Novel Sternal Protection Device for Cardiac Surgery Via Median Sternotomy Incision

Objective Sternal bleeding during cardiac surgery is currently controlled using bone wax or other chemical substances that may result in adverse effects and affect wound healing and recovery. The purpose of this study was to identify a safe, cost-effective, and easy-to-use technique to reduce sternal bleeding and sternal trauma during cardiac surgery. Methods After sternotomy, a sternal protection device was placed over each hemisternal section before insertion of the retractor and remained in situ until the end of surgery. Sternal bleeding and ease of use were assessed and recorded during surgery. Sternal trauma was assessed and recorded within 5 minutes of removal of the device, and overall satisfaction (Global Impression) and any intraoperative adverse events or device malfunction were reported at surgery completion. Patients were followed up 24 hours and 4 weeks after surgery. Results Twelve patients completed the study. Adverse events reported were not considered related to the device. No sternal trauma was identified in any patient. In 9 of 11 patients, sternal bleeding was reduced after insertion of the device. The device was generally considered easy to use, although some difficulty was encountered when used with the Internal Mammary Artery retractor. Conclusions Our data suggest that the device is safe and able to reduce sternal bleeding during surgery using sternal retractors. We recommend further studies in a larger population of patients with a control group to evaluate the device's ability to reduce the morbidity associated with sternal bleeding and sternal trauma.

[1]  Roman Gottardi,et al.  Sternal force distribution during median sternotomy retraction. , 2013, The Journal of thoracic and cardiovascular surgery.

[2]  T. Jakobsen,et al.  Bone healing after median sternotomy: A comparison of two hemostatic devices , 2010, Journal of cardiothoracic surgery.

[3]  R. Millner,et al.  A review of topical hemostatic agents for use in cardiac surgery. , 2009, The Annals of thoracic surgery.

[4]  Luca Ferretti,et al.  Cardiopulmonary bypass line sternal wrapping for protection and haemostasis. , 2009, Interactive cardiovascular and thoracic surgery.

[5]  Masha Kocherginsky,et al.  Tissue-disruptive forces during median sternotomy. , 2007, The heart surgery forum.

[6]  B. Reichart,et al.  Surgicel Nu-Knit hemostat for bleeding control of fragile sternum. , 2005, The Journal of thoracic and cardiovascular surgery.

[7]  D. Follette,et al.  Poststernotomy fractures and pain management in open cardiac surgery. , 1994, Chest.

[8]  Allison Rt Foreign body reactions and an associated histological artefact due to bone wax , 1994 .

[9]  D. Nelson,et al.  The promotional effect of bone wax on experimental Staphylococcus aureus osteomyelitis. , 1990, The Journal of thoracic and cardiovascular surgery.

[10]  Y. Yıldız,et al.  Sternal wrapping for the prevention of sternal morbidity in elderly osteoporotic patients undergoing median sternotomy. , 2011, Texas Heart Institute journal.

[11]  R. Allison Foreign body reactions and an associated histological artefact due to bone wax. , 1994, British journal of biomedical science.

[12]  P. Alberius,et al.  Effects of bone wax on rabbit cranial bone lesions. , 1987, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.