severinghaus-type ammonia gas-sensing electrode was developed by using an air gap formed in a flow channel. An electrolyte solution for the ammonia gas-sensing electrode was separated from a sample solution in the flow channel by an air gap maintained with a hydrophobic layer of silicone rubber intercalated between the electrode substrate and the flow channel. When a sample solution is introduced into the flow channel, ammonia dissipates through the air gap into the electrolyte solution. The accompanying pH change was measured with a thin-film pH-indicator electrode. Because of the air gap, the response was significantly faster than the electrodes of the conventional structure. The 90% response time was less than 1 min for an ammonia concentration higher than 1 mM. A linear relationship was observed in the calibration curve, and the lower detection limit was 20 μM. The ammonia electrode was used to construct a creatinine-sensing system. When the solution pH was 10.0, the lower detection limit was 50 μM, and the 90% response time was 4 min around the detection limit. The influence of endogenous ammonia could be minimized by taking a differential signal with a double indicator electrode structure. The signal originating from creatinine could be differentiated clearly in the presence of ammonia of comparable concentrations.

[1]  A. Killard,et al.  Creatinine biosensors: principles and designs. , 2000, Trends in biotechnology.

[2]  M. Meyerhoff,et al.  On-line gas dialyzer for automated enzymatic analysis with potentiometric ammonia detection. , 1983, Analytical chemistry.

[3]  PREPARATION OF AN OXIDIZED IRIDIUM ELECTRODE AND THE VARIATION OF ITS POTENTIAL WITH PH , 1984 .

[4]  Isao Karube,et al.  Problems associated with the thin-film Ag/AgCl reference electrode and a novel structure with improved durability , 1998 .

[5]  Stow Rw,et al.  Rapid measurement of the tension of carbon dioxide in blood. , 1957 .

[6]  J. Szulmajster BACTERIAL FERMENTATION OF CREATININE I , 1958, Journal of bacteriology.

[7]  M. Mascini,et al.  Ammonia abatement in an enzymatic flow system for the determination of creatinine in blood sera and urine , 1985 .

[8]  M. Meyerhoff,et al.  An activated enzyme electrode for creatinine. , 1976, Analytica chimica acta.

[9]  M. Hitchman,et al.  Evaluation of iridium oxide electrodes formed by potential cycling as pH probes. , 1988, The Analyst.

[10]  J. Ruzicka,et al.  Enzymatic analysis by means of the air-gap electrode determination of urea in blood. , 1974, Analytica chimica acta.

[11]  M. Mascini,et al.  Determination of creatinine in clinical samples with a creatininase reactor and an ammonia probe , 1982 .

[12]  Isao Karube,et al.  Microfabricated Liquid Junction Ag/AgCl Reference Electrode and Its Application to a One-Chip Potentiometric Sensor , 1999 .

[13]  J. Severinghaus,et al.  Electrodes for blood pO2 and pCO2 determination. , 1958, Journal of applied physiology.

[14]  Richard P. Buck,et al.  Microfabricated amperometric creatine and creatinine biosensors , 1996 .

[15]  C. Wolff,et al.  Immobilized enzyme electrode for creatinine determination in serum. , 1991, Analytical chemistry.

[16]  J. Joseph,et al.  An Enzyme microsensor for urea based on an ammonia gas electrode , 1985 .

[17]  J. Ruzicka,et al.  A new potentiometric gas sensor-the air-gap electrode , 1974 .

[18]  B. W. Wright,et al.  Rapid determination of ammonia in a perchloric acid supernate from blood, by use of an ammonia-specific electrode. , 1973, Clinical chemistry.

[19]  Hsuan‐Jung Huang,et al.  A creatinine deiminase modified polyaniline electrode for creatinine analysis , 1999 .

[20]  G. A. Rechnitz,et al.  Micro-size potentiometric probes for gas and substrate sensing , 1978 .

[21]  G. Guilbault,et al.  Creatinine-selective enzyme electrodes , 1983 .

[22]  K. Yoda,et al.  Multi-enzyme membrane electrodes for determination of creatinine and creatine in serum. , 1983, Clinical chemistry.

[23]  R. H. Robins,et al.  Disposable potentiometric ammonia gas sensors for estimation of ammonia in blood. , 1980, Analytical chemistry.

[24]  Hiroaki Suzuki,et al.  Advances in the Microfabrication of Electrochemical Sensors and Systems , 2000 .

[25]  J. A. Krueger,et al.  Potentiometric gas sensing electrodes , 1973 .

[26]  T. R. Gilbert,et al.  Determination of ammonia in aquaria and in sea water using the ammonia electrode , 1973 .

[27]  R. Barsotti Measurement of ammonia in blood. , 2001, The Journal of pediatrics.

[28]  A. Blum,et al.  High Concentrations of Ammonia, But Not Volatile Amines, in Gastric Juice of Subjects with Helicobacter pylori Infection , 1998, Helicobacter.

[29]  O. V. Yagodina,et al.  New potentiometric gas-gap sensor , 1999 .